Professional Documents
Culture Documents
Contents
1 Library Information
1.1 Version Mapping
1.2 Documentation Overview
1.3 Documentation Conventions
1.4 Documentation Development
1.5 Where to Obtain Documentation
1.6 How to Provide Documentation Feedback
1.7 Technical Support
1.8 Searching Multiple Document Packages
1.9 Library Changes
1.9.1 Product Version (V100R005C10)_Doc Version 01 (2017-09-20)
1.9.2 Product Version (V100R005C00)_Doc Version 01 (2017-04-10)
1.9.3 Product Version (V100R003C10)_Doc Version 03 (2017-08-15)
1.9.4 Product Version (V100R003C10)_Doc Version 02DP01 (2017-01-15)
1.9.5 Product Version (V100R003C10)_Doc Version 01 (2016-07-01)
1.9.6 Product Version (V100R003C00)_Doc Version 02DP01 (2016-12-25)
1.9.7 Product Version (V100R003C00)_Doc Version 01 (2015-12-31)
1.9.8 Product Version (V100R002C10)_Doc Version 04 (2017-06-30)
1.9.9 Product Version (V100R002C10)_Doc Version 03DP01 (2016-12-05)
1.9.10 Product Version (V100R002C10)_Doc Version 02 (2015-10-25)
1.9.11 Product Version (V100R002C10&V100R002C00SPC810)_Doc Version 01
(2015-05-30)
1.9.12 Product Version (V100R001C30)_Doc Version 03 (2014-12-31)
1.9.13 Product Version (V100R001C30)_Doc Version 02 (2014-08-31)
1.9.14 Product Version (V100R001C30)_Doc Version 01 (2014-06-30)
1.9.15 Product Version (V100R001C20)_Doc Version 01 (2014-04-30)
1.9.16 Product Version (V100R001C01)_Doc Version 03 (2013-11-30)
1.9.17 Product Version (V100R001C01)_Doc Version 02 (2013-09-10)
1.9.18 Product Version (V100R001C01)_Doc Version 01 (2013-08-10)
1.9.19 Product Version (V100R001C00)_Doc Version 03 (2014-02-28)
1.9.20 Product Version (V100R001C00)_Doc Version 02 (2013-07-10)
1.9.21 Product Version (V100R001C00)_Doc Version 01 (2013-01-31)
1.10 Version Updates
1.10.1 Feature
1.10.2 Hardware
1.10.3 Alarm
1.10.4 Performance Event
1.11 Multimedia Collection
6.8.1 Signal Flow
| OSN 9800 V100R005C10 Operating and Maintaining Your
Network[For 2nd Line Engineer]
Date: 2017-09-20 | Product Version: 01
What's New
Planning Engineer
Deployment Engineer
Field Engineer
Quick Links
Bookshelf
Getting Started
WDM Basics
App
Tools
Info-Finder
WDM/OTN Hardware Configuration Assistant
WDM Calculation Assistant
Resources
Video
Poster
Infographic
Datasheet
Gallery
Contact Us
LinkedIn
GroupSpace
Email
NOTE:
Only OptiX OSN 9800 universal platform subrack supports Web LCT.
Product Documentation
Product documents are delivered with products to customers. With these documents,
customers can more easily understand, operate, and maintain Huawei products.
Online Help
The online help is integrated into the operation and maintenance interfaces. It
provides descriptions of the interfaces and related tasks for operation and
maintenance. It is released with the software.
The relationship between product documentation and the online help is as follows:
The focus of the online help is on GUI elements, such as menus, buttons, and
parameters, and operations, while the focus of the product documentation is on
equipment operations and maintenance scenarios.
The product documentation and online help describes tasks pertaining to operation
and maintenance.
Release Documentation
The release documentation is released when the software is upgraded.
Symbol Description
General Conventions
The general conventions that may be found in this document are defined as follows.
Convention Description
GUI Conventions
The GUI conventions that may be found in this document are defined as follows.
Convention Description
Development Process
The Huawei Information Development Department writes the product documentation.
The documentation development consists of the following phases:
1. Analyze the customer requirements.
2. Write a documentation development plan.
3. List the documentation deliverables by document name.
4. Update the documents impacted by the product release.
5. Test and verify the documentation deliverables impacted by the product release.
6. Release the documents.
The quality of the documentation is guaranteed by implementing tasks at different
phases and conducting a document review at the last phase.
Standards Compliance
The documentation development process is compliant with the TL9000 standards of
the Quality Excellence for Suppliers of Telecommunications Forum
Product Documentation
describes different methods of obtaining a document in the product
Table 1
documentation.
Table 1 Methods of obtaining a document
Stage Method
NOTE:
When logging in to the support Web site, apply for a username and a password of "equipment user"
authority by using your company e-mail address. For support, contact Huawei technical support
engineers.
Online Help
The Online Help release is integrated into the software package. Display the Online
Help by one of the following methods:
Choose Help from the Main Menu on the NMS.
Press F1 after starting the NMS.
Release Documentation
A release document is delivered with the product software package. Contact your
local Huawei office to obtain a release document.
Parent topic: Library Information
Security
Client Service Encryption: The product function is enhanced. For more information, see Featu
Management
Monitoring Browsing the Performance Monitoring Management Function of Ethernet RMON (NE-Level) is added.
Alarm and
Performance Enabling the Performance Monitoring Management Function of Ethernet RMON (NE-Level) is added.
Clearing
Alarms Add ARP_FAIL.
Add BD_FILE_NOT_ACTIVE.
Add BRDCASTRATIO_OVER.
Add CHAN_PWR_HIGH.
Add LANE_IN_PWR_HIGH.
Add LANE_IN_PWR_LOW .
Add LANE_LOS.
Add LANE_OUT_PWR_HIGH.
Add LANE_OUT_PWR_LOW .
Add MAC_FCS_NUM_SD.
Add MAC_FCS_NUM_EXC.
Add NEIP_CONFUSION.
Add PATCH_INIT_FAIL.
Add PATCH_OP_TIMEOUT.
Add SUBCARD_COM_FAIL.
Add SUBCARD_MISMATCH.
Add SUBCARD_OFFLINE.
Add SUBCARD_TEMP_OVER.
Add SUBCARD_UPGRADE_FAIL.
Delete MASTER_SLAVE_MISMATCH.
General
Operation Collecting the Self-Learning MAC Address is added.
Guide
Configuring
Services and Adjusting Service Timeslots is added.
Features
Configuring an LDC Board (by Trail) is added.
Configuring
Packet Configuring Packet Services on an EoO Board in E2E Mode is added.
Services on
EoO Boards
Update Description
Configuring
Automatic ALS: The product function is enhanced. For more information, see Feature Updates.
Optical
Power ALC: The product function is enhanced. For more information, see Feature Updates.
Management
APE: The product function is enhanced. For more information, see Feature Updates.
IPA: The product function is enhanced. For more information, see Feature Updates.
IPA of Raman System: The product function is enhanced. For more information, see Featu
U64/U32/U16
Boards These boards are updated. You can click a board to view details about it.
Added the support for the extended C-band on the TNU1G402/TNU1G404/TNX5L4
Added the support for Client Service Encryption on the TNY3C404 and TNX1G404 boar
Added the support for ODUk loopback on the board.
Added the support for idle code on the
TNY1C130/TNY1C216/TNY2C220/TNY2C210/TNY3C230/TNY3C210/TNY3C220/TNY
02S board.
Universal
Platform These boards are newly supported. You can click a board to view details about it.
Subrack
Board TN52DAP
Description TN52DAPXF
TN11LDC
TN51DWSS20
These boards are updated. You can click a board to view details about it.
Added the support for the extended C-band on the TN11ITL06/TN12RDU9/TN13OL
Added the support for idle code on the TN18LSC/TN11LOA/TN14LSX board.
Board Alarm
List Add DWSS20 Board Alarm List.
Add DAP Board Alarm List.
Add DAPXF Board Alarm List.
Add LDC Board Alarm List.
Modified CTU Board Alarm List.
Modified E124S Board Alarm List.
Modified E208S Board Alarm List.
Modified E212S Board Alarm List.
Modified E302S Board Alarm List.
Modified E401S Board Alarm List.
Modified EC116S/EC404S Board Alarm List.
Update Description
Update Description
U64/U32/U16 Board
Description
These boards are newly supported. You can click a
board to view details about it.
TNV3T401
TNV3T402
TNU4U402
TNU4U401
TNV1E124/TNV1E208/TNV1E212/TNV1E302/TNV1E401 boards.
Added the support for the packet service protection
against multiple fiber cuts on the U210, U401 boards.
Added the support for Client Service Encryption on
the V3T230/V3T220/V3T210 board.
Added the support for 2.125 Gbit/s Multirate-0.5
km-eSFP optical module on the TNV1E124 board.
Added the support for 10 Gbit/s Single-Rate-0.3 km-
XFP optical module on the TNV1E208/TNV1E212 board.
Added the support for 100GBASE-SR10-100m-CFP
optical module on the TNV1E401 board.
The TN17LSC board supports the regeneration mode.
The TNV1S216 board supports AU-3 services, converts
three AU-3 signals into one AU-4 signal, and
performs lower-order grooming on VC-3/VC-12
signals.
Configuring Services and
Features The chapter of Configuring a Port-Level M:N Protection is added.
Configuring Packet Services
and Service Protection The chapter of Packet Service Protection Against Multiple Fiber
Cuts is added.
Update Description
Add WAVELEN_REPEATED.
Board Alarm List
Add U402 Board Alarm List.
Modified CTU Board Alarm List.
Modified FIU Board Alarm List.
Modified G402 Board Alarm List.
Modified G404 Board Alarm List.
Modified LDX Board Alarm List.
Modified LOA Board Alarm List.
Modified LOG Board Alarm List.
Modified LOM Board Alarm List.
Modified LSX Board Alarm List.
Modified N401 Board Alarm List.
Modified N402 Board Alarm List.
Modified N404 Board Alarm List.
