CAT.

EUS40-46 A -UK

Regulator with Built-in Pressure Gauge


Filter Regulator with Built-in Pressure Gauge
Series ACG /ARG /AWG

Visibility of pressure gauge is improved


in various installation places

Equipment When mounting


on equipment
near foot level
OUT

Floor

When mounting
on a panel
SMC

Panel
Installation and removal of pressure gauge Mounting angle of pressure gauge is selectable
cover is possible with one-touch. (PAT.PEND.) depending on the piping direction
∗ Mounting angle can be changed as desired. For details, refer to “Procedure for
Easy to adjust limit indicator. replacing or changing the mounting angle of a pressure gauge” on back page 6.

Mounting angle 0° 90°

Mounting IN OUT IN OUT

MPa
angle view
MPa
P P
US K US K
H to L O C H to L O C

Mounting angle 180° 270°


MPa
Mounting IN OUT IN OUT

MPa
angle view
P P
US K US K
H to L O C H to L O C

∗ Pressure gauge will not revolve even


Pressure gauge anti-revolving mechanism (PAT.PEND.) after the handle is operated.

Space saving, Labour


Labo r saving
Panel-cut for pressure gauge is not necessary.
In the case of panel mounting, the number of holes required for installing the products
(pressure gauge plus regulator handle parts) can be reduced into one location. By
changing the angle of pressure gauge, the internal volume of a panel can be used effectively.
 Mounting example: In the case of aligning three ARG30s in line.

Mounting at 90° (In the case of restricted in side direction) Mounting at 45° (In the case of considering the effectiveness of panel)
∗ Contact SMC separately, since it will be made to order.
Surface of panel
OUT Surface of panel
SMC

MPa MPa MPa MPa MPa MPa


P K P K P K P K P K P K
U C U C U C U C U C U C
SH SH SH SH SH SH
to L O to L O to L O to L O to L O to L O

IN
58

Bottom of panel
Bottom of panel
45°

IN 1 IN 1 IN 1 SM SM SM
C IN C IN C IN
1 1 1
SMC

SMC

SMC

2 2 2
O O O
U U U
2 OUT 2 OUT 2 OUT T T T

In the case of ARG30, dimension in height


can be reduced by approx. 30 mm.

Features 1
Standard Combinations

Components
Combination Model Port size Regulator with Built-in Filter Regulator with
Air filter Pressure Gauge Built-in Pressure Gauge Lubricator Mist separator
AF ARG AWG AL AFM

AF + ARG + AL
ACG20 1/8, 1/4 AF20 ARG20 AL20

ACG30 1/4, 3/8 AF30 ARG30 AL30

ACG40 1/4, 3/8, 1/2 AF40 ARG40 AL40

AWG + AL
ACG20A 1/8, 1/4 AWG20 AL20

ACG30A 1/4, 3/8 AWG30 AL30

ACG40A 1/4, 3/8, 1/2 AWG40 AL40

AF + ARG
ACG20B 1/8, 1/4 AF20 ARG20

ACG30B 1/4, 3/8 AF30 ARG30

ACG40B 1/4, 3/8, 1/2 AF40 ARG40

AF + AFM + ARG
ACG20C 1/8, 1/4 AF20 ARG20 AFM20

ACG30C 1/4, 3/8 AF30 ARG30 AFM30

ACG40C 1/4, 3/8, 1/2 AF40 ARG40 AFM40

AWG + AFM
ACG20D 1/8, 1/4 AWG20 AFM20

ACG30D 1/4, 3/8 AWG30 AFM30

ACG40D 1/4, 3/8, 1/2 AWG40 AFM40

INDEX
 Air Combination  Regulator with Built-in Pressure Gauge
Air Filter + Regulator with Built-in Pressure Gauge + Lubricator Regulator with Built-in Pressure Gauge
ACG20/30/40 P.4 ARG20/30/40 P.20
Filter Regulator with Built-in Pressure Gauge + Lubricator Regulator with Built-in Pressure Gauge with Back Flow Mechanism
ACG20A/30A/40A P.7 ARG20K/30K/40K P.24
Air Filter + Regulator with Built-in Pressure Gauge
ACG20B/30B/40B P.9  Filter Regulator with Built-in Pressure Gauge
Air Filter + Mist Separator + Regulator with Built-in Pressure Gauge Filter Regulator with Built-in Pressure Gauge
ACG20C/30C/40C P.11 AWG20/30/40 P.31
Filter Regulator with Built-in Pressure Gauge + Mist Separator Filter Regulator with Built-in Pressure Gauge with Back Flow Mechanism
ACG20D/30D/40D P.13 AWG20K/30K/40K P.35

1
Series ACG

How to Order

ACG 30 A 03 G1
Option
Symbol Description Applicable model
Body size - — —
Symbol Port size 1 (8) 0.02 to 0.2 MPa setting ACG20 to 40
20 1/8 2 Metal bowl ACG20 to 40
30 3/8 3 Lubricator with drain cock ACG20 to 40
40 1/2 6 Nylon bowl ACG20 to 40
8 Metal bowl with level gauge ACG30, 40
C With bowl guard ACG20
Model combination
Combination J (9) Filter case with drain guide ACG20 to 40

Regulator Filter N Non-relieving type ACG20 to 40


Symbol Air with Regulator Mist R Flow direction: Right  Left ACG20 to 40
Lubricator with Built-in
filter Built-in separator Drain cock with barb fitting:
ACG30, 40
Pressure Pressure W ø6 x ø4 nylon tubing
Gauge Gauge
Y Regulator with upward facing handle ACG20 to 40
- (1) (2) (3) — — Name plate and pressure gauge in
(10)
A — — (2) (1) — Z imperial units (PSI), caution plate ACG20 to 40
(1) for bowl (PSI • °F)
B (1) (2) — — —
∗ When more than one specification is required, indicate in
C (1) (3) — — (2) ascending alphanumeric order.
Note 8) Adjusting spring and pressure gauge (full-span 0.3
D — — — (1) (2)
MPa) are different from those for the standard
Note 1) Wall mount is not available for size 20 specification. Outlet pressure may still be increased
regulator with downward facing handle in B from 0.2 MPa or more.
combination. Contact SMC when wall mount Note 9) Without a valve function.
is needed. Note 10) For thread type NPT.
Note 2) The number inside ( ) indicates the This product is for overseas use only according to the
combination order counted from the inlet new Measurement Law. (The SI unit type is provided
side. for use in Japan.)

Attachment
Thread type Attachment Applicable Port size for
Symbol Description mounting intermediate
Symbol Type position model air release

- Rc -

N NPT AF + ARG + [K] + AL ACG20: 1/8


ACG20 to 40
Check
K valve ACG30: 1/4
F G AW + [K] + AL ACG20A to 40A ACG40: 3/8
Note 3) Drain guide is NPT1/8 for ACG20 and NPT1/4 for
AF + ARG + [S] + AL ACG20 to 40
ACG30 and 40. Auto-drain port is provided with (7) Pressure
ø3.8" One-touch fitting (applicable to ACG30 and S switch
AF + [S] + ARG ACG20B to 40B
40).
AF + AFM + [S] + ARG ACG20C to 40C
Note 4) Drain guide is G1/8 for ACG20 and G1/4 for
ACG30 and 40. AF + ARG + AL + [V] ACG20 to 40
Residual
AW + AL + [V] ACG20A to 40A
pressure
Port size V relief AF + ARG + [V] ACG20B to 40B
Port Body size 3 port AF + AFM + ARG + [V] ACG20C to 40C
Symbol size valve
20 30 40 AW + AFM + [V] ACG20D to 40D
01 1/8  — — Note 6) When more than one attachment is required, order in
02 1/4    alphabetical order.
Note 7) Pressure switch cannot be mounted on the inlet and outlet
03 3/8 —   sides of an ARG with an upward facing handle (optional
04 1/2 — —  specification: -Y).

Mounting Angle of Pressure Gauge


Accessory
Symbol G1
Symbol Description Applicable model
Mounting angle 0°
- — —
C Float type auto-drain (Normally closed) ACG20 to 40
D Float type auto-drain (Normally open) ACG30, 40 Mounting angle IN OUT
When more than one specification is required, indicate in ascending alphabetical view
order. PU
MPa
SH L OCK
to

Mounting angle of pressure gauge 0°


Note 5) Mounting angle of pressure gauge is G1 only.
If other mounting angles are needed, contact SMC. Mounting angle
view OUT IN
∗ Possible to change to the optional mounting angles.
For details, refer to back page 6, “Procedure for replacing or (-R specification) MPa
PU
changing the mounting angle of a pressure gauge”. SH L OCK
to

2
Air Combination Series ACG

Accessory/Optional Combinations

: Combination available : Combination not available : Varies depending on a model : Available only with NPT thread
F.R.L. unit applicable model

Symbol
Combination
Accessory Option
Accessory/ ACG30 ACG30A ACG30B ACG30C ACG30D
ACG20 ACG20A ACG20B ACG20C ACG20D to to to to to
Optional specifications C D 1 2 3 6 8 C J N RW Y Z ACG40 ACG40A ACG40B ACG40C ACG40D

Float type auto-drain (N.C.) C


Float type auto-drain (N.O.) D

0.02 to 0.2 MPa setting -1


Metal bowl -2
Lubricator with drain cock -3
Nylon bowl -6
Metal bowl with level gauge -8

With bowl guard -C


Drain guide -J
Non-relieving type -N
Flow direction: Right  Left -R

Drain cock with barb fitting -W


Regulator upward facing handle -Y
Name plate, caution plate for bowl, and
pressure gauge in imperial units (PSI, °F) -Z

Attachments

Port size Function

Check valve 1/8, 1/4, 3/8 Prevents back flow from lubricator. P. 15

Pressure switch Compact switch P. 16

Residual pressure relief


3 port valve 1/8, 1/4, 3/8, 1/2 Releases residual pressure in lines. P. 17

Accessories
Refer to page 18 for spacers and brackets.

3
Air Combination
Air Filter + Regulator + Lubricator

Series ACG20/30/40
JIS Symbol

ACG20 ACG40 Air filter Regulator Lubricator


Standard Specifications
Model ACG20 ACG30 ACG40
Air filter AF20 AF30 AF40
Component Regulator ARG20 ARG30 ARG40
Lubricator AL20 AL30 AL40
1/8 1/4 1/4
Port size 3/8
1/4 3/8 1/2
Fluid Air
Proof pressure 1.5 MPa
Maximum operating pressure 1.0 MPa
Regulating pressure range 0.05 to 0.85 MPa
Relief pressure Set pressure + 0.05 MPa (at relief flow rate of 0.1 l/min (ANR))
Ambient and fluid temperature –5 to 60°C (With no freezing)
Nominal filtration rating 5 µm
Recommended lubricant Class 1 turbine oil (ISO VG32)
Regulator construction Relieving type
Bowl material Polycarbonate
Bowl guard Optional Standard
Sight dome material Polycarbonate
Weight (kg) 0.78 1.11 1.87

Accessory/Attachment Part No.


Accessory/Attachment part no.
Description Model ACG20 ACG30 ACG40
(1) Standard 0 to 1.0 MPa GB2-10AS GB3-10AS GB4-10AS
Pressure gauge
Optional 0 to 0.3 MPa GB2-3AS GB3-3AS GB4-3AS
Acces-

Normally closed AD27 AD37 AD47


sory

(2)
Float type auto-drain
Normally open — AD38 AD48
Spacer Y200 Y300 Y400
Attachment

Spacer with bracket Y200T Y300T Y400T


(3)
Check valve (4) AKM2000-01, (02) AKM3000-(01), 02 AKM4000-(02), 03
(4)
Pressure switch (5) IS1000M-20 IS1000M-30 IS1000M-40
Residual pressure relief 3 port valve (4) VHS20-01, 02 VHS30-02, 03 VHS40-02, 03, 04
Note 1) Contact SMC regarding the connection thread NPT and pressure gauge supply for PSI unit specifications.
Note 2) Minimum operating pressure: N.O. type–0.1 MPa; N.C. type–0.15 MPa. Contact SMC regarding the specifications for PSI unit and °F.
Note 3) For F.R.L. units, port sizes not in ( ) are for standard application.
Note 4) Separate spacers are required for modular unit.
Note 5) Pressure switch cannot be mounted on the inlet and outlet sides of an ARG with an upward facing handle (optional specification: -Y).

