You are on page 1of 2
T-MVYMX3-15, ATC MAINTENANCE P-3 2a Tool Data Registration Register the tool numbers into #8610 to #8668 (only even numbers are used) of (gox) (dtagonosis). DGN No. #8610 Number of tool in the No. 1 pot #8612 Number of tool in the No. 2 pot #8668 Number of tool in the No. 30 pot * The highest digit of the 4-digit tool number is 9 for the large-diameter tool, 1 to 8 for the middle-diameter tool and 0 for the small-diameter tool. Therefore, display setting is possible at #8608 for spindle tool and at #7413 for empty pot data excessively. Only dieplay te poooible at #9606 for tool on charge position. How to register tool data [ Set che system number(SETTING #6219) at Press the diagnosis key Te's built-in lamp comes on. ® MORI SEIKI CO.,LTD. T-MVYMK3-18, ‘ATC MAINTENANCE P-4 Qo Call the desired parameter number by entering its four digits via the keyboard or by means of the PAGE and CURSOR keys To call up DGN #8610 (to register the tool number in the No. 1 pot), push the [8], [6], [1] and [O]keys, and (cursor) key. Resister tool number. To register the tool number 0001, push the [0], [0]. [0] and [1] keys, and [WR] key. Return the System number(SETTING #6219) to "0 T Press the RESET key [rest DIAGKOSIS 000 Noo00 P-NO T-X0 28610 (001) 0001 28611 28612 (002) 0002 28613 8614 (003) 0003 $8615 38616 (004) 0004 438617 #8618 (005) 0005 28619 Usk MORI SEIKI CO.,LTD.