You are on page 1of 3

[1] EC-TYPE EXAMINATION CERTIFICATE

[2] Equipment or Protective System intended for use


e
in Potentially Explosive Atmospheres
Directive 94/9/EC

[3] EC-Type Examination Certificate Number: DEMKO 12 ATEX 1263925X Rev. 1


TM
[4] Equipment or Protective System: Acoustic Transmitter Model FlexSonic ATX10

[5] Manufacturer: Detector Electronics Corporation

[6] Address: 6901 West 110th Street, Minneapolis, MN 55 438, USA

[7] This equipment or protective system and any acceptable variation thereto are specified in the schedule to this certificate and the
documents therein referred to.

[8] UL International Demko A/S, notified body number 0539 in accordance with Article 9 of the Council Directive 94/9/EC of 23 March 1994,
certifies that this equipment or protective system has been found to comply with the Essential Health and Safety Requirements relating to
design and construction of equipment and protective systems intended for use in potentially explosive atmospheres given in Annex II to
the Directive.
The examination and test results are recorded in confidential report no. 13CA29626

[9] Compliance with the Essential Health and Safety Requirements has been assured by compliance with:

EN 60079-0:2012 EN 60079-1:2007 EN 60079-31:2009


[10] If the sign "X" is placed after the certificate number, it indicates that the equipment or protective system is subject to special conditions for
safe use specified in the schedule to this certificate.

[11] This EC-Type examination certificate relates only to the design, examination and tests of the specified equipment or protective system in
accordance to the Directive 94/9/EC. Further requirements of the Directive apply to the manufacturing process and supply of this
equipment or protective system.
These are not covered by the certificate.

[12] The marking of the equipment or protective system shall include the following:

e II 2 G Ex d IIC T6 Gb

e II 2 D Ex tb IIIC T80°C Db IP66

This is to certify that the sample(s) of the Product(s) described herein (“Certified Product”) has been investigated
and found in compliance with the Standard(s) indicated on this Certificate, in accordance with the ATEX
Certification Manager Equipment Certification Program Requirements. This certificate and test results obtained apply only to the
product sample(s) submitted by the Applicant. UL did not select the sample(s) or determine whether the
Jan-Erik Storgaard sample(s) provided were representative of other manufactured products. UL has not established Follow-Up
Service or other surveillance of the product. The Applicant/Manufacturer are solely and fully responsible for
conformity of all products to all applicable Standards, specifications, requirements or Directives. The test results
may not be used, in whole or in part, in any other document without UL’s prior written approval.

Date of issue: 2013-05-02


Revised: 2013-07-02

Notified Body UL International Demko A/S, Borupvang 5A, 2750 Ballerup, Denmark
Tel. +45 44 85 65 65, info.dk@ul.com
www.ul-europe.com

00-IC-F0056 – Issue 6.2 This certificate may only be reproduced in its entirety and without any change, schedule included. Page 1 of 3
[13] Schedule
[14] EC-TYPE EXAMINATION CERTIFICATE No.
DEMKO 12 ATEX 1263925X Rev. 1
Report: 13CA29626
[15] Description of Equipment
The function of the Acoustic Transmitter Model FlexSonicTM ATX10 is to evaluate the incoming acoustic power spectrum from the
Acoustic Detector model AC100, and make a determination of alarm condition.
The ATX10 consists of electronics housed in a cylindrical enclosure in type of explosion protection flameproof enclosure “d”,
manufactured from stainless steel. The flameproof enclosure base includes 2-6 cable entry ports and the cover includes a glass
window to view the status of the device.
The ATX10 is to be connected to the Acoustic Detector model AC100 and provides the industry standard 4-20mA signal w/HART and
LED indication for Normal Operation, Alarms and Faults.
Alternatively, the ATX10 can be connected remotely (max. 500 feet (152 m) cable length) to the Acoustic Detector model AC100
through the Stainless Steel Model STB Sensor Termination Box.
Furthermore, the ATX10 can be connected to the FlexView® Model UD10, using the UD10’s LCD display to provide the visual
indication for Normal Operation, Alarms and Faults.

