You are on page 1of 1

pq q p p

I O NA L ENG
d
h
SS

FE

IN
DEPTH OF FLOW IN CHAMBER PARAMETER

PR O

EE
R
CIVIL
S.N.VASUTAVAN
1799
SI E
NG A PO R

(QUALIFIED PERSON FOR STRUCTURAL WORKS STAMP & SIGNATURE)

p p p
REV DATE NAME SUBJECT CHK'D

° °

VASU CHARTERED ENGINEERS


6 UBI ROAD 1, WINTECH CENTRE,
#06-10
SINGAPORE 408726
TEL / FAX : 6749 0365
Email: vasuchartered@gmail.com

Using h/d value to determine mathematically the parameter [Q/d2.5]


value
DISCHARGE PARAMETER Q/d2.5
Derived equation between A and B from graphical represetation:
VORTEX DROP CHAMBER
y = -0.0014x6 + 0.0175x5 - 0.0776x4 + 0.137x3- 0.0671x2+ 0.7292x PERFORMANCE CHARACTERISTICS
where y = h/d, x = Q/d2.5 ,
and 0 ≤ x ≤4.42 (from A to B)
This information is used for in-house vortex design.

Ackknowlegdement:
This is adapted from Model Test A-14 done by
Sydney Water Board.