4
Air Combination Series ACG20/30/40

Flow Characteristics Condition: Inlet pressure 0.7 MPa

ACG20 Rc1/4 ACG30 Rc3/8 ACG40 Rc1/2


0.6 0.6 0.6
Outlet pressure (MPa)

Outlet pressure (MPa)

Outlet pressure (MPa)


0.5 0.5 0.5

0.4 0.4 0.4

0.3 0.3 0.3

0.2 0.2 0.2

0.1 0.1 0.1

0 0 0
0 200 400 600 800 0 500 1000 1500 0 1000 2000 3000
Flow rate (l/min (ANR)) Flow rate (l/min (ANR)) Flow rate (l/min (ANR))

Pressure Characteristics Conditions: Inlet pressure 0.7 MPa, Outlet pressure 0.2 MPa, Flow rate 20 l/min (ANR)

ACG20 Rc1/4 ACG30 Rc3/8 ACG40 Rc1/2


0.25 0.25 0.25

Set point Set point Set point


Outlet pressure (MPa)

Outlet pressure (MPa)

Outlet pressure (MPa)


0.2 0.2 0.2

0.15 0.15 0.15

0 0 0
0 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 0 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 0 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0
Inlet pressure (MPa) Inlet pressure (MPa) Inlet pressure (MPa)

Specific Product Precautions


Piping Selection
Warning Caution
1. When mounting a check valve, make sure the arrow (IN side) 1. Mounting a 3 port valve for residual pressure release on the IN
points in the correct direction of air flow. side of the lubricator can cause lubricant to back flow. Take
measures to prevent lubricant from splashing by installing a
filter on the EXH port.
Selection 2. An F.R.L. unit shipped from the plant has its model number
Warning labeled. However, components that are combined together
during the distribution process do not have a label on them.
1. Float type auto-drain 3. Contact SMC when mounting a pressure switch, filter regulator
Operate under the following conditions to avoid malfunction. on the OUT side of the 3 port valve for residual pressure
<N.O. type> release.
• Operating compressor: 0.75 kW (100 l/min (ANR)) or more.
When using 2 or more auto-drains, multiply the value above Air Supply
by the number of auto-drains to find the capacity of the
compressors you will need. Caution
For example, when using 2 auto-drains, 1.5 kW (200 l/min
(ANR)) of the compressor capacity is required. 1. Use an air filter with 5 µm or less filtration rating on the inlet
side of the valve to avoid any damage to the seat caused by
• Operating pressure: 0.1 MPa or more. dust when mounting a 3 port valve for residual pressure
<N.C. type> release on the inlet side.
• Operating pressure for AD17/27: 0.1 MPa or more.
• Operating pressure for AD37/47: 0.15 MPa or more.
2. Use a regulator or filter regulator with a back flow mechanism
when mounting a 3 port valve for residual pressure release on
the IN side to ensure the release of the residual pressure.
Otherwise, residual pressure will not be fully released.

5
Series ACG20/30/40

Dimensions
ACG20 Standard ACG30/40 Standard
Downward facing handle Downward facing handle
A
P G
A E F L
2-ø
P G E F

L
ø
2-

C
H1
IN OUT
C
H2 H1

SMC

IN OUT

2-L
H2
SMC

OUT
4-L
J

M 2-K

B
B

M 4-K Port size


Port size
for maintenance

N Drain
Min. clearance

for maintenance
Min. clearance
Drain
D

Air filter Regulator Lubricator

D
Air filter Regulator Lubricator

ACG20 Optional (-Y) ACG30/40 Optional (-Y)


Upward facing handle Upward facing handle
A
P G E F
A
P G E F

C L
2-ø
L
C

ø
2-

H1
H1

IN SMC
OUT IN SMC
OUT
H2

4-L

2-L
H2
J

OUT
OUT
B

M 4-K M 2-K
B

Port size
Port size
O
S
for maintenance

Drain
Min. clearance
D

Air filter Regulator Lubricator


maintenance

Drain
clearance
Min.
D

for

Air filter Regulator Lubricator

Applicable model ACG20 ACG30/40


Accessory/Optional
specifications With auto-drain (N.C.) Metal bowl With drain guide With auto-drain (N.O./N.C.) Metal bowl Metal bowl with level gauge With drain guide Drain cock with barb fitting
B

B
B

B
B

Dimensions
B

N.O.: Black
B

N.C.: Gray
1/8
ø10 One-touch 1/4 Barb fitting
M5 Width across flats 17 fitting Width across flats 17 Applicable tubing: T0604

Standard specifications
Model Port size Bracket mount
A B C D P
E F G H1 H2 J K L øL M
ACG20 1/8, 1/4 126 87 36 60 28.5 41.5 43 30 24 — (1) — (1) — (1) — (1) 5.5 3.2
ACG30 1/4, 3/8 167 115 41 80 30 55 57 41 35 35 — 14 7 7 4
ACG40 1/4, 3/8, 1/2 220 147 48 110 38 72.5 75 50 40 40 — 18 9 9 4

Accessory/Optional specifications
Model Upward facing handle (2) With auto-drain (3) With barb fitting (3) With drain guide (3) Metal bowl (3) Metal bowl with level gauge (3)
C H2 J K L B B B B B
ACG20 87 24 33 12 5.5 105 — 91 87 —
ACG30 108.5 35 — 14 7 156 123 122 128 148
ACG40 114.5 40 — 18 9 186 155 154 160 180
Note 1) In the case of the ACG20’s standard specification (downward facing handle), the wall mounting is not possible using the lower side mounting hole on the spacer with a
bracket. Use the upper side mounting hole when wall mounting.
Note 2) In the case of the upward facing handle in the optional specification, the C dimension will change. Also, in the case of the ACG20, wall mounting is possible by using the
lower side mounting hole on the spacer with a bracket.
Note 3) For the accessory/optional specifications (with auto-drain, with barb fitting, with drain guide, metal bowl, or metal bowl with level gauge), the total length (B dimension) will vary.
6
Air Combination

Filter Regulator + Lubricator

Series ACG20A/30A/40A
JIS Symbol

ACG20A ACG40A Filter regulator Lubricator


Standard Specifications
Model ACG20A ACG30A ACG40A
Filter regulator AWG20 AWG30 AWG40
Component
Lubricator AL20 AL30 AL40
1/8 1/4 1/4
Port size 3/8
1/4 3/8 1/2
Fluid Air
Proof pressure 1.5 MPa
Maximum operating pressure 1.0 MPa
Regulating pressure range 0.05 to 0.85 MPa
Relief pressure Set pressure + 0.05 MPa (at relief flow rate of 0.1 l/min (ANR))
Ambient and fluid temperature –5 to 60°C (With no freezing)
Nominal filtration rating 5 µm
Recommended lubricant Class 1 turbine oil (ISO VG32)
Filter regulator construction Relieving type
Bowl material Polycarbonate
Bowl guard Optional Standard
Sight dome material Polycarbonate
Weight (kg) 0.65 0.86 1.55

Accessory/Attachment Part No.


Accessory/Attachment part no.
Description Model ACG20A ACG30A ACG40A
(1) Standard 0 to 1.0 MPa GB2-10AS GB3-10AS GB4-10AS
Pressure gauge
Optional 0 to 0.3 MPa GB2-3AS GB3-3AS GB4-3AS
Acces-

Normally closed AD27 AD37 AD47


sory

(2)
Float type auto-drain
Normally open — AD38 AD48
Spacer
Attachment

Y200 Y300 Y400


Spacer with bracket Y200T Y300T Y400T
Check valve (3)
(4) AKM2000-01, (02) AKM3000-(01), 02 AKM4000-(02), 03
Residual pressure relief 3 port valve (4) VHS20-01, 02 VHS30-02, 03 VHS40-02, 03, 04
Note 1) Contact SMC regarding the connection thread NPT and pressure gauge supply for PSI unit specifications.
Note 2) Minimum operating pressure: N.O. type–0.1 MPa; N.C. type–0.15 MPa. Contact SMC regarding the PSI and °F unit specifications.
Note 3) For F.R.L. units, port sizes not in ( ) are for standard application.
Note 4) Separate spacers are required for modular unit.

7
Series ACG20A/30A/40A

Dimensions
ACG20A N A
P G E

øL
H2 H1
IN SMC OUT

2-L
J
OUT

B
M 2-K
Port size

S O O S

for maintenance
Min. clearance
Drain

D
Filter regulator Lubricator

ACG30A/40A N A
P G E
C

øL
H1

IN SMC OUT
H2

OUT

M
B

K
Port size
for maintenance
Min. clearance

Drain
D

Filter regulator Lubricator

Applicable model ACG20A ACG30A/40A


Accessory/Optional
specifications With auto-drain (N.C.) Metal bowl With drain guide With auto-drain (N.O./N.C.) Metal bowl Metal bowl with level gauge With drain guide Drain cock with barb fitting
B

B
B

B
B

Dimensions
B

N.O.: Black
B

N.C.: Gray
1/8
ø10 One-touch 1/4 Barb fitting
M5 Width across flats 17 fitting Width across flats 17 Applicable tubing: T0604

Standard specifications
Model Port size Bracket mount
A B C D N P
E G H1 H2 J K L øL M
ACG20A 1/8, 1/4 83 87 91 60 2.5 26 41.5 30 24 24 33 12 5.5 5.5 3.2
ACG30A 1/4, 3/8 110 115 108.5 80 2.5 30 55 41 35 35 — 14 7 7 4
ACG40A 1/4, 3/8, 1/2 145 147 114.5 110 0 38 72.5 50 40 40 — 18 9 9 4
Note)
Accessory/Optional specifications
Model With auto-drain With barb fitting With drain guide Metal bowl Metal bowl with level gauge
B B B B B
ACG20A 105 — 91 87 —
ACG30A 156 123 122 128 148
ACG40A 186 155 154 160 180
Note) For the accessory/optional specifications (with auto-drain, with barb fitting, with drain guide, metal bowl, or with level gauge), the total length (B dimension) will vary.

8
Air Combination
Air Filter + Regulator

Series ACG20B/30B/40B
JIS Symbol

ACG20B ACG40B Air filter Regulator


Standard Specifications
Model ACG20B ACG30B ACG40B
Air filter AF20 AF30 AF40
Component
Regulator ARG20 ARG30 ARG40
1/8 1/4 1/4
Port size 3/8
1/4 3/8 1/2
Fluid Air
Proof pressure 1.5 MPa
Maximum operating pressure 1.0 MPa
Regulating pressure range 0.05 to 0.85 MPa
Relief pressure Set pressure + 0.05 MPa (at relief flow rate of 0.1 l/min (ANR))
Ambient and fluid temperature –5 to 60°C (With no freezing)
Nominal filtration rating 5 µm
Regulator construction Relieving type
Bowl material Polycarbonate
Bowl guard Optional Standard
Weight (kg) 0.56 0.74 1.25

Accessory/Attachment Part No.


Accessory/Attachment part no.
Description Model ACG20B ACG30B ACG40B
(1) Standard 0 to 1.0 MPa GB2-10AS GB3-10AS GB4-10AS
Pressure gauge
Optional 0 to 0.3 MPa GB2-3AS GB3-3AS GB4-3AS
Acces-

Normally closed AD27 AD37 AD47


sory

(2)
Float type auto-drain
Normally open — AD38 AD48
Attachment

Spacer Y200 Y300 Y400


Spacer with bracket Y200T Y300T Y400T
(3)
Pressure switch (4) IS1000M-20 IS1000M-30 IS1000M-40
Residual pressure relief 3 port valve (3) VHS20-01, 02 VHS30-02, 03 VHS40-02, 03, 04
Note 1) Contact SMC regarding pressure gauge supply for PSI unit specifications.
Note 2) Minimum operating pressure: N.O. type–0.1 MPa; N.C. type–0.15 MPa. Contact SMC regarding the PSI and °F unit specifications.
Note 3) Separate spacers are required for modular unit.
Note 4) Pressure switch cannot be mounted on the inlet and outlet sides of an ARG with an upward facing handle (optional specification: -Y).

9
Series ACG20B/30B/40B

Dimensions
ACG20B Standard ACG30B/40B Standard
Downward facing handle Downward facing handle
A N
A N P G E
P G E øL
øL

C
H1
C
H2 H1

IN SMC
OUT IN OUT
SMC

H2
2-L
J

L
B

M 2-K M

B
Port size K
Port size
o s
for maintenance

Drain
Min. clearance
D

Air filter Regulator

for maintenance
Drain

Min. clearance
D
Air filter Regulator

ACG20B Optional (-Y) ACG30B/40B Optional (-Y)


Upward facing handle Upward facing handle
A N
P G E
A N
P G E

øL

C
øL
C

H1
H2 H1

IN SMC
OUT IN SMC
OUT
2-L

H2
J

L
B

M 2-K M
B

Port size K
Port size
O
S o s
for maintenance

Drain
Min. clearance
D

Air filter Regulator


maintenance

Drain
clearance
Min.
for
D

Air filter Regulator

Applicable model ACG20B ACG30B/40B


Accessory/Optional
specifications With auto-drain (N.C.) Metal bowl With drain guide With auto-drain (N.O./N.C.) Metal bowl Metal bowl with level gauge With drain guide Drain cock with barb fitting
B

B
B
B

Dimensions
B

N.O.: Black
B

N.C.: Gray
1/8
ø10 One-touch 1/4 Barb fitting
M5 Width across flats 17 fitting Width across flats 17 Applicable tubing: T0604

Standard specifications
Model Port size Bracket mount
A B C D N P
E G H1 H2 J K L øL M
ACG20B 1/8, 1/4 83 87 29 60 2.5 28.5 41.5 30 — (1) — (1) — (1) — (1) — (1) — (1) 3.2
ACG30B 1/4, 3/8 110 115 41 80 2.5 29.5 55 41 35 35 — 14 7 7 4
ACG40B 1/4, 3/8, 1/2 145 147 48 110 0 38 72.5 50 40 40 — 18 9 9 4

