Professional Documents
Culture Documents
8.2.4-F42, REV. 2
REV DATE: 09/10/2014
Signomat (Optional)
Disengage Engage Bypass Rotation Bypass Feed Set Rotation &
Lock Lock Feed Locks
M13 M14 M15 M16 M18
Air Knife
On Off Pulse
M10 M11 M12
Dump Table
Cycle Latch Low Press Unlatch Low Latch Lift Down Unlatch Lift
Press Down
M64 M66 M67 M68 M69
Oxy Torch
Light High Pre-Heat On Cut O2 Off Torch Off
M80 M81 M82 M85
AutoGas
Find proper cut chart / set Find all cut and gas data Send data to HPR - 095/078
R74
M21 M22 M23
M56 M57 M7 M8
Plasma Torch
Set HC Light Light Pierce Enable Disable Torch Off Pre-Light
Limit from Normal Height Height with Hold
here Control Control Ignition
(HC) (HC)
M20 M60 M61 M62 M63 M65 M160
Do not use this m-code in your normal NC program. It is usually called from within a
cycle.
This m-code causes a cycle to execute.
R Description Notes
50 Current spindle tool Used when a torch is activated (T20/T21)
51 Plasma Consumable Type 0=Std, 1=Bevel, 2=TruBevel – NC cycle
52 Plasma Current (amps) (30,50,80,130,200,260,400) NC cycle
53 Plasma Gas Type See AutoGas charts - NC cycle
54 Shield Gas Type See AutoGas charts - NC cycle
55 Bevel Angle (°) NC cycle
56 Bevel Type 0=A, 1=V, 2=Y – NC cycle
57 Land (mm) Set by NC prog via cycle call
58 Position for Plasma pierce Calculated within BEVELP.SPF cycle
(mm)
59 Position for Plasma cut (mm) Calculated within BEVELP.SPF cycle
60 Material Thickness (mm) Read by vertical clamp
61 Plasma Correction Angle (°) NC prog or HT Look-up
62 Plasma Pierce Height (mm) NC prog or HT Look-up
63 Plasma Pierce Delay (s) NC prog or HT Look-up
64 Plasma Cut Height (mm) NC prog or HT Look-up
65 Preliminary Kerf (mm) NC prog or HT Look-up
66 Preliminary Feed rate NC prog or HT Look-up
(mm/min)
67 Plasma Preflow (psi) NC prog or HT Look-up
68 Shield Preflow (psi) NC prog or HT Look-up
69 Plasma Cutflow (psi) NC prog or HT Look-up
70 Shield Cutflow (psi) NC prog or HT Look-up
71 Mix Gas 1 (psi) NC prog or HT Look-up
72 Mix Gas 2 (psi) NC prog or HT Look-up
73 Arc Voltage (v) NC prog or HT Look-up
74 Base Length (mm) NC prog or HT Look-up
75 Actual Feed rate (mm/min) NC prog or HT Look-up
8 of 12
HSFDB 1800/2500C Checkout Form
8.2.4-F42, REV. 2
REV DATE: 09/10/2014
9 of 12