You are on page 1of 2

6FM200D-X 12V 200Ah(20hr)

The rechargeable batteries are lead-lead dioxide systems. The dilute sulfuric acid
electrolyte is absorbed by separators and plates and thus immobilized. Should the
battery be accidentally overcharged producing hydrogen and oxygen, special one-
way valves allow the gases to escape thus avoiding excessive pressure build-up.
Otherwise, the battery is completely sealed and is, therefore, maintenance-free,
leak proof and usable in any position.

Battery Construction
Component Positive plate Negative plate Container Cover Safety valve Terminal Separator Electrolyte
Raw material Lead dioxide Lead ABS ABS Rubber Copper Fiberglass Sulfuric acid

General Features Performance Characteristics


● Absorbent Glass Mat (AGM) technology Nominal Voltage 12V
for efficient gas recombination of up to Number of cell 6
99% and freedom from electrolyte Design Life 10 years
maintenance or water adding. Nominal Capacity 77oF(25oC)
● Not restricted for air transport-complies
20 hour rate (18.7A, 10.8V) 200Ah
with IATA/ICAO Special Provision A67.
10 hour rate (18.7A, 10.8V) 187Ah
● UL-recognized component.
● Can be mounted in any orientation. 5 hour rate (35.8A, 10.5V) 179Ah
● Computer designed lead, calcium tin alloy 1 hour rate (126A, 9.6V) 126Ah
grid for high power density. Internal Resistance
● Long service life, float or cyclic Fully Charged battery 77oF(25oC) 3.5mOhms
applications. Self-Discharge
● Maintenance-free operation. 3% of capacity declined per month at 20oC(average)
● Low self discharge.
Operating Temperature Range
Discharge -20~60oC
Dimensions and Weight Charge -10~60oC
Storage -20~60oC
Length(mm / inch) 522 / 20.55 o o
Max. Discharge Current 77 F(25 C) 1000A(5s)
Width(mm / inch) 238 / 9.37
Height(mm / inch) 218 / 8.58 Short Circuit Current 3300A
Total Height(mm / inch) 223 / 8.78 Charge Methods: Constant Voltage Charge 77oF(25oC)
Approx. Weight(Kg / lbs) 65 / 143.3 Cycle use 14.4-14.7V
Maximum charging current 60A
Temperature compensation -30mV/oC
Standby use 13.6-13.8V
Temperature compensation -20mV/oC

Discharge Constant Current (Amperes at 77oF25oC)


End Point
5min 10min 15min 30min 45min 1h 3h 5h 10h 20h
Volts/Cell
1.60V 537 423 350 215 156 126 57.0 38.0 19.1 10.8
1.65V 489 403 340 207 150 122 55.0 37.0 19.0 10.6
1.70V 459 385 327 201 146 118 54.5 36.4 18.9 10.4
1.75V 439 367 310 195 142 115 52.9 35.8 18.8 10.2
1.80V 408 318 261 182 137 112 50.5 35.2 18.7 10.0

Discharge Constant Power (Watts at 77oF25oC)


End Point
5min 10min 15min 30min 45min 1h 2h 3h 5h
Volts/Cell
1.60V 876 727 607 392 288 227 137 108 72.6
1.65V 856 701 586 380 280 222 135 106 71.6
1.70V 816 677 569 373 274 218 132 104 70.8
1.75V 774 653 561 363 269 214 128 100 69.9
1.80V 737 619 538 355 265 212 125 97.0 69.0

(Note)The above characteristics data are average values obtained within


three charge/discharge cycles not the mimimum values.

page1 of 2 www.vision-batt.com
6FM200D-X 12V200Ah
O
Discharge characteristic (25 C)

Charged

Voltage
Current
Volume
Charge characteristic curve
Constant voltage charge characteristic
(%) (XCA) (V) (0.25CA,25 oC)
12.0
140
Battery voltage(V)

120 0.25
15.0 CHARGED VOLUME
18.7A 100 0.20
52.9A 35.8A 14.0 CHARGE VOLTAGE
9.6 80
400A 200A 126A 0.15
13.0
60
0.10
40 12.0
0
1 2 3 5 10 20 30 60 2 3 5 10 20 20 0.05
11.0 CHARGING CURRENT
min h
0 0
Discharge time 0 2 4 6 8 10 12 14 16 18 20
Charging time (hours)

Relationship between
Self-discharge characteristic
charging voltage and temperature
(V/12V)

(V/CELL)
(V/8V)

(V/6V)

(V/4V)

110

100

15.6 10.4 7.8 5.2 2.6 90

Capacity(%)
CY
15.0 10.0 7.5 5.0 2.5 CL 80
EU
SE
14.4 9.6 7.2 4.8 2.4 70
S TA
ND B
Y US 60
13.8 9.2 6.9 4.6 2.3 E
40 oC 30 o C 20 o C
13.2 8.8 6.6 4.4 2.2 50

40
-10 0 10 20 30 40 50 60 0 2 4 6 8 10 12 14 16 18 20
Ambient temperature( oC) Storage time: months

Cycle service life in relation to


Life characteristics of standby use
120
depth of discharge
120

100
100
Capacity(%)

80
Capacity(%)

80

60 60
Testing conditions: floating voltage: 2.27 to 2.30V/Cell 100% D.O.D. 50% D.O.D. 30% Depth of discharge
o o
ambient temperature: 25 C(77 F)
40 40

20 20

0 0 200 400 600 800 1000 1200 1400 1600


0 4 6 8
Life(year) Number of cycles(cycles)

Temperature effects on float life Temperature effects on capacity


15 120

100
C
0 .0 5
2.30V/Cell 0 .1 C
10
Life(years)

80
Capacity (%)

0 .2 C
60
5

40 1.0C
2.0C
20

0 0
10 20 30 40 50 -20 -10 0 10 20 30 40 50
Temperature( o C) Temperature( oC)

THE INTERNATIONAL CERTIFICATION NETWORK

MH25860 G4M19906-9202-E-16
ISO9001:2000

Shenzhen Center Power Tech. Co., Ltd. www.vision-batt.com


Center Power Industrial Park, Tongfu Industrial District Dapeng Town, 518120 Shenzhen, China
Tel: (+86-755) 8431 8088 Fax: (+86-755) 8431 8038 E-mail: sales@vision-batt.com

Copy Right Shenzhen Center Power Technology Co., Ltd (Edition 2011-3)

Page 2 of 2