Accessory/Optional specifications
Metal bowl with (3)
Model Upward facing handle (2) With auto-drain (3) With barb fitting (3) With drain guide (3) Metal bowl (3) level gauge
C H1 H2 J K L øL B B B B B
ACG20B 87 24 24 33 12 5.5 5.5 105 — 91 87 —
ACG30B 108.5 35 35 — 14 7 7 156 123 122 128 148
ACG40B 114.5 40 40 — 18 9 9 186 155 154 160 180
Note 1) In the case of the ACG20B’s standard specification (downward facing handle), the wall mounting is not possible using the lower side mounting hole on the spacer with a
bracket. Contact SMC.
Note 2) In the case of the upward facing handle in the optional specification, the C dimension will change. Also, in the case of the ACG20B, wall mounting is possible by using
the lower side mounting hole on the spacer with a bracket.
Note 3) For the accessory/optional specifications (with auto-drain, with barb fitting, with drain guide, metal bowl, or metal bowl with level gauge), the total length (B dimension) will vary.
10
Air Combination
Air Filter + Mist Separator + Regulator

Series ACG20C/30C/40C
JIS Symbol

ACG20C ACG40C Air filter Mist Separator Regulator


Standard Specifications
Model ACG20C ACG30C ACG40C
Air filter AF20 AF30 AF40
Component Mist separator AFM20 AFM30 AFM40
Regulator ARG20 ARG30 ARG40
1/8 1/4 1/4
Port size 3/8
1/4 3/8 1/2
Fluid Air
Proof pressure 1.5 MPa
Maximum operating pressure 1.0 MPa
Regulating pressure range 0.05 to 0.85 MPa
Rated flow (l/min (ANR) (1) 200 450 1100
Relief pressure Set pressure + 0.05 MPa (at relief flow rate of 0.1 l/min (ANR))
Ambient and fluid temperature –5 to 60°C (With no freezing)
Nominal filtration rating AF: 5 µm; AFM: 0.3 µm (95% filtered particle size)
(2)
Outlet side oil mist concentration Maximum 1.0 mg/Nm3 (approx. 0.8 ppm)
Regulator construction Relieving type
Bowl material Polycarbonate
Bowl guard Optional Standard
Weight (kg) 0.79 1.06 1.89
Note 1) P1 = 0.7 MPa, 0.5 MPa setting and fully open
Note 2) At compressor discharge 30 mgf/Nm3.

Accessory/Attachment Part No.


Accessory/Attachment part no.
Description Model ACG20C ACG30C ACG40C
Standard 0 to 1.0 MPa
(1) GB2-10AS GB3-10AS GB4-10AS
Pressure gauge
Optional 0 to 0.3 MPa GB2-3AS GB3-3AS GB4-3AS
Acces-

Normally closed AD27 AD37 AD47


sory

(2)
Float type auto-drain
Normally open — AD38 AD48
Attachment

Spacer Y200 Y300 Y400


Spacer with bracket Y200T Y300T Y400T
(3)
Pressure switch (4) IS1000M-20 IS1000M-30 IS1000M-40
Residual pressure relief 3 port valve (3) VHS20-01, 02 VHS30-02, 03 VHS40-02, 03, 04
Note 1) Contact SMC regarding pressure gauge supply for PSI unit specifications.
Note 2) Minimum operating pressure: N.O. type–0.1 MPa; N.C. type–0.15 MPa. Contact SMC regarding the PSI and °F unit specifications.
Note 3) Separate spacers are required for modular unit.
Note 4) Pressure switch cannot be mounted on the inlet and outlet sides of an ARG with an upward facing handle (optional specification: -Y).

11
Series ACG20C/30C/40C

Dimensions

ACG20C Standard ACG30C/40C Standard


Downward facing handle Downward facing handle
A N
P G E F øL
A N 2-
P G E F øL
2-

C
H1
IN OUT
C
H2 H1

SMC

IN OUT

2-L
H2
SMC
4-L
J

M 2-K

B
B

M 4-K
Port size
Port size

o s o s
for maintenance

Drain Drain
Min. clearance

for maintenance
D

Drain Drain

Min. clearance
Air filter Mist separator Regulator

D
Air filter Mist separator Regulator

ACG20C Optional (-Y) ACG30C/40C Optional (-Y)


Upward facing handle Upward facing handle
A N
P G E F
A N
P G E F

2-
øL

C
2-ø
C

L
H1
H2 H1

IN SMC
OUT IN SMC
OUT
4-L

2-L
H2
J
B

M 4-K M 2-K
B

Port size
Port size
O
S o s o s
for maintenance

Drain Drain
Min. clearance

Air filter Mist separator Regulator


maintenance
D

Drain Drain
clearance
Min.
for
D

Air filter Mist separator Regulator

Applicable model ACG20C ACG30C/40C


Accessory/Optional
specifications With auto-drain (N.C.) Metal bowl With drain guide With auto-drain (N.O./N.C.) Metal bowl Metal bowl with level gauge With drain guide Drain cock with barb fitting
B

B
B

B
B
B

Dimensions N.O.: Black


B

N.C.: Gray
1/8
M5 ø10 One-touch 1/4 Barb fitting
Width across flats 17 fitting Width across flats 17 Applicable tubing: T0604

Standard specifications
Model Port size Bracket mount
A B C D N P
E F G H1 H2 J K L øL M
ACG20C 1/8, 1/4 126 87 29 60 2.5 28.5 41.5 43 30 24 — (1) — (1) — (1)
— (1) 5.5 3.2
ACG30C 1/4, 3/8 167 115 41 80 2.5 30 55 57 41 35 35 — 14 7 7 4
ACG40C 1/4, 3/8, 1/2 220 147 48 110 0 38 72.5 75 50 40 40 — 18 9 9 4
Accessory/Optional specifications
Model Upward facing handle (2) With auto-drain (3) With barb fitting (3) With drain guide (3) Metal bowl (3) Metal bowl with level gauge (3)
C H2 J K L B B B B B
ACG20C 87 24 33 12 5.5 105 — 91 87 —
ACG30C 108.5 35 — 14 7 156 123 122 128 148
ACG40C 114.5 40 — 18 9 186 155 154 160 180
Note 1) In the case of the ACG20C’s standard specification (downward facing handle), the wall mounting is not possible using the lower side mounting hole on the spacer with a
bracket. Use the upper side mounting hole when wall mounting.
Note 2) In the case of the upward facing handle in the optional specification, the C dimension will change. Also, in the case of the ACG20C, wall mounting is possible by using
the lower side mounting hole on the spacer with a bracket.
Note 3) For the accessory/optional specifications (with auto-drain, with barb fitting, with drain guide, metal bowl, or metal bowl with level gauge), the total length (B dimension) will vary.
12
Air Combination

Filter Regulator + Mist Separator

Series ACG20D/30D/40D
JIS Symbol

ACG20D ACG40D Filter regulator Mist Separator


Standard Specifications
Model ACG20D ACG30D ACG40D
Filter regulator AWG20 AWG30 AWG40
Component
Mist separator AFM20 AFM30 AFM40
1/8 1/4 1/4
Port size 3/8
1/4 3/8 1/2
Fluid Air
Proof pressure 1.5 MPa
Maximum operating pressure 1.0 MPa
Regulating pressure range 0.05 to 0.85 MPa
Rated flow (l/min (ANR) (1) 150 330 800
Relief pressure Set pressure + 0.05 MPa (at relief flow rate of 0.1 l/min (ANR))
Ambient and fluid temperature –5 to 60°C (With no freezing)
Nominal filtration rating AF: 5 µm; AFM: 0.3 µm (95% filtered particle size)
(2)
Outlet side oil mist concentration Maximum 1.0 mg/Nm3 (approx. 0.8 ppm)
Regulator construction Relieving type
Bowl material Polycarbonate
Bowl guard Optional Standard
Weight (kg) 0.63 0.85 1.52
Note 1) P1 = 0.7 MPa, 0.5 MPa setting and fully open
Note 2) At compressor discharge 30 mgf/Nm3.

Accessory/Attachment Part No.


Accessory/Attachment part no.
Description Model ACG20D ACG30D ACG40D
Standard 0 to 1.0 MPa
(1) GB2-10AS GB3-10AS GB4-10AS
Pressure gauge
Optional 0 to 0.3 MPa GB2-3AS GB3-3AS GB4-3AS
Acces-

Normally closed AD27 AD37 AD47


sory

(2)
Float type auto-drain
Normally open — AD38 AD48
Attachment

Spacer Y200 Y300 Y400


Spacer with bracket Y200T Y300T Y400T
Residual pressure relief 3 port valve (3) VHS20-01, 02 VHS30-02, 03 VHS40-02, 03, 04
Note 1) Contact SMC regarding pressure gauge supply for PSI unit specifications.
Note 2) Minimum operating pressure: N.O. type–0.1 MPa; N.C. type–0.15 MPa. Contact SMC regarding the PSI and °F unit specifications.
Note 3) Separate spacers are required for modular unit.

13
Series ACG20D/30D/40D

Dimensions
ACG20D P G
N
E
A

øL

C
H2 H1
IN SMC OUT

2-L
J
OUT

B
M
2-K
Port size
O
S O S O S

for maintenance
Min. clearance
Drain Drain

D
Filter regulator Mist separator

ACG30D/40D N A
P G C E

øL
H1

IN SMC OUT
H2

OUT

M
B

K
Port size
for maintenance

Drain Drain
Min. clearance
D

Filter regulator Mist separator

Applicable model ACG20D ACG30D/40D


Accessory/Optional
specifications With auto-drain (N.C.) Metal bowl With rain guide With auto-drain (N.O./N.C.) Metal bowl Metal bowl with level gauge With drain guide Drain cock with barb fitting
B

B
B

B
B
B

Dimensions
B

N.O.: Black
B

N.C.: Gray
1/8
ø10 One-touch 1/4 Barb fitting
M5 Width across flats 17 fitting Applicable tubing: T0604
Width across flats 17

Standard specifications
Model Port size Bracket mount
A B C D N P
E G H1 H2 J K L øL M
ACG20D 1/8, 1/4 83 87 91 60 2.5 26 41.5 30 24 24 33 12 5.5 5.5 3.2
ACG30D 1/4, 3/8 110 115 108.5 80 2.5 30 55 41 35 35 — 14 7 7 4
ACG40D 1/4, 3/8, 1/2 145 147 114.5 110 0 38 72.5 50 40 40 — 18 9 9 4

Accessory/Optional specifications Note)

Model With auto-drain With barb fitting With drain guide Metal bowl Metal bowl with level gauge
B B B B B
ACG20D 105 — 91 87 —
ACG30D 156 123 122 128 148
ACG40D 186 155 154 160 180
Note) For the accessory/optional specifications (with auto-drain, with barb fitting, with drain guide, metal bowl, or metal bowl with level
gauge), the total length (B dimension) will vary.

14
Series ACG
Air Combination
Attachments
Check Valve (K): 1/8, 1/4, 3/8
A check valve with intermediate air release port can be easily Bypass port size for
installed to prevent a back flow of lubricant when redirecting the redirecting air flow
E
air flow and releasing the air on the outlet side of the regulator.

C
IN OUT

Check valve

D
A

JIS Symbol

B
Specifications
Model Effective area (mm2)
AKM2000 28
AKM3000 55
Model Bypass A B C D E Applicable model
AKM4000 111 port size
Be sure to use above check valves when redirecting the air flow AKM2000 1/8, 1/4 40 40 28 11 11 ACG20/ACG20A
on the inlet side of the lubricator. Threads for IN and OUT ports
are not machined. AKM3000 1/8, 1/4 53 48 34 14 13 ACG30/ACG30A
AKM4000 1/4, 3/8 70 54 42 18 15 ACG40/ACG40A
How to Order ∗ Refer to the attachment table on page 4 or 7 for standard bypass port sizes
applicable to ACG.

AKM 30 00 01
Check valve Bypass port size for
redirecting air flow
Body size Body size
Port
Symbol
20 30 40 size 20 30 40
01 1/8 앬 앬 —
02 1/4 앬 앬 앬
03 3/8 — — 앬

Thread type
- Rc
N NPT
F G

15
Series ACG

Pressure Switch (S)


A compact integrated pressure switch can be easily installed and

Approx. 500
facilitates the pressure detection of the line.
23 15

Pressure switch

C
B
JIS Symbol

Centre of
F.R.L. body
D A

Specifications
Fluid Air Model A B C D Applicable model
Proof pressure 1.0 MPa IS1000M-20 11 76 66 28 ACG20/ACG20B/ACG20C
Maximum operating pressure 0.7 MPa IS1000M-30 13 86 72 30 ACG30/ACG30B/ACG30C
Regulating pressure range (when off) 0.1 to 0.4 MPa IS1000M-40 15 95 77 36 ACG40/ACG40B/ACG40C
Differential 0.08 MPa Note 1) Separate spacers are required for modular unit.
Note 2) Pressure switch cannot be mounted on the inlet and outlet sides of an ARG
Ambient and fluid temperature –5 to 60°C (With no freezing)
with an upward facing handle (optional specification: -Y).

Switch Characteristics How to Order


Contact point configuration 1a
Maximum contact point capacity 2 VA(AC), 2 W(DC)
Operating voltage: AC, DC 100 V or less
12 V to 24 VAC, DC : 50 mA
IS1000M 30 X201
Maximum operating current 48 VAC, DC : 40 mA Accessory
Pressure switch
100 VAC, DC : 20 mA X201 Lead wire length: 3 m
Body size
Regulating pressure
20 For ACG20 X202 range: 0.1 to 0.6 MPa
30 For ACG30
X207∗ MPa/PSI dual scale
40 For ACG40
Lead wire length: 3 m;
X215 Regulating pressure
range: 0.1 to 0.6 MPa

Note) This product is for overseas


use only according to the
new Measurement Law.
(The SI unit type is provided
for use in Japan.)

