Professional Documents
Culture Documents
Muhamad Basit Febrian
Muhamad Basit Febrian
99m
SPECTROPHOTOMETRIC DETERMINATION OF MOLYBDENUM CONTENT IN Tc
SOLUTION VIA Mo-TGA-KSCN COMPLEXES FORMATION
Muhamad Basit Febrian, Titin Sri Mulyati, Ade Suherman, Natalia Adventini, Yanuar
Setiadi, Duyeh Setiawan, Azmairit Aziz
Center for Applied Nuclear Science and Technology, National Nuclear Energy Agency,
Jalan Tamansari 71 Kota Bandung 40132
Email : mbasitf@batan.go.id
Diterima: 16-02-2018
Diterima dalam bentuk revisi: 05-04-2018
Disetujui: 02-08-2018
ABSTRACT
ABSTRAK
71
Jurnal Sains dan Teknologi Nuklir Indonesia ISSN 1411 – 3481
Indonesian Journal of Nuclear Science and Technology EISSN 2503 - 1287
Vol. 19, No.2, Agustus 2018: 71-80
72
Spectrophotometric Determination of Molybdenum Content in 99mTc ISSN 1411 - 3481
Solution via Mo-TGA-KSCN Complexes Formation EISSN 2503 - 1287
(Muhamad Basit Febrian)
TGA could act as masking agent to with indigenous DC variable power supply
iron by prevent Fe-SCN complexes with voltage range 10 – 500 Volt with current
formation which could interfere Mo-SCN limiter at 25 Ampere. Principally,
complexes absorbance (7). –SH group in electrophoresis procedure of 99Mo was
TGA acts as both reducing agent and same with other radioisotopes
electron donor for complexes formation. – electrophoresis procedure stated in previous
OH group in acetic acid side acts as electron study [7].
for complexes formation, as the result, TGA Single channel analyzer with NaI(Tl)
works as reducing and chelating agent detector was used for electrophoresis paper
(Figure 1). counting process. Each electrophoresis
Reduction of molybdenum by TGA paper to be counted were cut per 1 cm and
could be controlled between Mo(V) and inserted into counting chamber. Time for
Mo(IV) with Mo(V) as most stable reduction each counting was 4 seconds.
product between both reduction product. By
Molybdenum Complexes Formation
TGA, over reduction of Mo(VI) to lower
200 uL of 1000 ppm Mo stock solution
oxidation number could be avoided (5).
was added into 10 mL flask. 25% HCl was
In order to find optimum condition of
added into Mo solution prior to thioglycolic
Mo-SCN complexes formation for analysis
acid (TGA) addition. KSCN was added then
purpose, this paper would describe
orange complexes solution was formed. H2O
optimization study of Mo(VI) reduction and
was added until 10 mL. Volume of HCl, TGA
Mo-SCN complexes formation.
and KSCN were determined in reagent
Spectrophotometric determination of
optimization.
99m
molybdenum content in Tc solution
sample would be carried out by the
Optimization Studies
optimized reagent composition and condition.
Thioglicolic Acid works as reducing
agent in acid condition. To determine the
effect of acid added, the series of 4N HCl,
2. MATERIAL AND METHODS
HNO3 and 2N H2SO4 was added into 10 mL
Apparatus
flask contain 20 ppm Mo, then 200 uL of
Hitatchi 12-120 double beam UV-
10% TGA was added followed by 1000 uL
Visible Spectrophotometer with tungsten
addition of 10% KSCN. Effect of acidity level
and deuterium lamp, range 190 nm – 370
was investigated by adding various volume
nm (UV) 370 nm – 820 nm (visible).
of optimized acid.
Resolution of wavelength selector is 0.1 nm.
To determine optimum quantity of
Electrophoresis chamber made from
thioglycolic acid and KSCN addition,
polyethylene with electrolyte capacity up to
optimization was carried out by varying
2000 mL. Length of electrophoresis paper is
volume of TGA and KSCN. 50, 100, 200,
14 cm for each pole direction. This
300 and 400 µL of 10% TGA was added into
electrophoresis chamber was connected
5 volumetric flasks, each flask contain 20
73
Jurnal Sains dan Teknologi Nuklir Indonesia ISSN 1411 – 3481
Indonesian Journal of Nuclear Science and Technology EISSN 2503 - 1287
Vol. 19, No.2, Agustus 2018: 71-80
ppm Mo and HCl. 0, 250, 500, 750, 1000, 3. RESULT AND DISCUSSION
1500 and`1700 µL of 10% KSCN was added
Molybdenum Complexes Formation
into 7 volumetric flasks, each flask contain 99m
The quality control process of Tc
20 ppm Mo, volume of optimized HCl and
produced in TRIGA Bandung Research
volume of optimized TGA. Finally, aquadest
Reactor consists of some quality test in
was added until 10 mL mark.