Modified SCC Board Alarm List.
Modified ST2 Board Alarm List.
Modified T210 Board Alarm List.
Modified T220 Board Alarm List.
Modified T230 Board Alarm List.
Modified T401 Board Alarm List.
Modified T402 Board Alarm List.
Modified U401 Board Alarm List.
Modified UXCS Board Alarm List.
Modified WMU Board Alarm List.
Board Performance Event List
Add U402 Board Performance Event List.
Modified T401 Board Performance Event List.
Modified T402 Board Performance Event List.
Modified U401 Board Performance Event List.
Monitoring
Update Description
Configuring Automatic Optical Power IPA: The product function is enhanced. For
Management
more information, see Feature Updates.
IPA of Raman System: The product function is
enhanced. For more information, see Feature
Updates.
Configuring Clock
Configuring physical clock (U64/U32/U16
Subrack): Updated Configuring Clock Attributes.
Clearing Alarms
BUS_ERROR: Modified alarm parameters.
HARD_ERR: Added alarm parameters, causes,
and handling procedures for abnormal
signal flows received on cross-connect
boards.
NO_ELABEL: Added alarm parameters, causes,
and handling procedures when the patch
package of the system control board does
not take effect.
Board Alarm List
Added AST2 Board Alarm List.
Board Performance Event List
Added AST2 Board Performance Event List.
Update Description
Technology Reference
Outband DCN: Updated Related Concepts and
Networking Capability.
Update Description
Update Description
Packet Application
Added EoO Application in an OTN.
U64/U32/U16 Board
Description
These boards are newly supported. You can click a
board to view details about it.
TNV2T220E
TNV2N220
TNU2N402PT51
TNU3N402T50
TNU3N401T50
TNU3U401T50
Update Description
U64/U32/U16 These boards are newly supported. You can click a board to
Board Description
view details about it.
TNV2EFI
TNS2EFI
TNV3T210\TNV3T220\TNV3T230.
TNV3T404.
TNU5N402
TNU5N404
TNU1G402/TNU1G404.
TNV1SXCL.
These boards are updated. You can click a board to view details
about it.
N401:
TNU3U401T51/TNU3U401T58/TNU3U401T61/TNU3U401T68
added the support for PMD Threshold(ps) parameter.
TNV1E124/TNV1E208/TNV1E212/TNV1E302/TNV1E401: Added the
support for LPT function and port mirroring function.
Universal Platform
Subrack Board These boards are newly supported. You can click a board to
Description
view details about it.
TN18LSC/TN17LSCT62
TN17LTXT62
TN58NS4T62
TN51MCS0816
TN97ERPC
TN11AST2
These boards are updated. You can click a board to view details
about it.
TN11LOA: Added the support for the ISC 1G, ISC 2G services
on the board.
TN17LSC: The TN17LSCT51/TN17LSCT61 board newly support
for PMD Threshold(ps) parameter.
TN17LTX: Added the support for InfiniBand 5G service.
TN58NS4:
TN58NS4T51/TN58NS4T58/TN58NS4T61/TN58NS4T68
board newly support for PMD Threshold(ps) parameter.
TN13ST2: The TN13ST2 board newly supports the ITU-T
G.8275.1 protocol.
STG: The board newly support the ITU-T G.8275.1 protocol.
Configuring
Services and ODUk SNCP: The product function is enhanced. For more
Features
information, see Feature Updates.
Tributary SNCP: The product function is enhanced. For more
information, see Feature Updates.
Configuring SDH
Services and SNCP: The product function is enhanced. For more
Service Protection
information, see Feature Updates.
Configuring CES
Services and
Added Configuring CES Services in E2E Mode.
Service Protection
Update Description
Configuring Packet
Services and
Added Configuring LPT.
Service Protection
Configuring
Automatic Optical IPA: The product function is enhanced. For more information,
Power
Management seeFeature Updates.
IPA of Raman System: The product function is enhanced. For
more information, seeFeature Updates.
Configuring Clock
The chapter of Configuring ITU-T G.8275.1 Clocks is added.
Technology
Reference Outband DCN: The product function is enhanced. For more
information, see Feature Updates.
Beyond 100G Transmission System: The product function is
enhanced and information optimization. For more
information, see Feature Updates.
100G and 40G Coherent Transmission Systems : The product function is
enhanced. For more information, see Feature Updates.
The chapter of ITU-T G.8275.1 is added.
Using the OD
System for
The product function is enhanced. For more information, see
Network Feature Updates.
Monitoring and
Maintenance
Using the FD
System for Fiber
The product function is enhanced. For more information, see
Quality Monitoring Feature Updates.
Clearing Alarms
Added B3_EXC_VC3.
Added B3_SD_VC3.
Added BIOS_STATUS.
Added FC_AIS.
Added HP_LOM.
Added LASER_TYPE_MISMATCH.
Added LASER_PARA_ERR.
Added LP_RDI_VC3.
Added LP_REI_VC3.
Added LP_SLM_VC3.
Added LP_TIM_VC3.
Update Description
Added LP_UNEQ_VC3.
Added LSR_KEY_UNLOCK.
Added MCS_SWITCH_BLOCKED.
Added MPN_APS_INDI.
Added MPN_OPPOSITE_CFG_ERR.
Added MPN_APS_STOP.
Added ODC_DOOR_OPEN.
Added ODU_READY_TO_REVERT.
Added ODU_SNCP_WEAK.
Added OPU4_LOOMFI.
Added ORP_CRITICAL_HI.
Added OSC_CLK_MISMATCH.
Added RACK_CONFLICT_SCREEN.
Added SCC_CHANGE.
Added TU_LOP_VC3.
Added TU_AIS_VC3.
Added XCP_DEGRADE.
Handling
Performance Added FSWIOP.
Events
Added FSWOOP.
Added FSWSNL.
Added FSWSNR.
Added PEAK_INPOWER.
Added PEAK_LSBIAS.
Added PEAK_LSTMP.
Added PEAK_OUTPOWER.
Added VALLEY_INPOWER.
Added VALLEY_LSBIAS.
Added VALLEY_LSTMP.
Added VALLEY_OUTPOWER.
Board Alarm List
Added AST2 Board Alarm List.
Update Description
Update Description
Update Description
Update Description
Added DGD.
Added RSOOF.
Configuring OTN ASON Networks
Creating an Electrical-Layer Diamond WDM ASON ODUk Trail:
TNV1S216.
TN98N401.
TN98N402.
Universal Platform Subrack Board
Description These boards are newly supported by
V100R03C00. You can click a board to view details
about it.
TN58NS4T31.
TN15TM20.
TN51HBA.
TN12RAU106E.
TN12RAU201E.
TN13STG.
TN97D48.
TN97FIU.
TN97M48V.
TN97MD2.
Update Description
TN97ITL.
.TN97TD20
.TN97TM20
.TN96WSD9
.TN96WSM9
TN97ASE.
TN97OAU2.
TN97OBU2.
TN97RPC.
TN51RPC.
TN51ROP.
TN11OLSP.
TN11OLSPA/TN11OLSPB.
Configuring Services and Features
Optical Line Protection: The product function is
enhanced. For more information, see Feature
Updates.
Configuring Automatic Optical
Power Management APE: The product function is enhanced. For
more information, see Feature Updates.
IPA: The product function is enhanced. For more
information, see Feature Updates.
IPA of Raman System: The product function is
enhanced. For more information, see Feature
Updates.
Configuring SDH Services and
Service Protection Configuration Examples in E2E mode is added.
Configuration Examples in single NE mode is added.
Using the OD System for Network
Monitoring and Maintenance
The product function is enhanced. For more
information, see Feature Updates.
Using the FD System for Fiber
Quality Monitoring
The product function is enhanced. For more
information, see Feature Updates.
Board Alarm List
Added ASE Board Alarm List.
Update Description
Update Description
U64/U32/U16 Board
Description
This board is newly supported. You can click a board
to view details about it.
Update Description
TN11AST2
Using the FD System for Fiber
Quality Monitoring
The product function is enhanced. For more
information, see Feature Updates.
Clearing Alarms
BUS_ERROR: Modified alarm parameters.
HARD_ERR: Added alarm parameters, causes, and
handling procedures for abnormal signal flows
received on cross-connect boards.
NO_ELABEL: Added alarm parameters, causes, and
handling procedures when the patch package of
the system control board does not take effect.
Board Alarm List
Added AST2 Board Alarm List.
Board Performance Event List
Added AST2 Board Performance Event List.
Configuring Services and
Features Configuring Optical Line Protection: The product function is
enhanced. For more information, see Feature Updates.
Configuring Automatic Optical
Power Management IPA: The product function is enhanced. For more
information, see Feature Updates.
IPA of Raman System: The product function is enhanced.
For more information, see Feature Updates.
Technology Reference
Outband DCN: The product function is enhanced. For
more information, see Feature Updates.
Update Description
Update Description
Update Description
U64/U32/U16 Board
Description
These boards are newly supported. You can click a
board to view details about it.
TNU5N402
TNV1SXCL
TNU2N402P
TNU1N402P
TNV2N220
TNV1S216
TNV3T404
Update Description
TNU5N404
TNV3T210\TNV3T220\TNV3T230
Maintenance
Using the FD System The product function is enhanced. For more
for Fiber Quality information, see Feature Updates.
Monitoring
Technology Reference
Beyond 100G Transmission System: The product function is
enhanced. For more information, see Feature Updates.
100G and 40G Coherent Transmission Systems : The product
function is enhanced. For more information, see
Feature Updates.
Clearing Alarms
Added B3_EXC_VC3.
Added B3_SD_VC3.
Added LASER_TYPE_MISMATCH.
Added LASER_PARA_ERR.
Added LP_RDI_VC3.
Added LP_REI_VC3.
Added LP_SLM_VC3.
Added LP_TIM_VC3.
Added LP_UNEQ_VC3.
Added LSR_KEY_UNLOCK.
Added ODU_SNCP_WEAK.
Added ODUCN_PM_LCK.