16
Attachments Series ACG

Residual Pressure Relief 3 Port Valve (V)


With the use of a 3 port valve for residual pressure release,
pressure left in the line can be easily exhausted. D

3 port valve for


residual pressure release

SUP

A
JIS Symbol
(A) IN OUT
2

B
1 3
(P) (R)
Specifications EXH.
Port size Effective area (mm2) ( ): Effective Area mm2 (Cv)

0
ø1
Model

øI
IN,OUT EXH. INOUT OUTEXH.

2-
1/8 10 (0.54) 11 (0.60)
VHS20 1/8
1/4 14 (0.76) 16 (0.87)
1/4 16 (0.87) 14 (0.76)

G
H

F
VHS30 1/4
3/8 31 (1.68) 29 (1.57)
1/4 27 (1.46) 36 (1.95)
VHS40 3/8 3/8 38 (2.06) 40 (2.17)
E Lockable at the
1/2 55 (2.98) 42 (2.28)
time of exhaust
Note) Use an air filter on the IN side for operating protection. C

How to Order (mm)

Model A B C D E F G H I
VHS 30 03 RZ VHS20 59 20 40 34 — 45 33 28 45
VHS30 78 29 53 46 — 55 42 30 55
Residual pressure
VHS40 107 39 70 63 22 58 44 36 63
relief 3 port valve
Caution
Body size
1. Consult with SMC when a pressure switch is installed on the
Symbol Applicable model outlet of pressure release valve.
20 ACG20 2. If a stop valve or a silencer is connected to the exhaust port of
30 ACG30 VHS20/30, the effective sectional area should be larger than
40 ACG40 the figure indicated in the following table, to prevent
malfunction caused by back pressure. (This is not applicable
to VHS40)
Thread type
Model Effective area (mm2)
- Rc
VHS20 5
N NPT
VHS30 5
F G
Option
Code Description
Port size R Flow direction: Right  Left
Body size Z (1) Name plate in imperial units (PSI, °F)
Symbol Port
size 20 30 40 Note 1) Only for the NPT thread.
01 1/8 앬 — — This product is for overseas use only
according to the new Measurement Law.
02 1/4 앬 앬 앬 (The SI unit type is provided for use in Japan.)
03 3/8 — 앬 앬
04 1/2 — — 앬

17
Series AC
Spacers and Brackets
Accessories
Spacer (X)

D
Centre of
F.R.L. body

C
1
X-X

B
RELEASE
X
Y200 Y400 2

X
Model A B C D Applicable model
Seal
Y200 3 35.5 18.5 48 ACG20
Y300 4 47 26 59 ACG30
Y400 5 57 31 65 ACG40
A
Spacer width
Replacement Parts
Part no.
Description Material
Y200 Y300 Y400
Seal HNBR Y200P-060S Y300P-060S Y400P-060S

Spacer with Bracket (Z)


øG

Center of
F.R.L. body
C
E

BB (Y200T only)
1
EE (Y100T, Y200T only)

X-X
RELEASE

X
B

2
E

X
G

Seal

Y200T Y400T
J F
K H A
D Spacer width

Model A B BB C D E EE F G øG H J K Applicable model


Y200T 3 — 67 29 53 24 33 12 5.5 5.5 19 3.2 30 ACG20
Y300T 4 82 — 41 68 35 — 14 7 7 21 4 41 ACG30
Y400T 5 96 — 48 81.5 40 — 18 9 9 26 4 50 ACG40

Replacement Parts
Part no.
Description Material
Y200T Y300T Y400T
Seal HNBR Y200P-060S Y300P-060S Y400P-060S

18
Modular Style
Regulator with Built-in Pressure Gauge
Series ARG
Regulator with Built-in Pressure Model Port size Accessory
Gauge
Series ARG

ARG20 1/8, 1/4

ARG30 1/4, 3/8

ARG40 1/4, 3/8, 1/2 Bracket

Pages 20 to 23 Set nut for changing


Regulator with Built-in Pressure the mounting angle
of pressure gauges
Gauge with Back Flow Mechanism
Series ARGK ARG20K 1/8, 1/4

ARG30K 1/4, 3/8

ARG40K 1/4, 3/8, 1/2

Pages 24 to 28

19
Regulator with Built-in Pressure Gauge

Series ARG20/30/40
How to Order

ARG 20 01 G1
Option
Symbol Description
Body size - —
1 (1) 0.02 to 0.2 MPa setting
Symbol Port size
N Non-relieving type
ARG20 20 1/8
Z (2) Name plate and pressure gauge in imperial units
30 3/8 (PSI)
40 1/2
∗ When more than one specification is required, indicate in
ascending alphanumeric order.
Note 1) Adjusting spring and pressure gauge (full-span 0.3
MPa) are different from those for the standard
Thread type specification.
Symbol Type Outlet pressure may increase by 0.2 MPa or more.
Note 2) For thread type NPT.
- Rc This product is for overseas use only according to
N NPT the new Measurement Law. (The SI unit type is
F G provided for use in Japan.)
Accessory (2)
Port size Symbol Description
ARG40 - —
Port Body size
Symbol H With set nut
size 20 30 40
01 1/8  — —
02 1/4   
03 3/8 —   Accessory (1)
04 1/2 — —  Symbol Description
- —
B With bracket (With nuts)

Mounting Angle of Pressure Gauge


JIS Symbol
Symbol G1 G2 G3 G4
ARG20 to 40
Mounting angle 0° 90° 180° 270°

MPa
Mounting angle IN OUT IN OUT IN OUT IN OUT

MPa
MPa

view P
MPa P P P
US K US K US K US K
H to L OC H to L OC H to L OC H to L OC

∗ Mounting angles other than 45°, 135°, 225° and 315° are available through the Made to Order (page 29).
∗ Possible to change to the optional mounting angles.
For details, refer to back page 6, “Procedure for replacing or changing the mounting angle of a
pressure gauge”.

: Combination available
: Combination not available
Accessory/Optional Combinations : Available only with NPT thread
Combination Applicable
Accessory Option regulator
Symbol
Accessory/Optional specifications B H 1 N Z ARG20 to 40
Accessory

With bracket B

With set nut H


0.02 to 0.2 MPa setting -1
Option

Non-relieving type -N
Name plate and pressure gauge in imperial units (PSI) -Z

20
Regulator with Built-in Pressure Gauge Series ARG20/30/40
Standard Specifications
Model ARG20 ARG30 ARG40
Port size 1/8, 1/4 1/4, 3/8 1/4, 3/8, 1/2
Fluid Air
Proof pressure 1.5 MPa
Maximum operating pressure 1.0 MPa
Regulating pressure range 0.05 to 0.85 MPa
Relief pressure Set pressure + 0.05 MPa (at relief flow rate of 0.1 l/min (ANR))
Ambient and fluid temperature –5° to 60°C (With no freezing)
Construction Relieving type
Weight (kg) 0.31 0.40 0.57

Accessory Part No.


Applicable model
ARG20 ARG30 ARG40
Accessory
Bracket assembly (1) ARG20P-270AS ARG30P-270AS ARG40P-270AS
Set nut ARG20P-260S ARG30P-260S ARG40P-260S
Standard 0 to 1.0 MPa GB2-10AS GB3-10AS GB4-10AS
Pressure
Pressure gauge 0 to 0.3 MPa GB2-3AS GB3-3AS GB4-3AS
gauge display Optional 0 to 150 PSI GB2-P10AS GB3-P10AS GB4-P10AS
range
0 to 45 PSI GB2-P3AS GB3-P3AS GB4-P3AS
Note 1) Assembly includes a bracket and set nuts.

Flow Characteristics (Representative values) Condition: Inlet pressure 0.7 MPa

ARG20 Rc1/4 ARG30 Rc3/8 ARG40 Rc1/2


0.6 0.6 0.6

0.5 0.5 0.5


Outlet pressure (MPa)

Outlet pressure (MPa)

Outlet pressure (MPa)

0.4 0.4 0.4

0.3 0.3 0.3

0.2 0.2 0.2

0.1 0.1 0.1

0 0 0
0 200 400 600 800 0 500 1000 1500 0 1000 2000 3000
Flow rate (l/min (ANR)) Flow rate (l/min (ANR)) Flow rate (l/min (ANR))

Conditions: Inlet pressure 0.7 MPa, Outlet pressure 0.2 MPa,


Pressure Characteristics (Representative values) Flow rate 20 l/min (ANR)

ARG20 ARG30 ARG40


0.25 0.25 0.25
Outlet pressure (MPa)

Outlet pressure (MPa)

Outlet pressure (MPa)

Set point Set point Set point

0.2 0.2 0.2

0.15 0.15 0.15


0 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1 0 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1 0 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1
Inlet pressure (MPa) Inlet pressure (MPa) Inlet pressure (MPa)

21
Series ARG20/30/40

Construction
Specific Product
Precautions
A-A B-B
Be sure to read before handling.
Refer to back pages 1 through to 5 y
for Safety Instructions and
Precautions.
r
Mounting and Adjustment IN OUT

Warning
1. Set the regulator while verifying the q
displayed values of the inlet and outlet
pressure gauges. Turning the regulator t
handle excessively can cause damage to
the internal parts.
2. Do not use tools on the pressure regulator
handle as this may cause damage. It must
be operated manually. w o

i e
Caution
1. Be sure to unlock the handle before u
adjusting the pressure and lock it after
setting the pressure.
Failure to follow this procedure can cause
damage to the handle and the outlet
pressure may fluctuate.
• Pull the pressure regulator handle to
unlock. (You can visually verify this with
the “orange mark” that appears in the B
gap.)
• Push the pressure regulator handle to
lock. When the handle is not easily
locked, turn it left and right a little and
A A
then push it (when the handle is locked,
the “orange mark”, i.e., the gap will
disappear).
P
US K
H to L OC

Orange mark B

2. When using the regulator between a


solenoid valve and an actuator, check the Component Parts
pressure gauge periodically. Material
No. Description Note
ARG20 ARG30 ARG40
1 Body ZDC ADC Platinum silver
2 Bonnet PBT Black
3 Handle POM Black

Replacement Parts
Part no.
No. Description Material
ARG20 ARG30 ARG40
4 Valve Brass, HNBR AR20P-410S AR30P-410S AR40P-410S
5 Diaphragm assembly Weatherability NBR AR20P-150AS AR30P-150AS AR40P-150AS
6 Valve guide assembly POM, NBR AR20P-050AS AR30P-050AS AR40P-050AS
7 Pressure gauge cover PC ARG20P-400S ARG30P-400S ARG40P-400S
8 Pressure gauge — GB2-10AS GB3-10AS GB4-10AS
9 Clip Stainless steel ARG20P-420S ARG30P-420S ARG40P-420S
Note) Only the standard part numbers are listed in the pressure gauges. For the optional part numbers,
refer to page 21.

22
Regulator with Built-in Pressure Gauge Series ARG20/30/40

Dimensions

Panel fitting dimension


K

øJ

IN OUT
øL

øH P
U K
SH
to L O C

Plate thickness
ARG20 to 40: Max. 3.5

F Port size E
D A
C

IN OUT
SMC
G
R
B

Set nut
(Option)
S P

T M
N
Bracket
(Option)

Standard specifications Accessory specifications


Model Port size Panel mount Bracket mount
A B C D E F
G H J K L M N P Q R S T
ARG20 1/8, 1/4 40 114 26.5 57 45 47 38 52.5 39.5 19.5 6 48 65 10.4 5.4 60 2.3 35
ARG30 1/4, 3/8 53 138.5 31 59 58 59 50 65 50.5 25 7 59 75 10.5 6.5 70 2.3 45
ARG40 1/4, 3/8, 1/2 70 150.5 36 68 70 70 54 70 55.5 27.5 7 65.5 85 12.5 8.5 75 2.3 50

23
Regulator with Built-in Pressure Gauge
with Back Flow Mechanism

Series ARG20K/30K/40K How to Order

ARG 20 K 01 G1
Option
Body size Symbol Description
Symbol Port size - —
20 1/8 1 (2) 0.02 to 0.2 MPa setting
30 3/8 N Non-relieving type
ARG20K 40 1/2 Z (3) Name plate and pressure gauge in imperial units
(PSI)
∗ When more than one specification is required, indicate in
With back flow mechanism ascending alphanumeric order.
Note 1) If the set pressure is not Note 2) Adjusting spring and pressure gauge (full-span 0.3 MPa)
exceeding 0.15 MPa, back flow are different from those for the standard specification.
may not occur. Contact SMC Outlet pressure may still be increased from 0.2 MPa or
when a back flow mechanism is more.
required with a set pressure of Note 3) For thread type NPT.
less than 0.15 MPa. This product is for overseas use only according to the
new Measurement Law. (The SI unit type is provided for
Thread type use in Japan.)
Symbol Type
- Rc Accessory (2)
ARG40K N NPT Symbol Description
F G - —
Port size H With set nut

Port Body size


Symbol
size 20 30 40
01 1/8  — — Accessory (1)
02 1/4    Symbol Description
03 3/8 —   - —
04 1/2 — —  B With bracket (With nuts)

Mounting Angle of Pressure Gauge


Symbol G1 G2 G3 G4
JIS Symbol Mounting angle 0° 90° 180° 270°
ARG20K/30K/40K
MPa
Mounting angle IN OUT IN OUT IN OUT IN OUT

MPa
MPa

view MPa
P P P P
US K US K US K US K
H to L OC H to L OC H to L OC H to L OC

∗ Mounting angles other than 45°, 135°, 225° and 315° are available through the Made to Order (page 29).
∗ Possible to change to the optional mounting angles.
For details, refer to back page 6, “Procedure for replacing or changing the mounting angle of a
pressure gauge”.