The optical radiation output of the ATX10 with respect to explosion protection, according to Annex II clause 1.3.1 of the Directive
94/9/EC is covered in this certificate, since the ATX10 includes non-array indicator LEDs used to show equipment status.

Nomenclature for ATX10 abcde:


where
a = Enclosure material:
S = Stainless steel
b = Number of ports
2 = 2 Port*
3 = 3 Port*
4 = 4 Port*
5 = 5 Port (standard offering)
6 = 6 Port
c = Type of threaded locations:
N = ¾” NPT
M = M25
d = Output
26 = 4-20 mA w/HART Protocol
e = Approvals agency:
A = FM*/CSA*
B = INMETRO (Brasil)*
C = CSA*
E = ATEX/CE*/IECEx*
F = FM*
N = None*
R = VNIIFTRI (Russian)*
S = SIL*
T = SIL*/FM*/CSA*/ATEX/CE*/IECEx*
W = FM*/CSA*/ATEX/CE*/IECEx*
f = Port Configuration Code
* = Consult Factory for options

Notes:
1. The *-marked options are stated for information only and are not covered within this certification.
2. Type ‘Approvals’ can use one or more letters to designate the approval on the product.
3. See drawing 011821-001 for details.

Temperature range
The ambient temperature range is -55 °C to +75 °C.

Electrical data
Rated voltage 9-30Vdc (24Vdc nominal)
Rated power 1.75W max.
Output Signal 4-20mA with HART protocol

Installation instructions
All cable entry devices and blanking elements shall be certified in type of explosion protection flameproof enclosure “d”, suitable for the
conditions of use and correctly installed.

Unused apertures shall be closed with suitable flameproof certified blanking elements.

For ambient temperatures below –10 °C and above +60 °C use field wiring suitable for both minimum and maximum ambient
temperature.

The field wiring terminal connections are certified for a single wire in size from 0.2 to 2.5mm2, (or two conductors with same cross
section 0.2 to 0.75mm2). The screws must be tightened down with a torque of 0.4 to 0.5 Nm.

The metal housing must be electrically connected to earth ground.

00-IC-F0056 – Issue 6.2 This certificate may only be reproduced in its entirety and without any change, schedule included. Page 2 of 3
[13] Schedule
[14] EC-TYPE EXAMINATION CERTIFICATE No.
DEMKO 12 ATEX 1263925X Rev. 1
Report: 13CA29626
Mounting instructions
Please refer to the Instruction Manual.

Routine tests
Routine tests according to EN 60079-1 cl.16 are not required, as the enclosures have been successfully tested at four times the
reference pressure.

[16] Report No.


Project Report No.: 12CA63925 (Hazardous Location Testing)

Documents:
Description: Drawing No.: Rev. Level: Date:
Drw, Design Reference ATX10 ‘DEMKO’ (6 pages) 012114-001 D 2013-06-10
Multi Port J-box, SS. Mach. 008092-XXX K 2013-03-27
Short Window CVR SS (Mach) 011927-001 C 2013-02-20
Window, Soda Lime 006237-003 A 2013-01-28
Bracket Display Mount 011918-001 C 2013-02-20
Bracket Mount Extension 011926-001 C 2013-02-20
Bezel LED Display 011930-001 A 2012-11-14
Model # Matrix, ATX10 011821-001 A -
Instruction Manual AC100/ATX10 (34 pages) 95-8657 - 2013-06

[17] Special conditions for safe use:


The Acoustic Transmitter Model FlexSonicTM ATX10 is to be placed in an area where there is a low risk of mechanical damage.

[18] Essential Health and Safety Requirements


Concerning ESR this Schedule verifies compliance with the Annex III of ATEX directive only. The manufacturer's Declaration of
Conformity declares compliance with other relevant Directives.

Additional information
The Acoustic Transmitter Model FlexSonicTM ATX10 has in addition passed the tests for Ingress Protection to IP 66 in
accordance with EN60529:1991/A1 2001.

The manufacturer shall inform the notified body concerning all modifications to the technical documentation as described
in ANNEX III to Directive 94/9/EC of the European Parliament and the Council of 23 March 1994.

00-IC-F0056 – Issue 6.2 This certificate may only be reproduced in its entirety and without any change, schedule included. Page 3 of 3