Added POWER_SAMPLE_DIFF.
Added RACK_CONFLICT_SCREEN.
Added TU_LOP_VC3.
Added TU_AIS_VC3.
Added XCP_DEGRADE.
Handling Performance Events
Added FSWIOP.
Added FSWOOP.
Added FSWSNL.
Added FSWSNR.
Added PEAK_INPOWER.
Update Description
Added PEAK_LSBIAS.
Added PEAK_LSTMP.
Added PEAK_OUTPOWER.
Added VALLEY_INPOWER.
Added VALLEY_LSBIAS.
Added VALLEY_LSTMP.
Added VALLEY_OUTPOWER.
Board Alarm List
Added T230 Board Alarm List.
Added N220 Board Alarm List.
Added N402P Board Alarm List.
Added S216 Board Alarm List.
Added SXCL Board Alarm List.
Added OLSP/OLSPA/OLSPB Board Alarm List.
Added ROP Board Alarm List.
Modified EFI Board Alarm List.
Modified HBA Board Alarm List.
Modified N402 Board Alarm List.
Modified N404 Board Alarm List.
Modified RAU1 Board Alarm List.
Modified RAU2 Board Alarm List.
Modified RPC Board Alarm List.
Modified STG Board Alarm List.
Modified T210 Board Alarm List.
Modified T220 Board Alarm List.
Modified T404 Board Alarm List.
Modified TM20 Board Alarm List.
Board Performance Event List
Added T230 Board Performance Event List.
Added N220 Board Performance Event List.
Added N402P Board Performance Event List.
Added S216 Board Performance Event List.
Update Description
TN11CMR2
TN11MR2
TN11MR4
TN11MR8
TN12MR8V
TN11SBM2
Update Description
TNV2XCS
Added CPW_OCH_SER_SLADEG.
Added CPW_OCH_SER_SYNFAIL.
Added CPW_OCH_SER_WL_OVER.
Added CPW_OCH_SRV_INT_OUT.
Added CPW_ODU_SER_INT.
Added CPW_ODU_SER_NOTOR.
Added CPW_ODU_SER_ORSNCP.
Added CPW_ODU_SER_ORSNCP.
Added CPW_ODU_SER_PRERTF.
Added CPW_ODU_SER_PRTFAIL.
Added CPW_ODU_SER_RRTLOCK.
Added CPW_ODU_SER_SLADEG.
Added CPW_ODU_SER_SYNFAIL.
Added CPW_ODU_SPD_ADJ_MIS.
Added CPW_ODU_SRV_INT_OUT.
Added CPW_ODU_TEL_DEG.
Added CPW_ODU_TEL_DOWN.
Added CPW_ODU_TEL_MAINTAIN.
Added CPW_ODU_TEL_PATHMIS.
Added CPW_OMS_SEGMENT_DEG.
Added CPW_OMS_TEL_DEG.
Added CPW_OMS_TEL_DOWN.
Added CPW_OMS_TEL_EXHAUST.
Added CPW_OMS_TEL_MAINTAIN.
Added CPW_OMS_TEL_OCHMIS.
Added CPW_OMS_TEL_PATHMIS.
Added CPW_OTU_BW_MIS.
Added CPW_OTU_TEL_DEG.
Added CPW_OTU_TEL_DOWN.
Added CPW_OTU_TEL_MAINTAIN.
Update Description
Added CPW_OTU_TEL_MM.
Added CPW_OTU_TEL_PATHMIS.
Added CPW_SER_XC_EXCEPT.
Added ELAN_AUTO_LOOP.
Added ELAN_LDT_IF_BLOCKED.
Added ELAN_SMAC_FLAPPING.
Added ENV_TEMP_OVER.
Added HP_CROSSTR.
Added MEM_OVER.
Added OCH_READY_TO_REVERT.
Added PTP_ATTR_MISMATCH.
Added PTP_OFFSETSUM_OVER.
Added PTPSRC_CLKCLS_DEC.
Added RXCFG_WAVEDATA_MIS.
Added STD_PTP_OFFSET_OVER.
Troubleshooting
Added Handling ASON Network Failures.
Replacing Boards and Components
Precautions: Added the TDM board.
In the following topics, updated the substitution
relationship.
Optical Transponder Board: Added the TN17LTX,
TN17LSC board.
Optical Multiplexer and Demultiplexer Board: Added the
TN16FIU board.
Optical Supervisory Channel Board: Added the
TN12ST2/TN13ST2 board.
Replacing the Cross-Connect Board: Added the
substitution relationship for the cross-connect
board.
Board Alarm List
Added DWSS20 Board Alarm List.
Added N401P Board Alarm List.
Update Description
Technology Reference
Outband DCN: The product function is
enhanced. For more information, see Feature
Updates.
Update Description
Quick View of Product Supported Services Types: Added the EC116, EC404,
G210, G220, LOG and TMX boards.
Packet Application: Added CES/CEP Services.
Clearing Alarms
Added TDM alarms.
Added BIP_EXC.
Added BIP_SD.
Added FORCED_INSERT_AIS.
Added MC_LMS_CFG_MISMATCH.
Added ODUCN_PM_AIS.
Added ODUCN_PM_BDI.
Added ODUCN_PM_DEG.
Added ODUCN_PM_SSF.
Added ODUCN_PM_TIM.
Added OPUCN_MSIM.
Added OPUCN_PLM.
Added OTUCN_BDI.
Added OTUCN_DEG.
Added OTUCN_LOF.
Added OTUCN_LOM.
Added OTUCN_SSF.
Added OTUCN_TIM.
Added PWD_ENCRYPT_RISK.
Handling Performance Events
Added performance event list of bit errors in
higher order paths and lower order paths.
Added performance event of pointer
justifications.
Added performance events of the packet
service.
Update Description
T210
TNV2G210/TNV2G220
TNU2U401T65
TNV1EC116/TNV1EC404
Universal Platform Subrack Board
Description These boards are newly supported by
V100R001C30SPC200. You can click a board to
view details about it.
TN12LOG
TN12TMX
Universal Platform Subrack AC
Power Supply
The UPS subrack newly supports AC power supply.
Each AC power cable is directly connected to the
external AC power supply and APIU.
Update Description
Update Description
Updates.
Update Description
the product.
Service mapping on boards: Described the service
mapping process for data boards.
Added Packet Application.
Network Management Intra-NE Communication Management Based on Master-Slave
Subrack Configuration: Deleted the related description of
U32/U64 master-slave subrack.
Planning Guidelines (Packet)
Added the whole chapter.
Packet Specifications
Added the whole chapter.
Clearing Alarms
Added packet alarms.
Added ALM_ALS
Added CFG_DATASAVE_FAIL
Added CFG_DATACHECK_FAIL
Added IN_PWR_ABN
Added LASER_MOD_ERR
Added LASER_OPEN_FAIL
Added LSR_BCM_ALM
Added LSR_NO_FITED
Added OUT_PWR_ABN
Added POWER_ABNORMAL
Added RMT_DEV_DYING_GASP
Added TEMP_HEAT
Added W_OFFLINE
Modified TIME_LOCK_FAIL
Product Performance Event List
Updated Performance Events of the RMON Function
Troubleshooting
Added Packet Service Problems.
Replacing Boards and
Components General Guide for Replacing a Board: Added packet
service boards.
Impact on the System: Added impact on the system of
the packet board.
Configuring Services and
Features Client 1+1 Protection: The product function is
Update Description
TNV2N401/TNU2N401
TNV2N402/TNU2N402
TNV2XCS
TNV2T220
Universal Platform Subrack Board
Description
These boards are newly supported by
V100R001C20. You can click a board to view
details about it.
TN15LSC
TN57NS4
TN11ITL06
TN16WSD9
TN16WSM9
TN13WSMD4
TN12WSMD9/TN15WSMD9
TN12HSC1
TN12STG
Quick View of Product
ROADM Application: Flexible ROADM Application is added.
Configuring Services and Features
Client 1+1 Protection: The product function is
enhanced. For more information, see Feature
Updates
Updates.
Added SSM_LOS
Added SSM_QL_FAILED
Added SYN_BAD
Added SYNC_C_LOS
Added SYNC_F_M_SWITCH
Added SYNC_LOCKOFF
Added SWDL_BD_MATCH_FAIL
Added TIME_LOCK_FAIL
Added TIME_LOS
Added TIME_NO_TRACE_MODE
Handling Performance Events
Added FREQDEV
Added MEANPATHDELAY
Added PHASEOFFSET
Common Fault Isolation Methods
Test Frame: Added the TN15LSC board that support
the test frame.
Replacing Boards and Components
General Guide for Replacing a Board: In the following
topics, updated the substitution relationship.
Optical Transponder Board: Added the TN15LSC
board.
Regeneration Board: Added the TN57NS4 board.