: Combination available
: Varies depending on a model Application examples of a regulator
Accessory/Optional : Combination not available with a back flow mechanism
Combinations : Available only with NPT thread
With a built-in mechanism which enables reliable
Combination Applicable
Accessory/ Accessory Option regulator discharge of air pressure from outlet to inlet
Optional Symbol
specifications B H 1 N Z ARG20 to 40 Example 1) Example 2)
When the pressure in the When the air supply is cut off and
Accessory

With bracket B rear and the front of the releasing the inlet pressure to the
cylinder differs: atmosphere, the residual pressure release
of the outlet side can be ensured for a
With set nut H safety purpose.
Circuit diagram
0.02 to 0.2 MPa setting -1 Circuit diagram
Option

Non-relieving type -N
Name plate and
pressure gauge in -Z
imperial units (PSI)

24
Regulator with Built-in Pressure Gauge
with Back Flow Mechanism Series ARG20K/30K/40K
Standard Specifications
Model ARG20K ARG30K ARG40K
Port size 1/8, 1/4 1/4, 3/8 1/4, 3/8, 1/2
Fluid Air
Proof pressure 1.5 MPa
Maximum operating pressure 1.0 MPa
Regulating pressure range (1) 0.05 to 0.85 MPa
Relief pressure Set pressure + 0.05 MPa (at relief flow rate of 0.1 l/min (ANR))
Ambient and fluid temperature –5° to 60°C (With no freezing)
Construction Relieving type
Weight (kg) 0.31 0.40 0.57
Note 1) Set the inlet pressure to 0.05 MPa or higher than the set pressure.

Accessory Part No.


Applicable model
ARG20K ARG30K ARG40K
Accessory
Bracket assembly (1) ARG20P-270AS ARG30P-270AS ARG40P-270AS
Set nut ARG20P-260S ARG30P-260S ARG40P-260S
Standard 0 to 1.0 MPa GB2-10AS GB3-10AS GB4-10AS
Pressure
Pressure gauge 0 to 0.3 MPa GB2-3AS GB3-3AS GB4-3AS
gauge display Optional 0 to 150 PSI GB2-P10AS GB3-P10AS GB4-P10AS
range
0 to 45 PSI GB2-P3AS GB3-P3AS GB4-P3AS
Note 1) Assembly includes a bracket and set nuts.

Flow Characteristics (Representative values) Condition: Inlet pressure 0.7 MPa

ARG20K Rc1/4 ARG30K Rc3/8 ARG40K Rc1/2


0.6 0.6 0.6

0.5 0.5 0.5


Outlet pressure (MPa)

Outlet pressure (MPa)

Outlet pressure (MPa)

0.4 0.4 0.4

0.3 0.3 0.3

0.2 0.2 0.2

0.1 0.1 0.1

0 0 0
0 200 400 600 800 0 500 1000 1500 1000 2000 3000
Flow rate (l/min (ANR)) Flow rate (l/min (ANR)) Flow rate (l/min (ANR))

Conditions: Inlet pressure 0.7 MPa, Outlet pressure 0.2 MPa,


Pressure Characteristics (Representative values) Flow rate 20 l/min (ANR)

ARG20K ARG30K ARG40K


0.25 0.25 0.25
Outlet pressure (MPa)

Outlet pressure (MPa)

Outlet pressure (MPa)

Set point Set point Set point

0.2 0.2 0.2

0.15 0.15 0.15


0 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1 0 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1 0 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1
Inlet pressure (MPa) Inlet pressure (MPa) Inlet pressure (MPa)

25
Series ARG20K/30K/40K

Working Principle
Specific Product
A-A
A w Precautions
Be sure to read before handling.
Refer to back pages 1 through to 5
for Safety Instructions and Precau-
OUT

tions.
1
IN

SMC Mounting and Adjustment


Warning
1. Set the regulator while verifying the
A displayed values of the inlet and outlet
pressure gauges. Turning the regulator
handle excessively can cause damage to
the internal parts.
2. Do not use tools on the pressure regulator
handle as this may cause damage. It must
be operated manually.
r

IN OUT Figure 1 Caution


(Inlet pressure) (Outlet pressure) w Normal 1. Be sure to unlock the handle before
adjusting the pressure and lock it after
q setting the pressure.
Failure to follow this procedure can cause
e Inlet pressure Pressure in
(IN) diaphragm chamber
damage to the handle and the outlet
pressure may fluctuate.

Figure 3

Figure 2
Orange mark
Back flow

IN OUT
(Inlet pressure) (Outlet pressure)
Inlet pressure Pressure in
(IN) diaphragm chamber
• Pull the pressure regulator handle to
unlock. (You can visually verify this with
the “orange mark” that appears in the
gap.)
• Push the pressure regulator handle to
lock. When the handle is not easily
locked, turn it left and right a little and
When the inlet pressure (P1) is higher than the regulating pressure, the check valve then push it (when the handle is locked,
the “orange mark”, i.e., the gap will
w closes and operates as a normal regulator (Figure 1).
disappear).
When the inlet pressure (P1) is shut off and released, the check valve w opens and
the pressure in the diaphragm chamber q is released into the inlet side (Figure 2).
This lowers the pressure in the diaphragm chamber q and the force generated by the
pressure regulator spring e lifts the diaphragm. Valve r opens through the stem, Maintenance
and the outlet pressure is released to the inlet side (Figure 3).
Warning
1. When using the regulator between a
solenoid valve and an actuator, check the
pressure gauge periodically.
Sudden pressure fluctuations may shorten
the durability of the pressure gauge.

26
Regulator with Built-in Pressure Gauge
with Back Flow Mechanism Series ARG20K/30K/40K

Construction

B-B
A-A
y

IN OUT

q
!0
t

i e o

A A

P
US K
H to L O C

Component Parts
Material
No. Description Note
ARG20 ARG30 ARG40
1 Body ZDC ADC Platinum silver
2 Bonnet PBT Black
3 Handle POM Black

Replacement Parts
Part no.
No. Description Material
ARG20 ARG30 ARG40
4 Valve Brass, HNBR AR20P-410S AR30P-410S AR40P-410S
5 Diaphragm assembly Weatherability NBR AR20P-150AS AR30P-150AS AR40P-150AS
6 Valve guide assembly POM, NBR AR20P-050AS AR30P-050AS AR40P-050AS
7 Pressure gauge cover PC ARG20P-400S ARG30P-400S ARG40P-400S
8 Pressure gauge (1) — GB2-10AS GB3-10AS GB4-10AS
9 Clip Stainless steel ARG20P-420S ARG30P-420S ARG40P-420S
10 Check valve assembly (2) — AR20KP-020AS
Note 1) Only the standard part numbers are listed for the pressure gauges. For the optional part numbers, refer to page 25.
Note 2) Check valve assembly contains check valve, check valve cover and its screws (2 pcs).
27
Series ARG20K/30K/40K

Construction

Panel fitting dimension


K

øJ
IN OUT
øL

øH
P
US K
H to L O C

Plate thickness
ARG20K to 40K: Max. 3.5

F Port size E
D A
C

IN OUT
SMC
G
R
B

Set nut
(Option)
S P

T M
N
Bracket
(Option)

Standard specifications Accessory specifications


Model Port size Panel mount Bracket mount
A B C D E F
G H J K L M N P Q R S T
ARG20K 1/8, 1/4 40 114 26.5 57 45 47 38 52.5 39.5 19.5 6 48 65 10.4 5.4 60 2.3 35
ARG30K 1/4, 3/8 53 138.5 31 59 58 59 50 65 50.5 25 7 59 75 10.5 6.5 70 2.3 45
ARG40K 1/4, 3/8, 1/2 70 150.5 36 68 70 70 54 70 55.5 27.5 7 65.5 85 12.5 8.5 75 2.3 50

28
Regulator with Built-in Pressure Gauge
ARG20/30/40
Made to Order
Contact SMC for detailed dimensions, specifications, and lead times.

q Special Mounting Angle Specification of Pressure Gauge (45°, 135°, 225°, 315°)

ARG 20 01 G5 X2101 A
Mounting angle of
Body size pressure gauge
Symbol Port size
Symbol Description
20 1/8
A 45°
30 3/8
B 135°
40 1/2
C 225°
D 315°
With back flow mechanism ∗ Refer to the table below.
Symbol Description
Option
- —
(1) Symbol Description
K With back flow mechanism
- —
Note 1) If the set pressure is not
exceeding 0.15 MPa, back
1 (2) 0.02 to 0.2 MPa setting
flow may not occur. Contact N Non-relieving type
SMC when a back flow Z (3) Name plate and pressure gauge in imperial units
mechanism is required with a (PSI)
set pressure of less than 0.15
MPa. ∗ When more than one specification is required, indicate in
ascending alphanumeric order.
Note 2) Adjusting spring and pressure gauge (full-span 0.3 MPa)
are different from those for the standard specification.
Thread type Outlet pressure may still be increased from 0.2 MPa or
Symbol Type more.
- Rc Note 3) For thread type NPT.
This product is for overseas use only according to the
N NPT Accessory (2) new Measurement Law. (The SI unit type is provided for
F G Symbol Description use in Japan.)
- —

Port size H With set nut

Port Body size


Symbol
size 20 30 40
Special mounting specification of pressure gauge
01 1/8  — —
02 1/4    Accessory (1)
03 3/8 —   Symbol Description
04 1/2 — —  - —
B With bracket (With nuts)

Mounting Angle of Pressure Gauge


Symbol X2101A X2101B X2101C X2101D
Mounting angle 45° 135° 225° 315°
Name plate position Name plate position

45° 13 22 31
5° 5° 5°
MP

a
Mounting angle IN OUT IN OUT IN MP OUT IN OUT
a

MP
view
a

a
MP

P P P P
US K US K US K US K
C C C C
H to L O H to L O H to L O H to L O

Name plate position Name plate position

: Combination available
: Combination not available
Accessory/Optional Combinations : Available only with NPT thread
Combination Applicable
Accessory Option regulator
Symbol
Accessory/Optional specifications B H 1 N Z ARG20 to 40
Accessory

With bracket B

With set nut H

0.02 to 0.2 MPa setting -1


Option

Non-relieving type -N
Name plate and pressure gauge in imperial units (PSI) -Z
29
Modular Style
Filter Regulator with Built-in Pressure Gauge
Series AWG
Filter Regulator with Built-in Nominal
Pressure Gauge Model Port size filtration Accessory
rating
Series AWG

AWG20 1/8, 1/4

AWG30 1/4, 3/8

Bracket
AWG40 1/4, 3/8, 1/2
Float type auto-drain
Pages 30 to 33
5 µm
Filter Regulator with Built-in Set nut for changing the
Pressure Gauge with Back Flow mounting angle of
Mechanism AWG20K 1/8, 1/4 pressure gauges
Series AWGK

AWG30K 1/4, 3/8

AWG40K 1/4, 3/8, 1/2

Pages 34 to 38

30
Filter Regulator with Built-in Pressure Gauge

Series AWG20/30/40
How to Order

AWG 30 03 G1 AWG20 AWG40

Option
Body size Symbol Description Applicable model
Symbol Port size - — —
20 1/8 1 (4) 0.02 to 0.2 MPa setting AWG20 to 40
30 3/8 2 Metal bowl AWG20 to 40
40 1/2 6 Nylon bowl AWG20 to 40
8 Metal bowl with level gauge AWG30, 40
C With bowl guard AWG20
Thread type J (5) With drain guide AWG20 to 40
Symbol Type N Non-relieving AWG20 to 40
- (1) Rc W Drain cock with barb fitting: ø6 x ø4 nylon tubing AWG30, 40
N (2)
NPT Z (6) Name plate, caution plate for bowl, and pressure gauge in imperial units (PSI, °F) AWG20 to 40
(3)
F G ∗ When more than one specification is required, indicate in ascending alphanumeric
Note 1) Drain guide is Rc1/8 for AWG20 order.
Note 4) Adjusting spring and pressure gauge (full-span 0.3 MPa) are different from
and Rc1/4 for AWG30 and 40.
those for the standard specification.
Note 2) Drain guide is NPT1/8 for AWG20
and NPT1/4 for AWG30 and 40. Outlet pressure may still be increased from 0.2 MPa or more.
Auto-drain port is provided with Note 5) Without a valve function.
ø3.8" One-touch fitting (applicable Note 6) For thread type NPT.
This product is for overseas use only according to the new Measurement
to AWG30 and 40).
Law. (The SI unit type is provided for use in Japan.)
Note 3) Drain guide is G1/8 for AWG20
and G1/4 for ACG30 and 40. Accessory (2)
Symbol Description Applicable model
- — —
H With set nut AWG20 to 40

Port size Accessory (1)


Symbol Description Applicable model
Port Body size
Symbol - — —
size 20 30 40
B With bracket (With nuts) AWG20 to 40
01 1/8  — — C Float type auto-drain (Normally closed) AWG20 to 40
02 1/4    D Float type auto-drain (Normally open) AWG30, 40
03 3/8 —   When more than one specification is required, indicate in ascending alphabetical order.
04 1/2 — — 
Mounting Angle of Pressure Gauge
JIS Symbol Symbol G1 G2 G3 G4
AWG20/30/40 Mounting angle 0° 90° 180° 270°

MPa
IN OUT IN OUT IN OUT IN OUT
MPa
MPa

Mounting angle
view P
MPa P P P
US K US K US K US K
H to L OC H to L OC H to L OC H to L OC

∗ Possible to change to the optional mounting angles.


