You are on page 1of 2

6FM200 12V 200Ah(20hr)

The rechargeable batteries are lead-lead dioxide systems. The dilute sulfuric acid
electrolyte is absorbed by separators and plates and thus immobilized. Should the
battery be accidentally overcharged producing hydrogen and oxygen, special one-
way valves allow the gases to escape thus avoiding excessive pressure build-up.
Otherwise, the battery is completely sealed and is, therefore, maintenance-free,
leak proof and usable in any position.

Battery Construction
Component Positive plate Negative plate Container Cover Safety valve Terminal Separator Electrolyte
Raw material Lead dioxide Lead ABS ABS Rubber Copper Fiberglass Sulfuric acid

General Features Performance Characteristics


● Absorbent Glass Mat (AGM) technology Nominal Voltage 12V
for efficient gas recombination of up to Number of cell 6
99% and freedom from electrolyte
Design Life 10 years
maintenance or water adding.
o
Nominal Capacity 77 F(25 C)o
● Not restricted for air transport-complies
with IATA/ICAO Special Provision A67. 20 hour rate (10A, 10.5V) 200Ah
● UL-recognized component. 10 hour rate (18.8A, 10.5V) 188Ah
● Can be mounted in any orientation. 5 hour rate (35.6A, 10.5V) 178Ah
● Computer designed lead, calcium tin alloy 1 hour rate (134A, 9.6V) 134Ah
grid for high power density. Internal Resistance
● Long service life, float or cyclic Fully Charged battery 77oF(25oC) 3.5mOhms
applications. Self-Discharge
● Maintenance-free operation. 3% of capacity declined per month at 20oC(average)
● Low self discharge.
Operating Temperature Range
Discharge -20~60oC
Dimensions and Weight Charge -10~60oC
Storage -20~60oC
Length(mm / inch) 522 / 20.55 o o
Max. Discharge Current 77 F(25 C) 1000A(5s)
Width(mm / inch) 238 / 9.37
Height(mm / inch) 218 / 8.58 Short Circuit Current 3300A
Total Height(mm / inch) 240 / 9.45 Charge Methods: Constant Voltage Charge 77oF(25oC)
Approx. Weight(Kg / lbs) 65 / 143.3 Cycle use 14.4-14.7V
Maximum charging current 60A
Temperature compensation -30mV/oC
Standby use 13.6-13.8V
Temperature compensation -20mV/oC

Discharge Constant Current (Amperes at 77oF25oC)


End Point
10min 15min 30min 1h 3h 5h 10h 20h
Volts/Cell
1.60V 422 344 204 134 51.6 37.8 20.0 10.40
1.65V 397 324 196 131 50.4 37.1 19.6 10.30
1.70V 374 303 189 128 49.4 36.3 19.2 10.10
1.75V 349 283 182 125 48.3 35.6 18.8 10.00
1.80V 321 263 175 122 46.9 34.8 18.3 9.84

Discharge Constant Power (Watts at 77oF25oC)


End Point
10min 15min 30min 45min 1h 2h 3h 5h
Volts/Cell
1.60V 737 596 390 279 258 141 99.9 72.1
1.65V 701 576 375 273 253 138 98.6 71.5
1.70V 664 558 361 268 248 135 97.2 70.9
1.75V 625 539 346 262 243 132 95.8 70.4
1.80V 594 507 332 257 238 128 94.8 69.8
(Note)The above characteristics data are average values obtained within
three charge/discharge cycles not the mimimum values.

page1 of 2 www.vision-batt.com
6FM200 12V 200Ah

Charged
Discharge characteristic (25 OC)

Current

Voltage
Volume
Constant voltage charging
o
characteristic (0.25CA,25 C)
13.0
(%) (XCA) (V)
12.0
140

120 0.25
15.0
Voltage(v)

11.0 CHARGED VOLUME


100 0.20
14.0 CHARGE VOLTAGE
10.0
80
0.15
13.0
9.0 60
0.10
40 12.0
8.0
20 0.05
11.0 CHARGING CURRENT
0
0 1 2 3 5 10 20 30 60 2 3 5 10 20 30 0 0
min h 0 2 4 6 8 10 12 14 16 18 20
Discharge time Charging time (hours)

Relationship between Self-discharge characteristic


charging voltage and temperature
110
(V/12V)

(V/CELL)
(V/6V)
(V/8V)

(V/4V)

100

90

Capacity(%)
15.6 10.4 7.8 5.2 2.6
80
15.0 10.0 7.5 5.0 2.5

9.6
70
14.4 7.2 4.8 2.4

13.8 9.2 6.9 4.6 2.3 60

13.2 8.8 6.6 4.4 2.2 50

-10 0 10 20 30 40 50 60
40
0 2 4 6 8 10 12 14 16 18 20
Ambient temperature( oC) Storage time: months

Cycle service life in relation to


Life characteristics of Standby use
120 depth of discharge
120

100
100
Capacity(%)

80
Capacity(%)

80

60
60 30% Depth of discharge

40 40

20 20

0 0 200 400 600 800 1000 1200 1400


4 6 8
Life(year) Number of cycles(cycles)

Temperature effects on float life Temperature effects on capacity


15
120

100
Life(years)

10
Capacity (%)

80

60
5

40

20

0 0
10 20 30 40 50
o
-20 -10 0 10 20 30 40 50( C)
o
Temperature( C)

THE INTERNATIONAL CERTIFICATION NETWORK

MH25860 G4M19906-9202-E-16
ISO9001:2000

Shenzhen Center Power Tech. Co., Ltd. www.vision-batt.com


Center Power Industrial Park, Tongfu Industrial District Dapeng Town, 518120 Shenzhen, China
Tel: (+86-755) 8431 8088 Fax: (+86-755) 8431 8038 E-mail: sales@vision-batt.com

Copy Right Shenzhen Center Power Technology Co., Ltd (Edition 2003-9)

Page 2 of 2

You might also like