You are on page 1of 2

6FM90T-X

Shenzhen Center Power


12V 90Ah(10hr)
Tech.Co.Ltd,.

Overview
The rechargeable batteries are lead-lead dioxide systems. The dilute sulfuric acid electrolyte is
absorbed by separators and plates and thus immobilized. Should the battery be accidentally
overcharged producing hydrogen and oxygen, special oneway valves allow the gases to escape
thus avoiding excessive pressure build-up. Otherwise, the battery is completely sealed and is,
therefore, maintenance-free, leak proof and usable in any position.

Battery Construction
Component Positive plate Negative plate Container Cover Safety valve Terminal Separator Electrolyte
Raw material Lead dioxide Lead ABS ABS Rubber Pb Fiberglass Sulfuric acid

General Features Battery Specification


Positive and negative plates in lead-calcium-tin alloy;
Performance Characteristics
Stable Quality&High Reliability;
Nominal Voltage 12V
Sealed Construcrion;
Number of cell 6
Long Service Life;
Design Life 10 years
Maintenance-Free Operation;
Nominal Capacity 77℉(25℃)
Low Pressure Venting System; 10 hour rate (9.0A, 10.8V) 90Ah
Low Self Discharge; 5 hour rate (16.2A, 10.5V) 81.0Ah
U.L.Component Recognition; 1 hour rate (62.0A, 9.6V) 62.0Ah
Six months shelf life at 20℃; Internal Resistance
Design life 10 years Fully Charged battery 77℉(25℃) ≤5.2 mOhms
Self-Discharge
3% of capacity declined per month at 20℃(average)
Operating Temperature Range
Discharge -20~60℃
Charge -10~60℃
Storage -20~60℃
Max. Discharge Current 77℉(25℃) 800A(5s)
Dimensions and Weight Short Circuit Current 2000A
Charge Methods: Constant Voltage Charge 77℉(25℃)
Length(mm / inch) 306/12.05
Cycle use 2.30-2.35VPC
Width(mm / inch) 169/6.65
Maximum charging current 27.0A
Height(mm / inch) 210/8.27 Temperature compensation -30mV/℃
Total Height(mm / inch) 215/8.46 Standby use 2.23-2.27VPC
Approx. Weight(Kg / lbs) 29.0/63.9 Temperature compensation -20mV/℃
* Weight deviation: ± 5%
Discharge Constant Current (Amperes at 77oF25oC)
End Point
Volts/Cell 10min 15min 30min 45min 1h 3h 5h 10h
1.60V 218 173 100 74.7 62.0 27.0 17.2 9.30
1.65V 208 162 95.0 71.5 56.6 26.0 17.0 9.25
1.70V 186 153 90.0 67.9 56.0 25.1 16.7 9.18
1.75V 175 142 87.4 65.5 54.6 24.2 16.2 9.10
1.80V 163 132 84.2 63.0 52.4 23.1 15.7 9.00
o o
Discharge Constant Power (Watts at 77 F25 C)
End Point
Volts/Cell 10min 15min 30min 45min 1h 2h 3h 5h
1.60V 373 308 189 145 117 65.5 48.3 32.3
1.65V 364 303 180 139 112 64.1 48.2 31.9
1.70V 345 284 171 129 107 61.8 46.8 31.5
1.75V 343 281 167 128 103 59.8 45.4 30.7
1.80V 314 267 163 125 101 59.1 45.2 30.3

(Note)The above characteristics data are average values


obtained within three charge/discharge cycles not the mimimum
values.All data shall be changed without notice,Vision reserves
the right to explain and update the information contained hereinto.

Shenzhen Center Power Tech.Co.Ltd,. STOCK CODE: 002733 www.vision-batt.com


6FM90T-X
Shenzhen Center Power
12V 90Ah(10hr)
Tech.Co.Ltd,.

Constant Current Discharge Constant Power Discharge


1000 1000

Wattage(W)
100 100
Current(A)

10 10

1 1
1 10 100 1000 10000 1 10 100 1000 10000
1.60V 1.65V 1.70V 1.60V 1.65V 1.70V
Time/mins Time/mins
1.75V 1.80V 1.75V 1.80V

Charged

Current

Voltage
Volume
Constant voltage charging
characteristic (0.25CA,25 ℃)
(%) (XCA) (V)
12.0 140

120 0.25
15.0 Charged Volume
100 0.20
9.0 A 14.0 Charge Voltage
25.0 A 19.2 A 80
9.6 0.15
200 A 90 A 62 A 60 13.0
0.10
40 12.0
20 0.05
11.0 Charging Current
0 0
0 2 4 6 8 10 12 14 16 18 20
Charging time (hours)

Self-discharge characteristic
Relationship between
(V/CELL)
(V/12V)

charging voltage and temperature


(V/6V)
(V/8V)

(V/4V)

100

90
Capacity(%)

15.6 10.4 7.8 5.2 2.6

Cycl 80
15.0 10.0 7.5 5.0 2.5 e Us
e
14.4 9.6 7.2 4.8 2.4 70

STANDB
13.8 9.2 6.9 4.6 2.3 Y USE 60
℃ ℃ ℃
13.2 8.8 6.6 4.4 2.2 50

-10 0 10 20 30 40 50 60 40
0 2 4 6 8 10 12 14 16 18 20
Ambient temperature (℃)
Storage time: months

120
Life characteristics of Standby use Cycle service life in relation to depth of discharge
120

100 100
Capacity(%)

80 80
Capacity(%)

60 60
100% D.O.D. 50% D.O.D. 30% Depth of discharge
Testing conditions:floating voltage:2.27 to 2.30V Cell
ambient temperature: 25°C(77°F)
40
40

20
20

0 200 400 600 800 1000 1200 1400


0 1 2 3 Number of cycles(cycles)
Life(year)

Temperature effects on float life Temperature effects on capacity


120

100
C
0.05
80 0.1C
Capacity (%)
Life(years)

0.2C
60

40 1.0C
2.0C
20

0
o
-20 -10 0 10 20 30 40 50
Temperature( C) Temperature (°C )

Shenzhen Center Power Tech.Co.Ltd,. STOCK CODE: 002733 www.vision-batt.com