For details, refer to back page 6, “Procedure for replacing or changing the mounting angle of a previous
gauge”.
: Combination available : Combination not available
Accessory/Optional Combinations : Varies depending on a model : Available only with NPT thread
Symbol

Combination Accessory Option Applicable filter regulator


Accessory/Optional specifications B C D H 1 2 6 8 C J N W Z AWG20 AWG30/40
With bracket B
Accessory

Float type auto-drain (Normally closed) C


Float type auto-drain (Normally open) D
With set nut H
0.02 to 0.2 MPa setting -1
Metal bowl -2
Nylon bowl -6
Metal bowl with level gauge -8
Option

With bowl guard -C


Drain guide -J
Non-relieving type -N
Drain cock with barb fitting -W
Name plate, caution plate for bowl, and
pressure gauge in imperial units (PSI, °F) -Z

31
Series AWG20/30/40
Standard Specifications
Model AWG20 AWG30 AWG40
Port size 1/8, 1/4 1/4, 3/8 1/4, 3/8, 1/2
Fluid Air
Proof pressure 1.5 MPa
Maximum operating pressure 1.0 MPa
Regulating pressure range 0.05 to 0.85 MPa
Relief pressure Set pressure + 0.05 MPa (at relief flow rate of 0.1 l/min (ANR))
Ambient and fluid temperature –5 to 60°C (With no freezing)
Nominal filtration rating 5 µm
Drain capacity (cm3) 8 25 45
Bowl material Polycarbonate
Bowl guard Optional Standard
Construction Relieving type
Weight (kg) 0.38 0.51 0.86

Accessory Part No.


Applicable model
AWG20 AWG30 AWG40
Accessory
(1)
Bracket assembly ARG20P-270AS ARG30P-270AS ARG40P-270AS
Set nut ARG20P-260S ARG30P-260S ARG40P-260S
Standard 0 to 1.0 MPa GB2-10AS GB3-10AS GB4-10AS
Pressure
Pressure gauge 0 to 0.3 MPa GB2-3AS GB3-3AS GB4-3AS
gauge display Optional 0 to 150 PSI GB2-P10AS GB3-P10AS GB4-P10AS
range
0 to 45 PSI GB2-P3AS GB3-P3AS GB4-P3AS
(2) Normally open — AD38 AD48
Float type auto-drain
Normally closed AD27 AD37 AD47
Note 1) Assembly includes a bracket and set nuts.
Note 2) Minimum operating pressure: N.O. type–0.1 MPa; N.C. type–0.1 MPa (AD27) and 0.15 MPa (AD37/47). Contact SMC regarding the specifications for PSI unit and °F.

Flow Characteristics (Representative values) Condition: Inlet pressure 0.7 MPa

AWG20 Rc1/4 AWG30 Rc3/8 AWG40 Rc1/2


0.6 0.6 0.6

0.5 0.5 0.5


Outlet pressure (MPa)

Outlet pressure (MPa)

Outlet pressure (MPa)

0.4 0.4 0.4

0.3 0.3 0.3

0.2 0.2 0.2

0.1 0.1 0.1

0 0 0
0 200 400 600 800 0 500 1000 1500 0 1000 2000 3000
Flow rate (l/min (ANR)) Flow rate (l/min (ANR)) Flow rate (l/min (ANR))

Conditions: Inlet pressure 0.7 MPa, Outlet pressure 0.2 MPa,


Pressure Characteristics (Representative values) Flow rate 20 l/min (ANR)

AWG20 AWG30 AWG40


0.25 0.25 0.25
Outlet pressure (MPa)

Outlet pressure (MPa)

Outlet pressure (MPa)

Set point Set point Set point

0.2 0.2 0.2

0.15 0.15 0.15


0 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1 0 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1 0 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1
Inlet pressure (MPa) Inlet pressure (MPa) Inlet pressure (MPa)

32
Filter Regulator with Built-in Pressure Gauge Series ARG20/30/40

Construction
AWG20 B AWG30/40 D

P
US K P
A H to L OC
A C US
H to L O C
K
C

B D
!0
!0 C-C D-D
A-A B-B o
o !1
e
e !1
w
w
y
y
q q
IN OUT
IN OUT

u
u
r
r
t t
i i

Component Parts Replacement Parts


Material Part no.
No. Description Note No. Description Material
AWG20 AWG30 AWG40 AWG20 AWG30 AWG40
1 Body ZDC ADC Platinum silver 4 Valve assembly Brass, HNBR AW20P-340AS AW30P-340AS AW40P-340AS
2 Bonnet PBT Black 5 Filter element Non-woven fabric AF20P-060S AF30P-060S AF40P-060S
3 Handle POM Black 6 Diaphragm assembly Weatherability NBR AR20P-150AS AR30P-150AS AR40P-150AS
7 Bowl O-ring NBR C2SFP-260S C3SFP-260S C4SFP-260S
8 Bowl assembly (1) PC C2SF C3SF (2) C4SF (2)
9 Pressure gauge (3) — GB2-10AS GB3-10AS GB4-10AS
10 Pressure gauge cover PC ARG20P-400S ARG30P-400S ARG40P-400S
11 Clip Stainless steel ARG20P-420S ARG30P-420S ARG40P-420S
Note 1) Including O-ring. Contact SMC regarding the bowl assembly supply for PSI and °F unit
specifications.
Note 2) Bowl assembly includes a bowl guard (steel band material).
Note 3) Only the standard part numbers are listed in the pressure gauges. For the optional part
numbers, refer to page 32.

Specific Product Precautions


Be sure to read before handling. Refer to back pages 1 through to 5 for Safety Instructions and Precautions.

Selection Mounting and Adjustment

Warning Warning • Pull the pressure regulator handle to


1. Residual pressure release (outlet 1. Set the regulator while checking the unlock. (You can visually verify this
pressure release) is not completed by displayed values of the inlet and outlet with the “orange mark” that appears in
releasing inlet pressure. To release pressure gauges. Turning the handle the gap.)
residual pressure, use a filter regulator excessively can cause damage to the • Push the pressure regulator handle to
with a back flow mechanism. internal parts. lock. When the handle is not easily lo-
2. Do not use tools on the pressure cked, turn it left and right a little and
regulator handle as this may cause then push it (when the handle is lo-
damage. It must be operated manually. cked, the “orange mark” will disap-
Maintenance pear).
Caution Orange mark
Warning 1. Be sure to unlock the handle before
1. Replace the element every 2 years or adjusting the pressure and lock it after
when the pressure drop becomes 0.1 setting the pressure.
MPa, whichever comes first, to prevent Failure to follow this procedure can
damage to the element. cause damage to the handle and the
outlet pressure may fluctuate.

33
Series AWG20/30/40

Dimensions

AWG20 Q
G Bracket øW Panel fitting dimension
J (Option) K U

øT
R P
IN OUT

øV
N
C
M
Plate thickness
S
Set nut AWG20: Max. 3.5
(Option) IN SMC OUT
B
OUT

Port size

S O O S

Min. clearance Drain


H

for maintenance
D A
E

AWG30/40
Q
G Bracket øW Panel fitting dimension
J (Option) K
U

øT
R P
IN OUT
øV
N
C
M

Set nut
S

Plate thickness
(Option) AWG30/40: Max. 3.5
IN SMC OUT
B

OUT

Port size

Min. clearance D Drain


H

for maintenance A
E

Applicable model AWG20 AWG30/40


Accessory/Optional
specifications With auto-drain (N.C.) Metal bowl With drain guide With auto-drain (N.O./N.C.) Metal bowl Metal bowl with level gauge With drain guide Drain cock with barb fitting
B

B
B

B
B
B

Dimensions N.O.: Black


B

OS N.C.: Gray
1/8
O
S
ø10 One-touch 1/4 Barb fitting
M5 fitting Applicable tubing: T0604
Width across flats 17 Width across flats 17

Standard specifications Accessory specifications


Model Port size Bracket mount
A B C D E G H
J K M N P Q R
AWG20 1/8, 1/4 40 179 91 52 45 47 40 35 48 65 5.4 10.4 65 2.3
AWG30 1/4, 3/8 53 223.5 108.5 59 58 59 55 45 58.5 70 6.5 10.5 75 2.3
AWG40 1/4, 3/8, 1/2 70 261.5 114.5 75 70 70 80 50 70 77 8.5 12.5 85 2.3

Accessory specifications Optional specifications


Model Panel mount With auto-drain With barb fitting With drain guide Metal bowl Metal bowl with level gauge
S T U V W B B B B B
AWG20 43 39.5 19.5 6 52.5 196 — 183 179 —
AWG30 50 50.5 25 7 65 264 231.5 230.5 236.5 256.5
AWG40 56 55.5 27.5 7 70 300 269.5 268.5 274.5 294.5

34
Filter Regulator with Built-in Pressure Gauge
with Back Flow Mechanism

Series AWG20K/30K/40K How to Order

AWG 30 K 03 G1
AWG20K AWG40K
Option
Body size Symbol Description Applicable model
Symbol Port size - — —
20 1/8 1 (5) 0.02 to 0.2 MPa setting AWG20K to 40K
30 3/8 2 Metal bowl AWG20K to 40K
40 1/2 6 Nylon bowl AWG20K to 40K
8 Metal bowl with level gauge AWG30K, 40K
C With bowl guard AWG20K
With back flow mechanism J (6) With drain guide AWG20K to 40K
Note 1) If the set pressure is not N Non-relieving AWG20K to 40K
exceeding 0.15 MPa, back
flow may not occur. Contact W Drain cock with barb fitting: ø6 x ø4 nylon tubing AWG30K, 40K
SMC when a back flow Z (7) Name plate, caution plate for bowl, and pressure gauge in imperial units (PSI, °F) AWG20K to 40K
mechanism is required with a ∗ When more than one specification is required, indicate in ascending alphanumeric
set pressure of less than 0.15 order.
MPa. Note 5) Adjusting spring and pressure gauge (full-span 0.3 MPa) are different from
those for the standard specification.
Thread type Outlet pressure may still be increased from 0.2 MPa or more.
Note 6) Without a valve function.
Symbol Type Note 7) For thread type NPT.
- (2) Rc This product is for overseas use only according to the new Measurement
(3) Law. (The SI unit type is provided for use in Japan.)
N NPT
F (4)
G Accessory (2)
Note 2) Drain guide is Rc1/8 for AWG20K Symbol Description Applicable model
and Rc1/4 for AWG30K and 40K. - — —
Note 3) Drain guide is NPT1/8 for AWG20K H With set nut AWG20K to 40K
and NPT1/4 for AWG30K and 40K.
Auto-drain port is provided with
ø3.8" One-touch fitting (applicable Accessory (1)
to AWG30K and 40K).
Note 4) Drain guide is G1/8 for AWG20K Symbol Description Applicable model
and G1/4 for ACG30K and 40K. - — —
B With bracket (With nuts) AWG20K to 40K
C Float type auto-drain (Normally closed) AWG20K to 40K
Port size D Float type auto-drain (Normally open) AWG30K, 40K
Port Body size When more than one specification is required, indicate in ascending alphabetical order.
Symbol
size 20 30 40
Mounting Angle of Pressure Gauge
01 1/8  — —
Symbol G1 G2 G3 G4
02 1/4   
Mounting angle 0° 90° 180° 270°
03 3/8 —  
04 1/2 — — 
MPa
Mounting angle IN OUT IN OUT IN OUT IN OUT
MPa
MPa

view MPa
JIS Symbol P
US
H to L OC
K
P
US
H to L OC
K
P
US
H to L OC
K
P
US
H to L OC
K

AWG20K/30K/40K
∗ Possible to change to the optional mounting angles.
For details, refer to back page 6, “Procedure for replacing or changing the mounting angle of a
pressure gauge”.
Accessory/ : Combination available : Combination not available
Optional Combinations : Varies depending on a model : Available only with NPT thread
Symbol

Combination Accessory Option Applicable filter regulator


Accessory/Optional
specifications B C D H 1 2 6 8 C J N W Z AWG20K AWG30K/40K
With bracket B
Accessory

Application example of a Float type auto-drain (N.C.) C


filter regulator with a Float type auto-drain (N.O.) D
back flow mechanism With set nut H
When the air supply is cut off and releasing 0.02 to 0.2 MPa setting -1
the inlet pressure to the atmosphere, the Metal bowl -2
residual pressure release of the outlet side
can be ensured for a safety purpose. Nylon bowl -6
Metal bowl with level gauge -8
Option

Symbol With bowl guard -C


Drain guide 1/4 -J
Non-relieving type -N
Filter regulator Drain cock with barb fitting -W
with back flow Name plate, caution plate for
mechanism bowl, and pressure gauge in -Z
imperial units (PSI, °F)

35
Series AWG20K/30K/40K
Standard Specifications
Model AWG20K AWG30K AWG40K
Port sizes 1/8, 1/4 1/4, 3/8 1/4, 3/8, 1/2
Fluid Air
Proof pressure 1.5 MPa
Maximum operating pressure 1.0 MPa
Regulating pressure range (1) 0.05 to 0.85 MPa
Relief pressure Set pressure + 0.05 MPa (at relief flow rate of 0.1 l/min (ANR))
Ambient and fluid temperature –5 to 60°C (With no freezing)
Nominal filtration rating 5 µm
Drain capacity (cm3) 8 25 45
Bowl material Polycarbonate
Bowl guard Optional Standard
Construction Relieving type
Weight (kg) 0.38 0.51 0.86
Note 1) Set the inlet pressure so it should be 0.05 MPa or higher than the set pressure.