radiochemical purity, radionuclidic purity,
All of samples and blanks were
radioactive 99Mo content and non radioactive
measured in Hitachi double UV-Vis
molybdenum content. Previously, semi-
Spectrophotometer using identical quartz
quantitative non radioactive molybdenum
glass cuvette.
content was employed by spot test using
99m
Tc Samples Solution thiocyanante method. Previous reducing
Proses 99m
TcO4- sample solution was agent in thiocyanate method was stannous
irradiated 99
Mo was dissolved in 20 mL 5N radioisotope solution, spectrophotometric
and then shaken using automatic shaker for Thioglycolic acid was studied both as
10 minutes under lead gloves box reducing agent or complexing agent for
protection. MEK phase was separated from some metals (9). Complexes of Mo-TGA
aqueous phase using separatory funnel. gave yellow colored with absorbance at 370
99m
MEK phase containing Tc was dried in nm when the blank has no significant
water bath for 10 minutes. Finally 2 mL of absorbance (Figure 2). This result was in
0,9% NaCl was added into dried MEK. accordance with other result (10).
Procedure of electrodeposition method for Absorbance of the Mo-TGA complexes was
separation of 99mTc from 99Mo was described depended on the pH of the solution. In the
in previous study (8).
74
Spectrophotometric Determination of Molybdenum Content in 99mTc ISSN 1411 - 3481
Solution via Mo-TGA-KSCN Complexes Formation EISSN 2503 - 1287
(Muhamad Basit Febrian)
75
Jurnal Sains dan Teknologi Nuklir Indonesia ISSN 1411 – 3481
Indonesian Journal of Nuclear Science and Technology EISSN 2503 - 1287
Vol. 19, No.2, Agustus 2018: 71-80
Mo(V)2O3(TGA)44- Mo(V)2O3(HTGA)4- ….
(eq 3)
76
Spectrophotometric Determination of Molybdenum Content in 99mTc ISSN 1411 - 3481
Solution via Mo-TGA-KSCN Complexes Formation EISSN 2503 - 1287
(Muhamad Basit Febrian)
Amount of HCl added has the effect in Addition of 0.2 mL to 0.3 mL of 10%
the formation of Mo-SCN complexes. The thioglycolic acid into 20 ppm Mo solution
optimum condition was the addition of 3 mL, provide stable absorbance for 20 ppm Mo
4mL and 5 mL 25% HCl, 20 ppm Mo which solution as Mo-SCN complexes. Addition
gave the absorbance value 2.09±0.032, more TGA than optimum volume became
2.08±0.030 and 2.08±0.025 respectively less effective because no significant
(Figure 7), but too much addition of HCl increase for the absorbance (Figure 8). In
decreased the absorbance of Mo(V)SCN5 complexation with SCN-, addition of of 1 mL
complex according to the Fig 7 with the of 10% KSCN was sufficient enough initiate
addition of 6 mL HCl 25%. Thus, the Mo-SCN complexes formation with more
formation of Mo(V)SCN complexes favors KSCN addition seems to be less effective
high acidity than mild-acidity. Like the (Figure 9). Thus, it can be concluded that
oxidation effect in other metal (12), the addition of 0.2 mL 10% TGA and 1 mL 10%
addition of oxidating acid like HNO3 and KSCN was selected in determination of Mo
H2SO4 is not recommended because it via Mo-SCN complexes
would re-oxidize the Mo(V) to Mo(VI) and
absorbance value would decreased as low
as blank.
Optimization Study
77
Jurnal Sains dan Teknologi Nuklir Indonesia ISSN 1411 – 3481
Indonesian Journal of Nuclear Science and Technology EISSN 2503 - 1287
Vol. 19, No.2, Agustus 2018: 71-80
78
Spectrophotometric Determination of Molybdenum Content in 99mTc ISSN 1411 - 3481
Solution via Mo-TGA-KSCN Complexes Formation EISSN 2503 - 1287
(Muhamad Basit Febrian)
Table 3. Measurement of 99mTc Sample from 3. Up to 5 mL sample can be added into the
Electrodeposition and Extraction Methods, (a) flask
99Mo determined by Gamma Spectrometry (b)
determined by UV-Vis Spectrophotometry 4. Reagent addition must be carried out in
sequence : added 3 mL 25% HCl first
Impurities
Non followed by 200 µL of 10% TGA and 1 mL of
Sample 99Moa radioactive 10% KSCN for the last
Molybdenumb
was good with r = 0.9988 ± 0.0007 from 2 PSTNT BATAN Research Budget for fiscal
ppm Mo to 30 ppm Mo. Limit detection of the year 2017. The authors would like to
method was 0.212 ppm. Interference did not express their gratitude to TRIGA Reactor
distort the measurement when MEK, oxalic Division and Labeled Compound and
the future to confirm the traceability of the Isabela as 99mTc extraction expert. .
79
Jurnal Sains dan Teknologi Nuklir Indonesia ISSN 1411 – 3481
Indonesian Journal of Nuclear Science and Technology EISSN 2503 - 1287
Vol. 19, No.2, Agustus 2018: 71-80
80