You are on page 1of 1

Vælg sprog / Chose language English

Calculation of wind load on duo-pitch roofs © NGH 2013

Building: xxx

Width of building b = 5,99 m


Length of building l = 17,99 m
Height of building h = 4,50 m (from terrain to ridge)

Overhang facade f = 0,35 m


Overhang gable g = 0,35 m
Roof inclination v = 30 º (from horizontal)
Self-weight roof gk = 0,60 kN/m2 (planar load)

Terrain catagory = II Area with low vegetation such as grass and isolated obstacles
(trees, buildings) with separations of at least 20 obstacle heights

Basic wind speed vo = 24 m/s Other areas in Denmark Roof dimensions

ULS: γG = 0,9 Safety factor for self-weight


γQ = 1,5 Safety factor for wind load

Width steel ties = 40 mm Roof width = 7,72 m


Steel quality = S235

Roof length = 18,69 m

Wind on facade Wind on gable


e/10 = 0,90 m e/10 = 0,60 m
e/4 = 2,25 m e/4 = 1,50 m
e/2 = 4,50 m e/2 = 3,00 m

Wind on facade (0º)

Area Numbers Sum Ed ↑ Sum Ed ↑ Anec Ties Ties in


2 2
[kN] [kN/m ] [mm ] totally each area
F 2 0,58 0,14 3 1 1 ←
G 1 1,84 0,14 9 1 1 ←
H 1 -6,55 -0,12 0 0 0
I 1 3,13 0,06 16 1 1 ←
J 1 2,42 0,14 12 1 1 ←
Sum 1,42 ≈ 0,1 ton

Wind on gable (90º)

Area Numbers Sum Ed ↑ Sum Ed ↑ Anec Ties Ties in


2 2
[kN] [kN/m ] [mm ] totally each area
F 2 1,20 0,67 6 1 1 ←
G 2 2,64 0,93 13 1 1 ←
H 2 7,51 0,41 37 1 1 ←
I 2 17,44 0,14 87 2 1 ←
Sum 28,79 ≈ 2,9 ton

You might also like