Accessory Part No.


Applicable model
AWG20K AWG30K AWG40K
Accessory
(1)
Bracket assembly ARG20P-270AS ARG30P-270AS ARG40P-270AS
Set nut ARG20P-260S ARG30P-260S ARG40P-260S
Standard 0 to 1.0 MPa GB2-10AS GB3-10AS GB4-10AS
Pressure
Pressure gauge 0 to 0.3 MPa GB2-3AS GB3-3AS GB4-3AS
gauge display Optional 0 to 150 PSI GB2-P10AS GB3-P10AS GB4-P10AS
range
0 to 45 PSI GB2-P3AS GB3-P3AS GB4-P3AS
Normally open — AD38 AD48
Float type auto-drain (2)
Normally closed AD27 AD37 AD47
Note 1) Assembly includes a bracket and set nuts.
Note 2) Minimum operating pressure: N.O. type–0.1 MPa; N.C. type–0.1 MPa (AD27) and 0.15 MPa (AD37/47). Contact SMC regarding the specifications for PSI unit and °F.

Flow Characteristics (Representative values) Condition: Inlet pressure 0.7 MPa

AWG20K Rc1/4 AWG30K Rc3/8 AWG40K Rc1/2


0.6 0.6 0.6

0.5 0.5 0.5


Outlet pressure (MPa)

Outlet pressure (MPa)

Outlet pressure (MPa)

0.4 0.4 0.4

0.3 0.3 0.3

0.2 0.2 0.2

0.1 0.1 0.1

0 0 0
0 200 400 600 800 0 500 1000 1500 0 1000 2000 3000
Flow rate (l/min (ANR)) Flow rate (l/min (ANR)) Flow rate (l/min (ANR))

Conditions: Inlet pressure 0.7 MPa, Outlet pressure 0.2 MPa,


Pressure Characteristics (Representative values) Flow rate 20 l/min (ANR)

AWG20K AWG30K AWG40K


0.25 0.25 0.25
Outlet pressure (MPa)

Outlet pressure (MPa)

Outlet pressure (MPa)

Set point Set point Set point

0.2 0.2 0.2

0.15 0.15 0.15


0 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1 0 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1 0 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1
Inlet pressure (MPa) Inlet pressure (MPa) Inlet pressure (MPa)

36
Filter Regulator with Built-in Pressure Gauge
with Back Flow Mechanism Series AWG20K/30K/40K

Working Principle

A-A w

P
U K
SH C
to L O

Figure 1
A Normal

Figure 3

e
Pressure in Inlet
q diaphragm
chamber
pressure
(IN)

IN OUT IN OUT Figure 2


(Inlet (Outlet (Inlet (Outlet
pressure) pressure) pressure) pressure) Back flow

r
Pressure in Inlet
diaphragm pressure
chamber (IN)
When the inlet pressure (P1) is higher than the regulating pressure, the check valve w closes and operates as a
normal regulator (Figure 1).
When the inlet pressure (P1) is shut off and released, the check valve w opens and the pressure in the diaphragm
chamber q is released into the inlet side (Figure 2).
This lowers the pressure in the diaphragm chamber q and the force generated by the pressure regulator spring e
lifts the diaphragm. Valve r opens through the stem, and the outlet pressure is released to the inlet side (Figure 3).

Specific Product Precautions


Be sure to read before handling. Refer to back pages 1 through to 5 for Safety Instructions and Precautions.

Maintenance Mounting and Adjustment


Warning Warning • Push the pressure regulator handle to
1. Replace the element every 2 years or 1. Set the regulator while checking the lock. When the handle is not easily lo-
when the pressure drop becomes 0.1 displayed values of the inlet and outlet cked, turn it left and right a little and
MPa, whichever comes first, to prevent pressure gauges. Turning the handle then push it (when the handle is lo-
damage to the element. excessively can cause damage to the cked, the “orange mark” will disap-
internal parts. pear).
2. Do not use tools on the pressure
regulator handle as this may cause
damage. It must be operated manually. Orange mark

Caution
1. Be sure to unlock the handle before
adjusting the pressure and lock it after
setting the pressure.
Failure to follow this procedure can
cause damage to the handle and the
outlet pressure may fluctuate.
• Pull the pressure regulator handle to
unlock. (You can visually verify this
with the “orange mark” that appears in
the gap.)

37
Series AWG20K/30K/40K

Construction
AWG20K AWG30K/40K
B D

P
US K C P C
A H to L O C A U
SH K
to L O C

B D

C-C D-D

A-A B-B
!0
!0 o !1
o !1 e
e w
w y
y q
q !2 !2
IN OUT IN OUT

u u
r r
t t
i i

Component Parts
Material
No. Description Note
AWG20K AWG30K AWG40K
1 Body ZDC ADC Platinum silver
2 Bonnet PBT Black
3 Handle POM Black

Replacement Parts
Part no.
No. Description Material
AWG20K AWG30K AWG40K
4 Valve assembly Brass, HNBR AW20P-340AS AW30P-340AS AW40P-340AS
5 Filter element Non-woven fabric AF20P-060S AF30P-060S AF40P-060S
6 Diaphragm assembly Weatherability NBR AR20P-150AS AR30P-150AS AR40P-150AS
7 Bowl O-ring NBR C2SFP-260S C3SFP-260S C4SFP-260S
8 Bowl assembly (1) PC C2SF C3SF (2) C4SF (2)
(3)
9 Pressure gauge — GB2-10AS GB3-10AS GB4-10AS
10 Pressure gauge cover PC ARG20P-400S ARG30P-400S ARG40P-400S
11 Clip Stainless steel ARG20P-420S ARG30P-420S ARG40P-420S
12 Check valve assembly — AR20KP-020AS
Note 1) Including O-ring. Contact SMC regarding the bowl assembly supply for PSI and °F unit specifications.
Note 2) Bowl assembly (AWG30K/40K) includes a bowl guard (steel band material).
Note 3) Only the standard part numbers are listed for the pressure gauges. For the optional part numbers, refer to page 36.

38
Filter Regulator with Built-in Pressure Gauge
with Back Flow Mechanism Series AWG20K/30K/40K

Dimensions

AWG20K Bracket Q
G (Option) øW Panel fitting dimension
J K U

øT
R P
IN OUT

øV
N
C
M Plate thickness
S

Set nut AWG20K: Max. 3.5


(Option) IN SMC OUT
B
OUT

Port size

S O O S
Drain
H

Min. clearance
D A
for maintenance
E

AWG30K/40K Q
Bracket
G (Option) øW Panel fitting dimension
J K
U

øT
R P
IN OUT
øV
N
C
M

Set nut Plate thickness


S

(Option) AWG30K/40K: Max. 3.5


IN SMC OUT
B

OUT

Port size

Drain
Min. clearance
H

for maintenance D A
E

Applicable model AWG20K AWG30K/40K


Accessory/Optional
specifications With auto-drain (N.C.) Metal bowl With drain guide With auto-drain (N.O./N.C.) Metal bowl Metal bowl with level gauge With drain guide Drain cock with barb fitting
B

B
B
B

Dimensions N.O.: Black


B

N.C.: Gray
OS
1/8
O
S
ø10 One-touch Width 1/4 Barb fitting
M5 fitting across flats 17 Applicable tubing: T0604
Width across flats 17

Standard specifications Accessory specifications


Model Port size Bracket mount
A B C D E G H
J K M N P Q R
AWG20K 1/8, 1/4 40 179 91 52 45 47 40 35 48 65 5.4 10.4 65 2.3
AWG30K 1/4, 3/8 53 223.5 108.5 59 58 59 55 45 58.5 70 6.5 10.5 75 2.3
AWG40K 1/4, 3/8, 1/2 70 261.5 114.5 75 70 70 80 50 70 77 8.5 12.5 85 2.3

Accessory specifications Optiional specifications


Model Panel mount With auto-drain With barb fitting With drain guide Metal bowl Metal bowl with level gauge
S T U V W B B B B B
AWG20K 43 39.5 19.5 6 52.5 196 — 183 179 —
AWG30K 50 50.5 25 7 65 264 231.5 230.5 256.5 276.5
AWG40K 56 55.5 27.5 7 70 300 269.5 268.5 274.5 294.5
39
Series ACG/ARG/AWG
Safety Instructions
These safety instructions are intended to prevent a hazardous situation and/or
equipment damage. These instructions indicate the level of potential hazard by labels of
"Caution", "Warning" or "Danger". To ensure safety, be sure to observe ISO 4414 Note 1),
JIS B 8370 Note 2) and other safety practices.

Caution : Operator error could result in injury or equipment damage.


Warning : Operator error could result in serious injury or loss of life.
Danger : In extreme conditions, there is a possible result of serious injury or loss of life.

Note 1) ISO 4414: Pneumatic fluid power--General rules relating to systems.


Note 2) JIS B 8370: General Rules for Pneumatic Equipment

Warning
1. The compatibility of the pneumatic equipment is the responsibility of the
person who designs the pneumatic system or decides its specifications.
Since the products specified here are used in various operating conditions, their compatibility for the
specific pneumatic system must be based on specifications or post analysis and/or tests to meet your
specific requirements. The expected performance and safety assurance are the responsibility of the
person who has determined the compatibility of the system. This person should continuously review
the suitability of all items specified, referring to the latest catalogue information with a view to giving
due consideration to any possibility of equipment failure when configuring a system.
2. Only trained personnel should operate pneumatically operated machinery
and equipment.
Compressed air can be dangerous if handled incorrectly. Assembly, handling or repair of pneumatic
systems should be performed by trained and experienced operators.
3. Do not service machinery/equipment or attempt to remove components until
safety is confirmed.
1. Inspection and maintenance of machinery/equipment should only be performed once measures to
prevent falling or runaway of the driven objects have been confirmed.
2. When equipment is removed, confirm that safety process as mentioned above. Turn off the supply
pressure for this equipment and exhaust all residual compressed air in the system.
3. Before machinery/equipment is restarted, take measures to prevent quick extension of a cylinder
piston rod, etc.
4. Contact SMC if the product will be used in any of the following conditions:
1. Conditions and environments beyond the given specifications, or if product is used outdoors.
2. Installation on equipment in conjunction with atomic energy, railway, air navigation, vehicles,
medical equipment, food and beverages, recreation equipment, emergency stop circuits, clutch and
brake circuits in press applications, or safety equipment.
3. An application which has the possibility of having negative effects on people, property, or animals,
requiring special safety analysis.

Back page 1
F.R.L. (Filters/Regulators/Lubricators)
Precautions 1
Be sure to read this and "Precautions for Handling Pneumatic Devices" (M-03-E3A) before using.