Reconfigurable Optical Add and Drop Multiplexing Board:
Update Description
Added LAG_MEMBER_DOWN
Added LASER_SHUT
Added MAC_FCS_EXC
Added MPLS_PW_AIS
Added MPLS_PW_LOCV
Added MPLS_PW_OAMFAIL
Added MPLS_PW_RDI
Added MPLS_PW_SD
Added MPLS_PW_SF
Added MPLS_PW_UNEXPMEG
Added MPLS_PW_UNEXPMEP
Added MPLS_PW_UNEXPPER
Added MPLS_TUNNEL_AIS
Added MPLS_TUNNEL_LOCV
Added MPLS_TUNNEL_OAMFAIL
Added MPLS_TUNNEL_RDI
Added MPLS_TUNNEL_SD
Added MPLS_TUNNEL_SF
Added MPLS_TUNNEL_UNEXPMEG
Added MPLS_TUNNEL_UNEXPMEP
Added MPLS_TUNNEL_UNEXPPER
Added PORT_EXC_TRAFFIC
Added PW_APS_DEGRADED
Added PW_APS_OUTAGE
Added PW_NO_TRAFFIC
Added PWAPS_LOST
Added PWAPS_PATH_MISMATCH
Added PWAPS_SWITCH_FAIL
Added PWAPS_TYPE_MISMATCH
Added TUNNEL_APS_DEGRADED
Update Description
Added TUNNEL_APS_OUTAGE
Board Alarm List
Added DP212 Board Alarm List
Added DP401 Board Alarm List
Added MP12 Board Alarm List
Added HP401 Board Alarm List
Added LQM Board Alarm List
Added LTX Board Alarm List
Added LWXS Board Alarm List
Added TOM Board Alarm List
Modified LSX Board Alarm List
Modified NS3 Board Alarm List
Modified NS4 Board Alarm List
Handling Performance Events
Added ETH_CFM_LS
Added ETH_CFM_SLS
Added ETH_CFM_CSLS
Added ETH_CFM_UAS
Added MPLS_PW_LS
Added MPLS_PW_SLS
Added MPLS_PW_CSLS
Added MPLS_PW_UAS
Added MPLS_TUNNEL_LS
Added MPLS_TUNNEL_SLS
Added MPLS_TUNNEL_CSLS
Added MPLS_TUNNEL_UAS
Added OSPITMP
Added RPL
Added TLB
Added TPL
Board Performance Event List
Added DP212 Board Performance Event List
Update Description
Update Description
Board Performance Event List Modified T302 Board Performance Event List.
Update Description
Added ETH_ES.
Added ETH_SES.
Added ETH_SESR.
Added ETH_UAS.
Configuring Services and Features
Added Configuring Optical Line Protection.
Multimedia presentation of information is
adopted for the following features:
Client 1+1 Protection: Principles.
Intra-Board 1+1 Protection: Principles.
Optical Line Protection: Principles.
ODUk SNCP: Principles.
Tributary SNCP: Principles.
Configuring ODUk SNCP:
Update Description
Line Rate:
LPT: Introduction.
ODUk SNCP: Principles.
Update Description
>ODU1) is added.
N302: The TNU1N302 is added.
Technology Reference
100G and 40G Coherent Transmission Systems :
Update Description
Supported Services
Service Mapping: Added Service mapping on
boards.
Relationships.
Product Alarm List: Added Control Plane
Alarms.
Board Alarm List: Modified CTU Board
Alarm List.
Feature
This section lists the new or modified features and update details in each SPC version.
Hardware
This section lists the new or modified hardware and update details in each SPC
version.
Alarm
This topic lists the new or modified alarms and update details in each SPC.
Performance Event
This section lists the new or modified performance events and update details in each
SPC version.
transmission systems.
A pluggable QSFP28 optical module is newly
supported.
100G and 40G
Coherent Transmission
Modified New 100G OTU board is required to improve
Systems
the grooming capability of coherent systems.
A pluggable QSFP28 optical module is newly
supported.
OTN Overheads
Technology
Modified Added the support for setting MSI Auto Enable
to Semi-Auto on TNU3N402 and TNU3N401
boards.
added.
The OD newly supports OSNR detection in
the FlexGrid system.
Using the FD System
for Fiber Quality
Modified TN11AST2 board is added to support the fiber
Monitoring quality monitoring function.
ASON
New The ASON, the automatically switched optical
network, is a new generation of the optical
transmission network, or called ASON optical
network. To support ASON, you must purchase
an ASON license.
PID
New On a WAN, a 200G/400G aggregation ring
based on PID boards (NP400 and NP400E) only
is recommended, eliminating commissioning
while enabling quick service provision.
Feature Name Update Type Description
ERPS
New Based on the automatic protection switching
(APS) protocol and protection switching
mechanism, Ethernet ring protection switching
(ERPS) defines a protocol for Ethernet ring
protection. ERPS is applicable to the Ethernet
ring topology at the Ethernet Layer 2, and
provides protection for E-LAN services on an
Ethernet ring.
LMSP (OCS)
New Using TDM boards and line boards, the LMSP
provides dual-feeding and selective receiving to
implement protection switching and protect
services. The LMSP supported by OptiX OSN
equipment adopts the 1+1 single-ended
switching mode.
SNCP
New Sub-network connection protection (SNCP) uses
TDM boards and line boards to implement dual
feed and selective receiving and protection
switching for protecting inter-subnet services.
IP over DCC
New In the IP over DCC solution, NEs use unified
DCC channels to transmit the TCP/IP protocol
packets, enabling the U2000 to manage them.
The IP over DCC solution can be applied on a
network that consists of OptiX transmission
equipment and third-party equipment that
supports the IP over DCC function, as well as a
network that consists of only OptiX transmission
equipment.
Inband DCN
New Inband DCN implements network equipment
management using service channels provided
by the managed equipment. Network
Feature Name Update Type Description
QinQ
New QinQ is a Layer 2 tunnel protocol based on IEEE
802.1q encapsulation. The QinQ technology
encapsulates a private virtual local area network
(VLAN) tag into a public VLAN tag. Therefore,
the packets with two layers of VLAN tags can be
transmitted on the backbone network of a
carrier. In this manner, QinQ provides Layer 2
virtual private network (VPN) tunnels.
IGMP Snooping
New In a MAN where multicast services (for example,
IPTV) are deployed, the Internet Group
Management Protocol (IGMP) Snooping
protocol is usually used on the Layer 2 network
to enhance the management of multicast
services and therefore to prevent a bandwidth
waste caused by multicast video streams at the
Layer 2 network.
Product Specifications
Modified Added the support for VC service grooming and
the SDH service license.
ROADM
Modified Added the 20-degree ROADM grooming
solution.
Feature Name Update Type Description
Intra-Board 1+1
Protection
Modified The LDX board newly supports intra-board 1+1
bidirectional switching by interoperating with
the OLP/DCP/QCP board. Bidirectional
switching indicates that protection switching is
performed at both the transmit and receive
ends for a bidirectional service, so that the
bidirectional service is always transmitted and
received over the same route.
ODUk SNCP
Modified SNC/I, SNC/S, and TCM-layer SNC/N SNCP
protection are supported for ODUflex signals.
MC-LAG
Modified ETH-carried MCSP channels are newly
supported.
IPA
Modified Extended IPA is added. When the system
control board in the master subrack fails, the
IPA function is still working to improve system
security.
Feature License
Modified Added: 1*100G/200G Programmable Line
License, applicable to the N401P board.
Feature License
Modified Deleted the Description of "SAN port function
license".
CES/CEP Services
New The CES/CEP helps to solve the problem of
insufficient optical fiber resources in the access
ring and allows TDM services to be
transparently transmitted across the pure
packet mode.
LMSP (Packet)
New The linear multiplex section protection (LMSP)
uses the K1 and K2 bytes in multiplex section
(MS) overheads to achieve automatic protection
switching, providing protection for AC-side
links. LMSP is mainly applicable to the scenario
where the OptiX OSN 9800 and radio network
controller (RNC).
MC-LMSP
New The multi-chassis linear multiplex section
protection (MC-LMSP) supports that the
Feature Name Update Type Description
TDM PWE3
New The TDM PWE3 technology emulates the basic
behaviors and characteristics of TDM services
on a packet switched network (PSN) by using
the PWE3 mechanism, so that the emulated
TDM services can be transmitted on a PSN.
Physical Clocks
Modified The U2000 graphical user interface (GUI) for
physical clocks of OptiX OSN 9800
U64/U32/U16 subracks is modified.
IEEE 1588v2
Modified The U2000 graphical user interface (GUI) for
IEEE 1588v2 clocks of OptiX OSN 9800
U64/U32/U16 subracks is modified.
Product Specifications
Modified Added the support for packet service grooming.
Intra-Board 1+1
Protection
Modified The QCP board (four-channel protection board)
is added to support intra-Board 1+1 protection,
Feature Name Update Type Description
Intra-NE
Communication
Modified OptiX OSN 9800 U64/U32 does not support
Management Based on master-slave subrack configurations from OSN
Master-Slave Subrack
Configuration 9800 V100R001C30.
U2000 Web LCT Modified OptiX OSN 9800 U64/U32 does not support
operations on the U2000 Web LCT from OSN
9800 V100R001C30.
IP over DCC Deleted The IP over DCC is deleted from OSN 9800
V100R001C30, and will be supported by OSN
9800 V100R002C10 and later versions.
PID
New On a WAN, a 200G/400G aggregation ring
based on PID boards (NP400 and NP400E) only
is recommended, eliminating commissioning
while enabling quick service provision.
diagnosis.
100 Gbit/s
Modified Added 100 Gbit/s Metro Solution.
Intra-Board 1+1
Protection
Modified The LDX board newly supports intra-board 1+1
bidirectional switching by interoperating with
the OLP/DCP/QCP board. Bidirectional
switching indicates that protection switching is
performed at both the transmit and receive
ends for a bidirectional service, so that the
bidirectional service is always transmitted and
received over the same route.
Feature License
Modified Added the Description of "Per 100G Capacity
Expansion Fee (Greater than 100G Line Card)".
Feature License
Modified Deleted the Description of "SAN port function
license".
Flexible ROADM
New Flexible ROADM improves spectrum utilization
and satisfies the requirements for flexible rate
grooming of future beyond 100 Gbit/s.
Synchronization
New Physical Clocks and IEEE 1588v2 are newly supported
to satisfy the requirements for providing high-
precision network clocks.
performance.
OTN Overheads
Modified Board MSI bytes can be configured, satisfying
the requirements for interconnection
between Huawei boards and third-party
boards.
The boards newly support the configuration
of AIS Insertion Enabling of PLM and AIS
Insertion Enabling of MSIM to control
whether the OPUk_PLM and OPUk_MSIM
alarms are used as the conditions for
triggering client 1+1 protection, ODUk SNCP,
or tributary SNCP.
Client 1+1 Protection
Modified The working and protection OTU boards can
be different types.
The OPUk_PLM and OPUk_MSIM alarms are
added as conditions for triggering client 1+1
protection switching.
Intra-Board 1+1
Protection
Modified The LOA and LQM boards start to support the
switching detection time parameter. They are
applicable to the cascading protection or nested
protection scenario.
