T-MVYMX3-15,
ATC MAINTENANCE
P-3
2a
Tool Data Registration
Register the tool numbers into #8610 to #8668 (only even numbers are
used) of (gox) (dtagonosis).
DGN No.
#8610 Number of tool in the No. 1 pot
#8612 Number of tool in the No. 2 pot
#8668 Number of tool in the No. 30 pot
* The highest digit of the 4-digit tool number is 9 for the
large-diameter tool, 1 to 8 for the middle-diameter tool and 0
for the small-diameter tool.
Therefore, display setting is possible at #8608 for spindle
tool and at #7413 for empty pot data excessively.
Only dieplay te poooible at #9606 for tool on charge position.
How to register tool data
[ Set che system number(SETTING #6219) at
Press the diagnosis key
Te's built-in lamp comes on.
®
MORI SEIKI CO.,LTD.T-MVYMK3-18,
‘ATC MAINTENANCE
P-4
Qo
Call the desired parameter number by entering its four digits
via the keyboard or by means of the PAGE and CURSOR keys
To call up DGN #8610 (to register the tool number in the
No. 1 pot), push the [8], [6], [1] and [O]keys, and
(cursor) key.
Resister tool number.
To register the tool number 0001, push the [0], [0]. [0]
and [1] keys, and [WR] key.
Return the System number(SETTING #6219) to "0
T
Press the RESET key [rest
DIAGKOSIS 000 Noo00
P-NO T-X0
28610 (001) 0001
28611
28612 (002) 0002
28613
8614 (003) 0003
$8615
38616 (004) 0004
438617
#8618 (005) 0005
28619
Usk
MORI SEIKI CO.,LTD.