USSV-265

ATC RECOVERY ON MV-35 ~ 55 WITH MX-2 CONTROL

Procedure A
1. Remove pin #87 as shown in the bottom drawing.
2. Select MDI mode and enter an M31, then press cycle start.
3. Key in the following steps: M87, M88, M82 then M83, and the main arm will come down.
4. Move the arm 180 degrees and turn the FLOW CONTROL valve fully CW.
5. Key in an M84, then press RESET.
6. Make the main arm parallel to the headstock.
7. Key in an M85, and the arm will move up.
8. Key in an M88, then an M86.
9. Move the arm 180 degrees to the original position.
10. Enter an M32, and replace pin #87.

Procedure B
1. Same as above.
2. Same as above.
3. Same as above.
4. Same as above.
5. Enter an M88 and press reset.
6. Same as above.
7. Same as above.
8. Same as above.
9. Enter an M86.
10. Same as above.

Filename: MV-35-55 MX-2 CONTROL ATC RECOVERY.doc Disclosure: This document is considered part of the Mori Seiki
knowledge base. This document does not contain approved information, but rather an account of an experience used successfully
in the past. Use this information with care.
USSV-265

Sequential # Operation Name ATC Step M Code


1 Orientation M19
2 Pot Down M80
3 Arm 60 deg. CCW M81
*3 Tool Lock M94 For MV-55
4 Tool Unclamp M82
5 Arm Down M83
6 Arm 180 deg. CW M84
7 Arm Up M85
8 Tool Clamp M86
*8 Tool Unlock M95 For MV-55
9 Arm 60 deg. CW M87
10 Rack Return M88
11 Pot Up M89

When tool of different sizes are assigned to the magazine, after doing step 5, you
must put the pot back up, index the magazine to a empty pot position, rotate the
arm 180 degrees by step 6, then put the pot back down before doing step 7.

Filename: MV-35-55 MX-2 CONTROL ATC RECOVERY.doc Disclosure: This document is considered part of the Mori Seiki
knowledge base. This document does not contain approved information, but rather an account of an experience used successfully
in the past. Use this information with care.