Optical Line Protection
Modified OLP bidirectional switching is newly supported.
This feature update is to address the scenario in
which protection switching needs to be
performed at both the transmit and receive
ends for a bidirectional service. This ensures
that the bidirectional service is always
transmitted and received over either the
working or the protection route.
ODUk SNCP
Modified The OPUk+m_PLM and OPUk_MSIM alarms are
added as conditions for triggering ODUk SNCP
protection switching.
Tributary SNCP
Modified The OPUk+m_PLM and OPUk_MSIM alarms are
Feature Name Update Type Description
1.10.2 Hardware
This section lists the new or modified hardware and update details in each SPC
version.
TN52DAP
New The DAP board is a dual-channel pluggable
optical amplifier board that amplifies optical
signals. The DAP board can be used at either the
transmit end or the receive end.
Hardware Name Update Type Description
TN52DAPXF
New The DAPXF board supports dual pluggable
optical amplifier units. The DAPXF board is used
to amplify optical signals, multiplex and
demultiplex the optical supervisory channel and
main optical channel. The DAPXF board can be
used at either the transmit end or the receive
end.
TN13VA1,
TN13VA4, and
TN11DCU
TNV3T404 and Modified Added the support for Client Service Encryption
TNU1G404
on the TNV3T404 board.
TN51DWSS20
New TN51DWSS20 board support 96 wavelengths and
extended C-band.
TN96WSD9, Modified Added the support for TN96WSD9, TN96WSM9,
TN96WSM9, TN97TM20, TN97TD20, D48, M48V, and
TN97TM20, TN97OPM8 application in terrestrial systems and
TN97TD20, D48, end-to-end extended C-band.
M48V, and
TN97OPM8
TNV1T216, Modified Added the support for ODUk loopback on the
TNV1T210, boards.
TNV2T220,
TNV2T210,
TNV3T230,
TNV3T210,
TNV3T220,
TNV3T404,
TNV2T220E,
TNV3T401,
TNV3T402,
TNU1G404,
TNU1G402,
TNV2G220, and
TNV2G210
TNV1T130, Modified Added the support for idle code on the boards.
TNV1T216,
TNV2T220,
TNV2T210,
TNV3T230,
Hardware Name Update Type Description
TNV3T210,
TNV3T220,
TNV3T404,
TNV2T220E,
TNV3T401,
TNV3T402,
TNU1G404,
TNU1G402,
TNV1U210,
TNV2U210,
TNU2U401,
TNU3U401,
TNU4U401,
TNU4U402,
TN18LSC,
TN11LOA, and
TN14LSX
100GBASE-ER4-40km-CFP2
100GBASE-SR10-100m-CFP2
The board supports the ITU-T G.8275.1 p
The board supports the IEEE 1588v2.
The board supports the Physical clock.
TNU4U402
New The boards support hybrid transmission of
and packet services and perform conversion
service signals and one channel of OTU4 sig
The boards support Layer 2 switching, MPL
OTN interfaces.
Gray light optical module: Supports FEC
Other modules: Supports SDFEC2 and HF
encoding.
TNU4U401
New Compared with other U401 boards, TNU4U
supports pluggable optical modules, SDFEC
HFEC PLUS on the WDM side.
U210
Modified Added the support for PW FPS protection o
board.
Added the support for the packet service p
against multiple fiber cuts on the U210 boa
U401
Modified Added the support for PW FPS protection o
board.
Added the support for the packet service p
against multiple fiber cuts on the U401 boa
TNV1E124
Modified Added the support for 2.125 Gbit/s Multira
eSFP optical module on the TNV1E124 boa
TNV1E124/TNV1E208/TNV1E212/TNV1E302/TNV1E401
Modified Added the support for PW FPS protection o
TNV1E124/TNV1E208/TNV1E212/TNV1E302
board.
TNV1E208/TNV1E212
Modified Added the support for 10 Gbit/s Single-Rat
XFP optical module on the TNV1E208/TNV1
Hardware Name Update Description
Type
board.
TNV1E401
Modified Added the support for 100GBASE-SR10-100
optical module on the TNV1E401 board.
V3T230/V3T220/V3T210
Modified Added the support for Client Service Encryp
V3T230/V3T220/V3T210 board.
TN17LSC
Modified The TN17LSC board supports the regenerat
TNV1S216
Modified TNV1S216 board supports AU-3 services, co
three AU-3 signals into one AU-4 signal, an
lower-order grooming on VC-3/VC-12 sign
TNU3N401T51/TNU3N401T58/TNU3N401T
added the support for PMD Threshold(ps) p
N402 Modified TNU3N402added the support for port-Leve
TNU3N402T51/TNU3N402T58/TNU3N402T
added the support for PMD Threshold(ps) p
N401P Modified Added the support for PMD Threshold(ps) p
U210 Modified Added the support for LPT function and po
U401 Modified Added the support for LPT function and po
TNU3U401T51/TNU3U401T58/TNU3U401T
the support for PMD Threshold(ps) parame
TNV1E124/TNV1E208/TNV1E212/TNV1E302/TNV1E401 Modified Added the support for LPT function and po
TN11LOA Modified Added the support for the ISC 1G, ISC 2G se
TN17LSC Modified The TN17LSCT51/TN17LSCT58/TN17LSCT61
added the support for PMD Threshold(ps) p
TN17LTX Modified Added the support for InfiniBand 5G service
TN58NS4 Modified TN58NS4T51/TN58NS4T58/TN58NS4T61/T
newly support for PMD Threshold(ps) param
TN13ST2 Modified The TN13ST2 board newly supports the ITU
STG Modified The board newly supports the ITU-T G.8275
TNU5N402 New Compared to the other N402 board, the TN
supports the pluggable colored-light optica
OTDR meter.
TN12RAU201E
Modified Compared with the TN12RAU201
board, the TN12RAU201E board
newly supports an RFM optical
port that can be connected to an
OTDR meter.
TN13STG
Modified Compared with The TN12STG, the
TN13STG board is manufactured
using an optimized engineering
process. The function does not
change.
TN58NS4T31 Modified The TN58NS4T31 board can
substitute for the TN57NS4T31
board and occupies only one slot.
TNV1SXCL New SXCL is the cross-connect board
that cross-connects and protects
VC-3 and VC-12 signals inside a
subrack.
TNV1E124
Modified Added the support for single-
fiber bidirectional transmissions
GE optical module on the
TNV1E124 board.
TNV2N220 New The TNV2N220 board must be
used to perform the following
conversion:
160 x ODU0/160 x ODUflex/80 x
ODU1/20 x ODU2<->20 x OTU2
or 20 x ODU2e<->20 x OTU2
TNV3T404 New (100 GBASE-4×25G)/(OTU4-4×
28G)-10 km-CFP2
100G BASE-ER4-40 km-CFP2
100G BASE-SR10-100 m-CFP2
Hardware Name Update Description
Type
board.
TNV1T401
Modified Added the support for the
100GBASE-ER4-40km-CFP
module on the TNV1T401 board.
TNV1T401
Modified Added the support for the
100GBASE-ER4-40km-CFP
module on the TNV1T402 board.
TNV1N210
Modified Added the support for ODUflex-
layer TCM overhead processing
on the board.
TNV1N216
Modified Added the support for ODUflex-
layer TCM overhead processing
on the board.
TNV1N302
Modified Added the support for ODUflex-
layer TCM overhead processing
on the board.
TNU1N302
Modified Added the support for ODUflex-
layer TCM overhead processing
on the board.
TNU1N401 Modified Added the support for ODUflex-
layer TCM overhead processing
on the board.
TNU2N401 Modified Added the support for ODUflex-
layer TCM overhead processing
on the board.
TNV1N401 Modified Added the support for ODUflex-
layer TCM overhead processing
on the board.
TNV2N401 Modified Added the support for ODUflex-
layer TCM overhead processing
on the board.
TNU1N402 Modified Added the support for ODUflex-
layer TCM overhead processing
on the board.
Hardware Name Update Type Description
TNV1E124 board.
TNV2G210/TNV2G220 Modified Added the support for
ODUflex-layer TCM overhead
processing on the board.
Added the support for
FC800/FINCON8G/FC1200
services on the client side.
The 10GE
LAN/FC800/FICON8G services
on the client side of the
TNV2G210/TNV2G220 board
can be encapsulated into
ODUflex signals.
MAN.
EC116/EC404
New TNV1EC116/TNV1EC404 support TDM
PWE3.
TNV1EC116: provides sixteen
channelized STM-1 interfaces and
supports CES/CEP services.
TNV1EC404: provides fourchannelized
STM-4 interfaces and supports CES/CEP
services.
TN12LOG
New LOG converts signals: 8 x GE <->1 x OTU2.
TN12TMX
New TMX converts signals as follows: 4x STM-
16/OC-48/OTU1<->1x OTU2.
TN17LSCM
New Added the 05, 06, 07, 08, 09, and 10 types
of TN17LSCM boards. The new TN17LSCM
boards provide enhanced functions and
can support 80 wavelengths.
TN15LTX
Modified The TN15LTX board added the support for
optical module 10 Gbit/s Multirate-80 km-
SFP+.
Power Supply
Modified The UPS subrack newly supports AC power
supply. Each AC power cable is directly
connected to the external AC power
supply and APIU.
TN11LTX
New LTX converts signal: 10 x 10GE LAN/10GE
WAN/STM-64/OC-192<->1 x OTU4. The
Hardware Name Update Type Description
TN15LTX
New Compared with the TN12LTX board, the
TN15LTX supports FC1200/FC800 services.
TN15LTX supports SDFEC2, occupies two
slots. The TN15LTX board can be used on
the 9800 Universal Platform Subrack.
TNV1U210
New It supports hybrid transmission of OTN and packet
services and performs conversion between service
signals and 10 channels of OTU2/OTU2e signals. It
supports Layer 2 switching, MPLS-TP, and OTN
interfaces.