Design Design

Warning Caution
1. The standard bowl for the air filter, filter regulator, and lubrica- 6. Regarding specific product precautions on air filters, lubrica-
tor and the pressure gauge cover for the regulator and filter tors and mist separators, refer to the catalogue, “SMC Best
regulator, as well as the sight dome for the lubricator are ma- Pneumatics” catalogue or “Precautions for Handling Pneuma-
de of polycarbonate. Do not use in an environment where tic Devices (M-03-E3A)”.
they are exposed to or come in contact with organic solvents,
chemicals, cutting oil, synthetic oil, ester-based compressor
oil, alkali, and thread lock solutions.
Selection
2. Avoid applications where pressurized air is frequently introdu-
ced to and released from the standard bowl of an air filter, fil-
ter regulator, or lubricator. It may cause the bowl to be dama- Warning
ged. Use of a metal bowl is recommended for such applica- 1. The mineral grease used on internal sliding parts and seals
tions. may run down to outlet side components. Consult with SMC if
3. Consult with SMC if the intended application calls for absolu- this is not desirable.
tely zero leakage due to special atmospheric requirements, or 2. Regulator and filter regulator
if the use of a fluid other than air is required.
1) Residual pressure release (outlet pressure release) is not
4. Regulator and filter regulator complete even by releasing the inlet pressure. To release
Be sure to install a safety device to prevent damage or mal- residual pressure, select a model with a back flow mecha-
function of the outlet side components when the output pres- nism. Using a model without a back flow mechanism makes
sure exceeds the set pressure value. for inconsistent residual pressure release (i.e., residual
pressure may or may not be released) depending upon the
operating conditions.
Caution 2) Contact SMC if air will not be consumed in the system for a
1. Select a model that is suitable for the desired purity by refe- long period of time, or if the outlet side will be used with a
rring to the SMC’s Best Pneumatics catalogue. sealed circuit and a balanced circuit, as this may cause the
set pressure of the outlet side to fluctuate.
2. Components cannot be used for applications that are outside
the range of specifications. Consult with SMC when you anti- 3) Set the regulating pressure range for the outlet pressure of
cipate using the component outside the range of its specifica- the regulator in a range that is 85% or less of the inlet pres-
tions (such as temperature and pressure). sure. If set to above 85%, the outlet pressure will be easily
affected by fluctuations in the flow rate and inlet pressure,
3. Mist separator and micro-mist separator and become unstable.
Design the system so that the mist separator and micro-mist 4) A safety margin is calculated into the maximum regulating
separator are installed where there is less pulsation. A pres- pressure range appearing in the catalogue's specification
sure difference between internal and external pressure inside table. However, the pressure settings may exceed the num-
the element should be kept within 0.1 MPa, as exceeding this ber in the specifications.
value can cause damage.
5) Contact SMC when a circuit requires the use of a regulator
4. Regulator and filter regulator having relief sensitivity with high precision and setting accu-
Air consumption is 0.1 l/min (ANR) or less under standard racy.
specifications. Consult with SMC, if this value is not allowable. 3. Lubricator
5. Air combination 1) Contact SMC when the lubricator is used in high frequency
1) When using a 2-unit combination such as ACG0A, operations, such as in a press.
ACG0B, ACG0D, secure the top and bottom of the bra- 2) Lubrication cannot be properly performed if the operating
cket. However, when choosing the ACG20B with a down- flow rate is too low. Select a proper sized lubricator by refe-
ward facing handle, note that it cannot be fixed with bra- rring to the minimum dripping flow rate provided in this ca-
ckets in both the upper and lower side. Consult with SMC if talogue.
you need to fix the product with brackets in both the upper 3) Avoid the use of a lubricator that causes back flow as this
and lower side. may cause damage to internal parts.
2) The bracket position varies depending on the attachment 4) Use a check valve (Series AKM) to prevent the lubricant
(pressure switch) mounting. from back flowing when branching the piping on the inlet si-
3) Brackets cannot be mounted on both sides of pressure de.
switch.
4) Contact SMC for changing the bracket mounting position.

Back page 2
F.R.L. (Filters/Regulators/Lubricators)
Precautions 2
Be sure to read this and "Precautions for Handling Pneumatic Devices" (M-03-E3A) before using.

Design Adjustment

Warning Warning
4. Float-type auto-drain 1. Regulator and filter regulator
Use auto-drain under the following conditions to avoid mal- 1) Set the regulator while verifying the displayed values of the
function. inlet and outlet pressure gauges. Turning the handle exces-
<N.O. type> sively can cause damage to the internal parts.
• Operating compressor: 0.75 kW (100 l/min (ANR)) or more 2) Do not use a tool on the pressure regulator handle as this
When using 2 or more auto-drains, multiply the above value can cause damage. It must be operated manually.
by the number of auto-drains to find the capacity of the com-
pressors you will need.
For example, when using 2 auto-drains, the compressor ca-
pacity with 1.5 kW (200 l/min (ANR)) or greater is required.
Caution
• Operating pressure: 0.1 MPa or more 1. Regulator and filter regulator
<N.C. type> 1) Check the inlet pressure carefully before setting the pro-
• Operating pressure for AD17/27: 0.1 MPa or more duct.
• Operating pressure for AD37/47: 0.15 MPa or more 2) To set the pressure using the handle, turn the handle in the
direction that increases pressure and lock the handle after
the pressure is set. If this is done in the direction that de-
Mounting creases pressure, the pressure may drop from the original
set pressure. Turning the handle clockwise increases the
Caution outlet pressure, and turning it counterclockwise reduces the
pressure.
1. To avoid reversed connections of the air inlet/outlet, make 3) After setting the pressure, there may be an occurrence in
connections after confirming the “IN/OUT” mark or arrows that which the outlet pressure increases when the inlet pressure
indicate the direction of air flow. Reversed connections can is removed and then supplied again. In this case, once the
cause malfunction. air is consumed at the outlet side, the pressure becomes
2. Components with a bowl, e.g., air filter, filter regulator, lubrica- close to the original set pressure.
tor, must be installed vertically with the bowl facing down- 4) Using a product for a long period of time may fluctuate the
ward. Otherwise, faulty drain discharge and dripping cannot outlet pressure. Confirm the set pressure periodically.
be verified.
3. Ensure sufficient top, bottom, and front clearance for mainte-
nance and operation of each component. Refer to the dimen-
sions section for the minimum clearance for each component.
4. Regulator and filter regulator
1) Be sure to unlock the handle before adjusting the pressure
and to lock it after the pressure is set.
2) During transport and installation, do not apply shock to the
product, such as by dropping, doing so will affect its preci-
sion.
3) Do not install it in an area that is exposed to high tempera-
ture or humidity, because doing so will lead to improper
operation.

Back page 3
F.R.L. (Filters/Regulators/Lubricators)
Precautions 3
Be sure to read this and "Precautions for Handling Pneumatic Devices" (M-03-E3A) before using.

Piping Piping

Caution Warning
1. Before piping, it should be thoroughly blown out with air (flus- 1. Lubricator
hing) or washed to remove chips, cutting oil and other debris Try to avoid riser piping and branch lines as much as possible
from inside the pipe. on the outlet side, otherwise proper lubrication will be compro-
2. When screwing piping or fittings into ports, ensure that chips mised.
from the pipe threads or sealing material do not get inside the
piping. Also, when the pipe tape is used, leave 1.5 to 2 thread
2. Float type auto-drain
ridges exposed at the end of the threads. Drain piping should be performed under the following condi-
tions to avoid malfunction.
3. To screw piping materials into components, tighten with a re-
commended tightening torque while holding the female thread <N.O. type>
side. If the minimum tightening torque is not observed, this • Use piping whose I.D. is ø6.5 or larger, and whose length is
can cause a looseness and seal failure. On the other hand, 5 m or less. Avoid riser piping.
excess tightening torque can cause damage to the threads. <N.C. type>
Furthermore, tightening without holding the female thread si- • AD27: Use piping whose I.D. is ø2.5 or larger
de can cause damage due to the excess force that is applied AD37/47: Use piping whose I.D. is ø4 or larger
directly to the piping bracket. Length is 5 m or less. Avoid riser piping.

Recommended Tightening Torque (N⋅m)


Connection
1/8 1/4 3/8 1/2
Air Supply
thread
Torque 7 to 9 12 to 14 22 to 24 28 to 30 Caution
1. Use clean air. If chemicals, organic solvents, synthetic oil or
corrosive gases are included in the compressed air, parts
could be damaged or they can cause a malfunction.
SMC
2. When there is excessive condensate, install a device that eli-
minates water, such as a dryer or water separator (Drain
Catch) on the inlet side of the air filter.

Maintenance

Warning
1. When disassembly or installation is required during the main-
4. Avoid excessive torsional moment or bending moment other tenance, repair, or replacement of a device, be sure to follow
than those caused by the equipment’s own weight as this can the instructions provided in the instruction manual or safety
cause damage. Support external piping separately. instructions in this catalogue.
2. Perform periodical inspections to detect any cracks, scrat-
ches, or other deterioration of the transparent resin bowl of
the air filter, filter regulator, and lubricator or the sight dome of
the lubricator.
SMC
Replace with a new bowl, sight dome, or metal bowl when
any kind of deterioration is found, otherwise this can cause
damage.
3. Perform periodical inspections to detect dirt on the transpa-
rent resin bowl of the air filter, filter regulator, and lubricator or
the sight dome of the lubricator or the pressure gauge cover
of regulator and filter regulator. When you find dirt on any of
the above devices, clean with a mild household cleanser. Do
not use other cleaning agents, otherwise this can cause da-
mage.
5. Piping materials without flexibility such as steel tube piping
4. Manually open or close the drain cock of air filters, filter regu-
are prone to be affected by excess moment load and vibration
lators and lubricators. Using tools can cause the product to be
from the piping side. Use flexible tubing in between to avoid
damaged.
such an effect.
6. Be sure to provide piping for discharging the drainage becau- 5. Air filter
se there is no valve function equipped with the drain guide. 1) Replace the element every 2 years or when the pressure
Without piping, drainage or compressed air will be dischar- drop becomes 0.1 MPa, whichever comes first, to prevent
ged. Also, when performing the piping work, secure the drain damage to the element.
guide using a wrench, etc. The case can be damaged if the 2) Release accumulated condensate periodically before it rea-
drain guide is not fixed. ches the maximum capacity. Condensate that flows out to
the outlet side can cause malfunctions.
Back page 4
F.R.L. (Filters/Regulators/Lubricators)
Precautions 4
Be sure to read this and "Precautions for Handling Pneumatic Devices" (M-03-E3A) before using.

Maintenance

Warning
1. Lubricator
Use class 1 turbine oil (without additives) ISO VG32. Using ot-
her lubricant can cause damage to devices and result in mal-
functions.

Caution
1. Perform periodical inspections of the filter element and repla-
ce it as necessary. Check the element whenever the outlet
pressure drops below normal or air does not flow smoothly
during operation.
2. Regulator and filter regulator
Check the sliding part or seat of the internal valve when a set-
ting malfunction or relief leakage occur and temporary or
emergency repairs need to be made.
3. Lubricator
Check the dripping amount once a day. Drip failure can cause
damage to the components being lubricated.
4. Float type auto-drain
1) Turn the handle counterclockwise to release the drain ma-
nually. Avoid applying excessive torque to the handle, such
as by using a tool, as this can damage an auto-drain.
After releasing the condensate, turn the handle clockwise
until it stops.
2) Air leakage or other performance malfunctions can occur if
premature clogging of the element or pressure drop causes
the pressure inside the bowl to get outside the specified
pressure range parameters. Check the pressure whenever
such an irregularity occurs.

Back page 5
Series ACG/ARG/AWG
Specific Product Precautions
Be sure to read this and "Precautions for Handling Pneumatic Devices" (M-03-E3A) before using.

Procedure for replacing or changing the mounting angle of a pressure gauge

Warning
When replacing a pressure gauge and/or changing the mounting angle, release the inlet and outlet pressure completely. It is dange-
rous to replace the pressure gauge or change the mounting angle while it is under pressure.

1. Advance preparation 5. Setting the pressure gauge


Keep the handle unlocked and completely loosened. The un- After the mounting angle is adjusted as required, hold the ou-
locked condition of the handle can be visually confirmed by ter edge of the pressure gauge dial and gently press down.
the “Orange line” shown near the bottom of the handle. For reference, the required clearance between the bottom of
the dial and the top of the pressure regulator guide is shown
in table 1.
Note 1) When the pressure gauge cannot be easily positioned,
slightly rotate it. (The cog from the planet gear of the
Orange mark pressure regulator guide may be caught vertically in the
cog from the sun gear
which is mounted and

X
integrated with the
pressure gauge)
Note 2) Position the pressure
2. Removing the handle gauge to the very bot-
To remove the handle, align the  mark on the handle and tom.
the  mark on the bonnet and then pull the handle. Note 3) Attached to the tip of
the pressure gauge is
an O-ring with grease
applied to it. Please Table 1. Clearance
Orange mark use caution to prevent Dimensions
particles and/or dust
 mark from entering the pres- ARG20 ARG30 ARG40
sure gauge when it is AWG20 AWG30 AWG40
 mark set. Otherwise, they X dimension
Bonnet may cause air leaka- (reference 2.6 mm 3.3 mm 3.3 mm
value)
ge.
3. Removing the clip
When the  mark on the bonnet and the  mark on the pres- 6. Setting the clip
sure regulator guide are alligned, the clip can be seen from Insert the clip in the side of the bonnet when the  mark on
the side view of the bonnet. The clip can be picked and remo- the pressure regulator guide and the  mark on the bonnet
ved with tweezers. are aligned. When inserting and setting the clip, use an ins-
∗ When adjusting the mark, turn the pressure regulator guide trument with a narrow tip, such as tweezers.
clockwise for adjustment. Note 1) The clip is slightly tapered towards its tip to prevent it from
being released. Set the clip by slightly opening its tip.
Pressure regulator Note 2) When the clip cannot easily be set, the cause may be as
guide follows:
 mark Clip
(1) The pressure regulator screw might have been in a lower
Bonnet position than then the current one. (The pressure regula-
side view
tor screw may reach a lower position if the pressing force
of the pressure regulator screw is excessively applied.
 mark This occurs because there is a clearance between the
Bonnet pressure regulator nut and pressure spring, when the
pressure regulator screw is loosened completely.)
(2) The pressure gauge is not firmly set.
4. Removing the pressure gauge Countermeasures ..... Refer to 5 “Setting the pressure
Pull the pressure gauge out by holding the outer edge of the gauge”.
dial.
Pressure regulator
∗ Do not touch the internal mechanical portion (shown inside guide
the dotted box). Accuracy of the pressure gauge may be
adversely affected.  mark Clip
Bonnet
side view
Outer edge

 mark

Internal mechanical Bonnet


portion
7. Setting the handle
Finished when the handle is set.

Back page 6