You are on page 1of 17

SOFTWARE SUITES

PipeCAD
• Pipe
Pi M
Modeling
d li and
dVValidation
lid ti tool
t l
• Simple graphical layout tool; does not require complex text
entry
• Import .dxf building outlines
• Selectable 3D isometric or 2D plan views.
• Automatically generated bill of materials.
• Direct NIST Fire Dynamics Simulator (FDS) integration
allows system
y response
p time to be modeled

2
REMOTE SYSTEM CONFIGURATION
• Free
F software
ft
• Tool for configuring and troubleshooting
• View, save and print historical event logs and statistical
information

3
SenseNET™
• C
Centrally
t ll manage and d globally
l b ll configure
fi up tto 16 loop
l with
ith
as many as 127 detectors per loop
• Import AutoCAD, JPG, BMP, etc
• View real-time detector status
• SiteMail™ and SitePage™ for automatic email/text alarm
alerts
• SiteAudit™ logs all events in real time
p
• SiteScan™ detects all attached devices for rapid
configuration
• Send email and page alerts of alarm and fault conditions
• User
Use definable sound
so nd files for
fo alarm
ala m and fault
fa lt conditions
onditions
• Displays maps with specific instructions
• 4 levels of password protected access
• Full system diagnostics
4
SenseNET™

5
REMOTE Software
Configuration
DEFAULT ACCESS CODE

Default code is “0102”


0102

7
DAY-NIGHT MODE: Manual Switch
• M
Moded can beb switched
it h d manually
ll when
h someone leaves
l the
th
office, activates a security point, etc

8
FLOW MONITORING
• Individual
I di id l portt sensors can b
be enabled
bl d or disabled
di bl d
•‘Actual’ flow displayed
•Should be ~60 ± 10;
•If < 30 or > 80 then pipe
layout requires attention

•Low & High limits set


automatically during setup

•Fan speed alterable


•Decrease to reduce noise
•Increase to reduce
transport times
•Altering speed affects
current consumption

9
BATTERY & MAINS CHECK
• Di
Disable
bl if power monitoring
it i nott used
d to
t preventt trouble
t bl
signals

10
FRONT-PANEL ENABLE / DISABLE
• R
Reset,
t Test
T t & Isolate
I l t b buttons
tt can b
be enabled
bl d or disabled
di bl d
depending on the environment
• Reset is disabled by default: should be enabled to latch
alarms or faults

11
Referencing
• Used
U d when
h “Referencing”
“R f i ” a detectors
d t t obscuration
b ti level
l l

12
Miscellaneous
• Miscellaneous
Mi ll settings
tti

13
LATCHING / NON-LATCHING
• S
Specified
ifi d ALARM and
d FAULT conditions
diti latch
l t h until
til resett att
the front panel

14
SET ALARM FACTOR
• Sensitivity
S iti it setting
tti ffor th
the d
detector
t t

0 – Most Sensitive
8 – Least Sensitive

15
ALARM FACTOR: Selected based on Area
• At ‘0’
‘0’, b
background
k d llevell iis closely
l l ttracked
k d
– incorrect selection may lead to nuisance alarms
• At ‘8’,
8 , background level is tracked at greater distance
– nuisance alarms extremely rare; however detector will
be operating at lower sensitivity

16
SET DATE & TIME
• To
T ensure correctt date
d t and
d time
ti stamp
t on events
t

17

You might also like