TNU2U401
New The boards support hybrid transmission of OTN and
packet services and perform conversion between
service signals and one channel of OTU4 signal. The
boards support Layer 2 switching, MPLS-TP, and OTN
interfaces.
TNU2N401 board.
The TNU3N401 board can substitute
for the TNU2N401 board.
TNU3N402 New 100 Gbit/s SDFEC2 line board.
The TNU3N402 board has lower
power consumption than the
TNU2N402 board.
The TNU3N402 board can substitute
for the TNU2N402 board.
TNU2N501 New Compared with the TNU1N501 board
whose capacity is fixed to 200G, the
TNU2N501 board can be expanded from
100G to 200G.
TNU2N601 New Compared with the TNU1N601 board
whose capacity is fixed to 400G, the
TNU2N601 board can be expanded from
100G to 400G.
TNU1NP400/TNU1NP400E New The NP400 board and NP400E board are
Turbo WDM board that occupies only
one slot.
The NP400 board can be
independently used in a 200G system
or work with the NP400E board in a
400G system.
The NP400E board must work with the
NP400 board in a 400G system.
TN12LDX New The TN12LDX board must be used to
perform the following conversion:
2 x 10GE LAN/10GE WAN/STM-
64/OC-192/OTU2 <-> 2 x OTU2.
2 x 10GE LAN/OTU2e <-> 2 x OTU2e.
TN12LOG New The LOG board implements conversion
between eight channels of GE optical
Hardware Name Update Type Description
1.10.3 Alarm
This topic lists the new or modified alarms and update details in each SPC.
MAC_FCS_NUM_SD
New This alarm indicates signal degrade
detected at the MAC layer based on the
number of FCS packets.
MAC_FCS_NUM_EXC
New This alarm indicates a bit error threshold-
crossing detected at the MAC layer based
on the number of FCS packets.
NEIP_CONFUSION
New There might be existing NEs with the same
IP in the network.
PATCH_INIT_FAIL
New This alarm is generated when the patch
initialization fails.
PATCH_OP_TIMEOUT
New Patch package operation timeout.
SUBCARD_COM_FAIL
New This alarm is reported when the
communication between the CPU module
of the board and the subcard fails.
SUBCARD_MISMATCH
New Subcard mismatch. This alarm is reported
when the subcard that is not supported is
inserted to the board.
SUBCARD_OFFLINE
New Subcard being offline. This alarm is
reported when the subcard of the board is
offline or the subcard hardware is faulty.
SUBCARD_TEMP_OVER
New Sub-card working temperature threshold-
crossing.
SUBCARD_UPGRADE_FAIL
New Subcard file upgrade failure.
loss is changed.
PORT_WLLCFG_REPEATED
New Repeated wavelength locking configurations
are present on an optical port of an OTU
board.
STORAGE_FAIL
New A storage error alarm. This alarm occurs
when there is an error in the storage.
WAVELEN_REPEATED
New Repeated wavelengths in the wavelength
locking configurations.
B3_EXC_VC3
New The number of lower order path (LP)
VC-3 B3 bit errors exceeds the specified
threshold. This alarm is generated when
a board detects that the number of the
VC-3 bit errors exceeds the B3_EXC
alarm threshold by monitoring the B3
byte.
B3_SD_VC3
New The number of the VC-3 B3 bit errors
exceeds the specified threshold. This
alarm is generated when a board
detects that the number of the VC-3 bit
errors exceeds the B3_SD alarm
threshold by monitoring the B3 byte.
BIOS_STATUS
New An alarm indicating the BIOS status.
Alarm Name Update Type Description
FC_AIS
New An FC service alarm indication signal
HP_LOM
New A higher order path (HP) multiframe is
lost.
LASER_TYPE_MISMATCH
New Mismatch of optical module types. This
alarm is reported when the type of the
inserted optical module does not match
the type of the optical module that is
previously inserted,or,the optical
module is not authorized by Huawei.
LASER_PARA_ERR
New The parameter stored in the optical
module is missing or incorrect.
LP_RDI_VC3
New A remote receive failure on the VC-3
path. This alarm is generated when a
board detects bit 5 of the G1 byte is 1
for the VC-3 path.
LP_REI_VC3
New A remote error indication alarm in the
lower order path. When a board has
detected that any of bits 1~4 in the G1
byte is 1,the LP_REI_VC3 alarm is
reported.
LP_SLM_VC3
New A mismatch between C2 bytes
identifying VC-3 signals.
LP_TIM_VC3
New The trace identifier J1 mismatch of the
lower order VC-3 path. This alarm
occurs when the board detects the J1
byte mismatch.
Alarm Name Update Type Description
LP_UNEQ_VC3
New The VC-3 path carries no service. This
alarm is generated when a board
detects that the C2 byte is 0.
LSR_KEY_UNLOCK
New Front panel key unlocked alarm.
MCS_SWITCH_BLOCKED
New The MCS switch is blocked.
MPN_APS_INDI
New This alarm indicates the status of an
MPN protection group.When this alarm
occurs, the protection group is in the
SF/SD state or the external command
switching state.
MPN_OPPOSITE_CFG_ERR
New This alarm indicates the MPN
configuration of the peer NE is
incorrect.
MPN_APS_STOP
New This alarm indicates the automatic
switching protocol of MPN protection is
stopped.
ODC_DOOR_OPEN
New The cabinet door is open or the door
sensor is faulty or is connected
incorrectly.
ODU_SNCP_WEAK
New ODUk SNCP weak protection capability.
This alarm is generated on the board of
working channel when the working and
protection channels of a protection
group are configured on the same OTU
board.
Alarm Name Update Type Description
ORP_CRITICAL_HI
New Excessively high reflection power. This
alarm is generated when the reflection
power exceeds threshold.
OSC_CLK_MISMATCH
New This is an OSC clock conflict alarm.
When the IEEE 1588 protocol is enabled
on the TN11AST2 board and the board
is in the clock source priority table, but
the TN11AST2 board and the clock
board or cross-connect board
mismatch, this alarm will be reported.
RACK_CONFLICT_SCREEN
New The subrack ID conflict caused by
incorrect connections between device
cascading ports.
SCC_CHANGE
New The SCC board is replaced.
TU_LOP_VC3
New A pointer loss in the lower order VC-3
TU channel. This alarm is generated
when a board detects that the TU-PTR
value is invalid or NDF reverses in eight
consecutive frames.
TU_AIS_VC3
New An alarm indication signal (AIS) for a
lower order VC-3 TU channel. This
alarm is generated when the board
finds that signals in the TU channel are
all "1"s.
XCP_DEGRADE
New Protection capability degrade indication
of cross-connect boards.This alarm is
reported when the external switching
Alarm Name Update Type Description
B3_EXC_VC3
New The number of lower order path (LP) VC-
3 B3 bit errors exceeds the specified
threshold.
B3_SD_VC3
New The number of the VC-3 B3 bit errors
exceeds the specified threshold.
BIOS_STATUS
New An alarm indicating the BIOS status.
LASER_TYPE_MISMATCH
New Mismatch of optical module types.
LASER_PARA_ERR
New The parameter stored in the optical
module is missing or incorrect.
LP_RDI_VC3
New A remote receive failure on the VC-3
path.
Alarm Name Update Type Description
LP_REI_VC3
New A remote error indication alarm in the
lower order path.
LP_SLM_VC3
New An alarm indicating a mismatch between
C2 bytes identifying VC-3 signals.
LP_TIM_VC3
New An alarm indicating the trace identifier
J1 mismatch of the lower order VC-3
path.
LP_UNEQ_VC3
New An alarm indicating that the VC-3 path
carries no service.
LSR_KEY_UNLOCK
New Abnormal board interlock switch.
ODU_SNCP_WEAK
New ODUk SNCP weak protection capability.
ODUCN_PM_LCK
New ODUCN PM signals being locked.
POWER_SAMPLE_DIFF
New The current optical power of the
protection channel is inconsistent with
the sampling optical power.
RACK_CONFLICT_SCREEN
New The board isolates the subrack ID
conflict caused by incorrect connections
between device cascading ports.
TU_LOP_VC3
New A pointer loss in the lower order VC-3
TU channel.
TU_AIS_VC3
New An alarm indication signal (AIS) for a
lower order VC-3 TU channel.
Alarm Name Update Type Description
XCP_DEGRADE
New Protection capability degrade indication
of cross-connect boards.
CPU_BUSY
New The CPU_BUSY is an alarm indicating that
the CPU utilization is excessively high.
When the board detects that the CPU
utilization reaches the upper limit, this
alarm occurs.
ELAN_AUTO_LOOP
New The ELAN_AUTO_LOOP alarm indicates
an E-LAN loop detected by automatic
loop detection. When a device receives
loop detection packets sent by itself, it
considers that an E-LAN loop has
occurred and services may be
interrupted. Therefore, it reports the
ELAN_AUTO_LOOP alarm.
ELAN_LDT_IF_BLOCKED
New The ELAN_LDT_IF_BLOCKED alarm
indicates that an ELAN service interface
is blocked. When an ELAN service
interface is blocked, the
Alarm Name Update Type Description
ELAN_LDT_IF_BLOCKED alarm is
reported.
ELAN_SMAC_FLAPPING
New The ELAN_SMAC_FLAPPING alarm
indicates that the source MAC address
learned by an E-LAN service undergoes a
transfer. This alarm is reported when two
ports on a bridge or VSI learn the same
source MAC address.
ENV_TEMP_OVER
New The ENV_TEMP_OVER alarm is generated
if the device's ambient temperature
increases above the upper limit or drops
below the lower limit.
HP_CROSSTR
New The HP_CROSSTR alarm indicates that
high order path bit errors crosses the
threshold. The HP_CROSSTR is an alarm
indicating that the number of the higher
order path bit errors crosses the
threshold.
MEM_OVER
New The MEM_OVER alarm indicates that the
memory utilization is too high. This alarm
occurs when a board detects that the
memory utilization is higher than the
threshold.
MS_CROSSTR
New Multiplex section performance exceeds
the threshold. The alarm is generated
when the performance module reports
threshold-crossing performance events
in the multiplex section.
Alarm Name Update Type Description
PTP_ATTR_MISMATCH
New The PTP_ATTR_MISMATCH alarm is
generated if configurations on the two
PTP points do not match.
PTP_OFFSETSUM_OVER
New The PTP_OFFSETSUM_OVER alarm
indicates that the difference of the PTP
time offsets exceeds threshold. The PTP
time offsets are accumulated periodically
in specified periods. When the difference
between the maximum and minimum
accumulated PTP time offsets exceeds
the threshold, the
PTP_OFFSETSUM_OVER alarm is
generated.
PTPSRC_CLKCLS_DEC
New The PTPSRC_CLKCLS_DEC alarm indicates
that the quality of the 1588 time input
source degrades.
RXCFG_WAVEDATA_MIS
New The RXCFG_WAVEDATA_MIS alarm
indicates that the physical receive
wavelength or band attribute (odd or
even) of an optical module is different
from the logical receive wavelength or
band attribute set by a user. This alarm is
reported when the receive wavelength or
band attribute settings mismatch on a
board and an NE.
STD_PTP_OFFSET_OVER
New The STD_PTP_OFFSET_OVER alarm
indicates that the offset of the external
reference time from the PTP time
exceeds the threshold. When a device
Alarm Name Update Type Description
TDM Alarms
New Added the support for TDM features and
the related alarms.
BIP_EXC
New The BIP_EXC is an alarm indicating that
BIP BER exceeds the specified threshold
BIP_SD
New The BIP_SD is an alarm indicating that
BIP signals are degraded.
FORCED_INSERT_AIS
New The FORCED_INSERT_AIS alarm is
generated if an AIS is forcibly sent to an
interface. The service is interrupted.
MC_LMS_CFG_MISMATCH
New The MC_LMS_CFG_MISMATCH is an
alarm indicating the configuration of the
multi-chassis linear multiplex section
(MC_LMS) protection group mismatch.
When creating an MC_LMS protection
group, if the configuration on the
working NE is inconsistent with the
configuration on the protection NE, this
alarm occurs.
Alarm Name Update Type Description
ODUCN_PM_AIS
New ODUCn PM alarm indication signal. An
AIS signal is transmitted to the
downstream station, indicating that a
signal failure is detected at the upstream
station.
ODUCN_PM_BDI
New ODUCn PM backward defect indication.
This alarm is generated when the PM
section at the opposite station detects a
signal failure and inserts a BDI alarm to
the local station.
ODUCN_PM_DEG
New ODUCn PM signal degraded. This alarm
is generated if signal degradation occurs
or the bit error count exceeds the
threshold when the BIP8 detection is in
burst mode and generated if signal
degradation occurs when the BIP8
detection in poisson mode.
ODUCN_PM_SSF
New Failure of ODUCn PM server-layer
signals.
ODUCN_PM_TIM
New Mismatch of the ODUCn PM trace
identifier. This alarm is generated during
control process when the trace identifier
at the opposite end mismatches that at
the local end when the TIM detection is
enabled.
OPUCN_MSIM
New OPUCn multiplex structure identifier
mismatch.
Alarm Name Update Type Description
OPUCN_PLM
New OPUCn payload mismatch. The type of
received payload mismatches the
expected payload type defined in the
adaptation function.
OTUCN_BDI
New OTUCn backward defect indication. This
alarm is generated when the SM section
detects a signal failure and the value of
the BDI byte is 1.
OTUCN_DEG
New The OTUCn_DEG is an alarm indicating
that the OTUCn signal is degraded.
When the BIP8 detection is in burst
mode, this alarm is generated if the
signal degradation or bit error count
exceeds the threshold. In addition, when
the BIP8 detection in poisson mode, this
alarm is generated if the signal
degradation exceeds the threshold.
OTUCN_LOF
New The OTUCN_LOF is an alarm indicating
that the frame alignment signal (FAS) is
abnormal. This alarm occurs when the
frame alignment processing is out of
frame (OOF) in three consecutive
milliseconds.
OTUCN_LOM
New The OTUCN_LOM is an alarm indicating
that the multiframe alignment signal
(MFAS) is abnormal. This alarm occurs
when the multiframe locating is out of
multiframe (OOM) in three consecutive
milliseconds.
Alarm Name Update Type Description
OTUCN_SSF
New The OTUCN_SSF is an alarm that the
signal fails at the OTUCn server layer.
OTUCN_TIM
New OTUCn trail trace identifier (TTI)
mismatch. This alarm is generated
during the control process when the TTI
at the opposite end mismatches that at
the local end if the TIM detection is
enabled.
PWD_ENCRYPT_RISK
New User password encryption mode risk
alarm. This alarm is generated when a
user performs the following operations:
CFP_LOS
New Loss of signals in CFP module. This
alarm is generated when the receive
end of the channel on the CFP module
receives no signal.
HARD_NONSUPPORT
New This alarm indicates that the hardware
Alarm Name Update Type Description
RMON_ALM_INBADOCTS_OVER
New Statistics of receiving bad packets is
over the upper threshold. The alarm is
generated when the octet number of
bad packets detected by the Ethernet
port of the board crosses the upper
threshold.
SWDL_BD_WEAKMATCH
New Weak matching between board
software and NE software. This alarm
is reported when the software of
boards on an NE weakly matches the
NE software.
TIME_LOCK_FAIL
Modified Deleted the 0x04 value from
parameter 5 of the alarm.
Packet Alarms
New Added packet service alarms.
ALM_ALS
New The ALM_ALS is an alarm indicating
automatic laser shutdown. This alarm is
generated when the laser is automatically
shut down due to the R_LOS alarm
generated for the optical port.
CFG_DATASAVE_FAIL
New Failure to save configuration data. This
alarm is reported when configuration fails
to be saved in the database.
Alarm Name Update Type Description
CFG_DATACHECK_FAIL
New Database check error alarm. The database
will be checked during the NE running. If
the database check fails, a database
check failure alarm will be reported.
IN_PWR_ABN
New The IN_PWR_ABN is an alarm indicating
that the input optical power is abnormal.
LASER_MOD_ERR
New The LASER_MOD_ERR is an alarm
indicating mismatch of optical modules.
When the type of the optical module
inserted does not match the type
supported by the board, this alarm
occurs.
LASER_OPEN_FAIL
New Laser turn-on failure alarm. This alarm is
reported when the laser fails to be turned
on because the line fiber quality
monitoring results do not satisfy the
requirements.
LSR_BCM_ALM
New The LSR_BCM_ALM is an alarm indicating
that the bias current of the laser crosses
the threshold. If the bias current of the
laser crosses the threshold, the
LSR_BCM_ALM alarm is reported.
LSR_NO_FITED
New The LSR_NO_FITED is an alarm indicating
that the laser is not installed. This alarm is
generated when the optical port is
enabled but has no optical modules
installed.
Alarm Name Update Type Description
OUT_PWR_ABN
New The OUT_PWR_ABN is an alarm indicating
that the output optical power is
abnormal.
POWER_ABNORMAL
New The POWER_ABNORMAL is an alarm
indicating a power supply failure. This
alarm is generated when the power
supply of a board becomes abnormal.
RMT_DEV_DYING_GASP
New RMT_DEV_DYING_GASP is an alarm
indicating the power-off notice sent by
the remote device.
TEMP_HEAT
New The TEMP_HEAT alarm is generated if the
ambient temperature in which the board
works greatly crosses the upper or the
lower limit.
W_OFFLINE
New The W_OFFLINE alarm indicates that the
ejector lever of a board is out of position.
When the ejector lever of a board is
rotated to the open position, the
W_OFFLINE alarm is reported.
TIME_LOCK_FAIL
New Time lock failure alarm. When the time of
an NE is synchronized from the upstream
NE, the time lock status is locking. When
the time of an NE is not locked, this alarm
is reported to remind the user of the
unlock status of the NE time.
PRO_PKT_FLOODING
New Protocol packet flooding attacks
detected alarm. This alarm is reported
when the rates of protocol packets
received by a device exceed the upper
rate threshold for 30 consecutive
seconds.
SHELF_POWER_UNCONFIG
New The power consumption threshold of a
subrack is not configured. This alarm is
reported if the power consumption
threshold of a subrack is not configured
during new deployment or after the NE
database is cleared and the NE is reset.
CFP_LOS
New Loss of signals in CFP module. This
alarm is generated when the receive
end of the channel on the CFP module
receives no signal.
CPC_NE_UPGRADE_LOCK
New The CPC_NE_UPGRADE_LOCK alarm
indicates that an ASON NE is locked
for an upgrade.
CPW_ODU_TEL_MAINTAIN
New The CPW_ODU_TEL_MAINTAIN alarm
indicates that the ODU TE link in the
OTN domain is in the maintenance
status. If the TE link is in the
maintenance status, this alarm is
reported. If the maintenance status of
Alarm Name Update Type Description
CPW_OTU_TEL_MAINTAIN
New The CPW_OTU_TEL_MAINTAIN alarm
indicates that the OTU TE link is in the
maintenance status. If the TE link is in
the maintenance status, this alarm is
reported. If the maintenance status of
the TE link is canceled, the alarm is
cleared.
HARD_NONSUPPORT
New This alarm indicates that the hardware
does not support the configuration.
ODUCN_PM_AIS
New ODUCn PM alarm indication signal. An
AIS signal is transmitted to the
downstream station, indicating that a
signal failure is detected at the
upstream station.
ODUCN_PM_BDI
New ODUCn PM backward defect
indication. This alarm is generated
when the PM section at the opposite
station detects a signal failure and
inserts a BDI alarm to the local station.
ODUCN_PM_DEG
New ODUCn PM signal degraded. This
alarm is generated if signal
degradation occurs or the bit error
count exceeds the threshold when the
BIP8 detection is in burst mode and
generated if signal degradation occurs
when the BIP8 detection in poisson
mode.
Alarm Name Update Type Description
ODUCN_PM_SSF
New Failure of ODUCn PM server-layer
signals.
ODUCN_PM_TIM
New Mismatch of the ODUCn PM trace
identifier. This alarm is generated
during control process when the trace
identifier at the opposite end
mismatches that at the local end when
the TIM detection is enabled.
OPUCN_MSIM
New OPUCn multiplex structure identifier
mismatch.
OPUCN_PLM
New OPUCn payload mismatch. The type of
received payload mismatches the
expected payload type defined in the
adaptation function.
OTUCN_BDI
New OTUCn backward defect indication.
This alarm is generated when the SM
section detects a signal failure and the
value of the BDI byte is 1.
OTUCN_DEG
New The OTUCn_DEG is an alarm indicating
that the OTUCn signal is degraded.
When the BIP8 detection is in burst
mode, this alarm is generated if the
signal degradation or bit error count
exceeds the threshold. In addition,
when the BIP8 detection in poisson
mode, this alarm is generated if the
signal degradation exceeds the
threshold.
Alarm Name Update Type Description
OTUCN_LOF
New The OTUCN_LOF is an alarm indicating
that the frame alignment signal (FAS)
is abnormal. This alarm occurs when
the frame alignment processing is out
of frame (OOF) in three consecutive
milliseconds.
OTUCN_LOM
New The OTUCN_LOM is an alarm
indicating that the multiframe
alignment signal (MFAS) is abnormal.
This alarm occurs when the multiframe
locating is out of multiframe (OOM) in
three consecutive milliseconds.
OTUCN_SSF
New The OTUCN_SSF is an alarm that the
signal fails at the OTUCn server layer.
OTUCN_TIM
New OTUCn trail trace identifier (TTI)
mismatch. This alarm is generated
during the control process when the
TTI at the opposite end mismatches
that at the local end if the TIM
detection is enabled.
PWD_ENCRYPT_RISK
New User password encryption mode risk
alarm. This alarm is generated when a
user performs the following
operations:
CLK_LOCK_FAIL
New Clock lockout failure alarm. When the
frequency of an NE is synchronized from
the upstream, the frequency lock status is
locking. When the frequency of an NE is
not locked, this alarm is reported to
remind the user of the unlock status of
the NE clock.
CLK_NO_TRACE_MODE
New The CLK_NO_TRACE_MODE is an alarm
indicating that the clock enters the non-
tracing mode. This alarm is generated
when the current clock does not trace
Alarm Name Update Type Description
EXT_SYNC_LOS
New The EXT_SYNC_LOS is an alarm indicating
the loss of external clock source. This
alarm is generated when the system
detects the loss of the external clock
source traced by the equipment.
EXT_TIME_LOC
New The EXT_TIME_LOC is an alarm indicating
the loss of the external time source. This
alarm is generated when the board does
not detect the external timing signal after
the external timing port is enabled.
LTI
New The LTI is an alarm indicating the loss of
synchronization source. This alarm is
generated when there are clock sources
other than internal clock sources listed in
the priority table but the board operates
in the holdover or free-run mode.
OOL
New The OOL is an alarm indicating that the
phase-locked loop is out of lock. This
alarm is generated when the phase-
locked loop on the clock board becomes
faulty.
PTP_SOURCE_SWITCH
New PTP time source switching alarm. When
the ID of the Grandmaster source traced
by the NE or the tracing port changes,
this alarm is reported to remind the user
of switchover of the IEEE 1588v2 tracing
source.
Alarm Name Update Type Description
PTP_TIMESTAMP_ABN
New PTP time stamp exception. When the PTP
(IEEE 1588v2) time stamp freezes, this
alarm is reported.
S1_SYN_CHANGE
New The S1_SYN_CHANGE is an alarm
indicating that the synchronous source is
changed in the S1 mode.
SSM_LOS
New This alarm indicates that the SSM quality
information fails to be received. In SSM
mode, this alarm is reported when a
reference source port configured in the
priority table fails to obtain valid SSM
quality information within 5 seconds.
SSM_QL_FAILED
New This alarm indicates that the received
SSM quality is worse than the threshold.
This alarm is generated when the SSM
quality received by a reference source
port configured in the priority table is
worse than the threshold.
SYN_BAD
New SYN_BAD is a synchronization source
degrade alarm. This alarm is generated
when the frequency deviation of the
synchronization source exceeds the
permitted range so that quality of the
physical-layer synchronization source
deteriorates.
SYNC_C_LOS
New SYNC_C_LOS is an alarm indicating a
synchronization source priority loss. This
alarm is generated when the clock source
on a service board is lost in the priority
Alarm Name Update Type Description
table.
SYNC_F_M_SWITCH
New The SYNC_F_M_SWITCH is an alarm
indicating the forced or manual switching
state of a clock source.
SYNC_LOCKOFF
New The SYNC_LOCKOFF is an alarm
indicating that the clock source in the
priority list is locked.
SWDL_BD_MATCH_FAIL
New The SWDL_BD_MATCH_FAIL alarm
indicates a board software matching
failure. This alarm is reported if matching
the board software version to the NE
version fails during an NE upgrade or
downgrade.
TIME_LOCK_FAIL
New Time lock failure alarm. When the time of
an NE is synchronized from the upstream,
the time lock status is locking. When the
time of an NE is not locked, this alarm is
reported to remind the user of the unlock
status of the NE time.
TIME_LOS
New The TIME_LOS is an alarm indicating the
loss of the time source level. This alarm is
generated when the time source state
does not exist after the precision time
function is enabled.
TIME_NO_TRACE_MODE
New The TIME_NO_TRACE_MODE is an alarm
indicating that the time enters the non-
trace mode. The precision time of the
board is in the non-trace mode. This
Alarm Name Update Type Description
FSWIOP
New Single wave input power of amplifiers
boards.
FSWOOP
New Single wave output power of amplifiers
boards.
FSWSNL
New Single wave OSNR loss of amplifiers
boards.
FSWSNR
New Single wave OSNR of amplifiers boards.
Performance Event Update Type Description
Name
PEAK_INPOWER
New The peak input optical power.
PEAK_LSBIAS
New The peak bias current of the laser.
PEAK_LSTMP
New The peak laser temperature.
PEAK_OUTPOWER
New The peak output optical power.
VALLEY_INPOWER
New The valley input optical power.
VALLEY_LSBIAS
New The valley bias current of the laser.
VALLEY_LSTMP
New The valley laser temperature.
VALLEY_OUTPOWER
New The valley output optical power.
Q_VALUE_EER
New Value of Q data.
FSWIOP
New Single wave input power of amplifiers
Performance Event Update Type Description
Name
boards.
FSWOOP
New Single wave output power of amplifiers
boards.
FSWSNL
New Single wave OSNR loss of amplifiers
boards.
FSWSNR
New Single wave OSNR of amplifiers boards.
PEAK_INPOWER
New The peak input optical power.
PEAK_LSBIAS
New The peak bias current of the laser.
PEAK_LSTMP
New The peak laser temperature.
PEAK_OUTPOWER
New The peak output optical power.
VALLEY_INPOWER
New The valley input optical power.
VALLEY_LSBIAS
New The valley bias current of the laser.
VALLEY_LSTMP
New The valley laser temperature.
VALLEY_OUTPOWER
New The valley output optical power.
Performance Events of
Higher Order Path Bit
New Added the support for TDM services and
Errors the related performance events.
Performance Events of
Lower Order Path Bit
New Added the support for TDM services and
Errors the related performance events.
Performance Event of
Pointer Justifications
New Added the support for TDM services and
the related performance events.
OSPITMP
New Temperature in the tube core of the laser.
It includes:
CFP_LSBIAS
New Bias current of the laser on the channel of
the CFP module.
CFP_LSIOP
New Input optical power of the laser on the
channel of the CFP module.
CFP_LSOOP
New Output optical power of the laser on the
channel of the CFP module.
CFP_LSTMP
New Working temperature of the laser on the
channel of the CFP module.
CPUUSAGE
New CPU usage in one performance
measurement unit. It contains the
CPUUSAGEMAX, CPUUSAGEMIN,
CPUUSAGECUR, and CPUUSAGEAVG,
which respectively indicates the maximum
value, minimum value, current value, and
average value of the CPU usage.
MEMUSAGE
New Memory usage . It contains the
MEMUSAGEMAX, MEMUSAGEMIN,
MEMUSAGECUR, and MEMUSAGEAVG,
which respectively indicates the maximum
value, minimum value, current value, and
average value of memory usage.
CFP_LSBIAS
New Bias current of the laser on the channel of
the CFP module.
CFP_LSIOP
New Input optical power of the laser on the
channel of the CFP module.
Performance Event Update Type Description
Name
CFP_LSOOP
New Output optical power of the laser on the
channel of the CFP module.
CFP_LSTMP
New Working temperature of the laser on the
channel of the CFP module.
FREQDEV
New Frequency deviation between the current
input clock and input reference clock
source. It is an indicator of the IEEE 1588v2
performance and has no impact on
services.
MEANPATHDELAY
New Path delay between the master clock and a
slave clock. It is an indicator of the IEEE
1588v2 performance and has no impact
on services.
PHASEOFFSET
New Time deviation between the master clock
and a slave clock. It is an indicator of the
IEEE 1588v2 performance and has no
impact on services.
The signal flow of an REG node is similar to that of a back-to-back OTM node,
except that no signal is added or dropped at the REG node. Signals are regenerated
through a line board.
Figure 1 and Figure 2 show the signal flows of example 80-wavelength REG nodes.
Regeneration boards
Regeneration boards are used to directly regenerate signals.
Line boards
Line boards with the regeneration function are used to directly regenerate
signals.
Two line boards without the regeneration function are interconnected and
electrical cross-connections are configured between them to regenerate signals.
Figure 1 Signal flow of an 80-wavelength REG node (regeneration boards or line boards with
the regeneration function)
Figure 2 Signal flow of an 80-wavelength REG node (line boards without the regeneration
function)