SK900 Web Monitoring Module User's Manual

1. Product Introduction
SK900 web monitoring module design with RJ45 Ethernet port and 4G Modem, built-in
WEB server. By connecting it with MU of Fiber optical repeater, the Fiber optical repeater can
realize local or remote WEB monitoring through Ethernet or 4G network.
This device supports Google Chrome, IE and Edge browsers. It is recommended to use
Google Chrome browser.
Product picture:

Host and accessories diagram


① :SK900 WEB Module
② :RJ45 Network Cable
③ :220V to DC12V2A Power Adapter
④ :Antenna, 11 cm long, gain 3 dbi
⑤ :RS232 serial data line

Face-plate
Indicator lights illustration:
POWER: Green, the power indicator light. Keep bright: device on; Extinguish: device off.
-1-
RX4G: Yellow, the WEB Module MCU and 4G Receiving Communication Indicator Light. When
there has data communication is bright, when no data communication is extinguished.
RXMU: Yellow, the WEB Module MCU and MU Receiving Communication Indicator Light.
When there has data communication is bright, when no data communication is extinguished.
TX4G: Green, the WEB Module MCU and 4G Module Send Communication Indicator Light.
When there has data communication is bright, when no data communication is extinguished.
TXMU: Green, the WEB Module MCU and MU send Communication Indicator Light. When
there has data communication is bright, when no data communication is extinguished.
RUN: Green, device running light. Scintillation: WEB module is running normally.
STATUS: Yellow, WEB terminal requests communication Indicator light. When PC sends data to
WEB module, it is bright, and it is extinguished when there is no request.
4G NET: Red, 4G network indicator light. Definition as follows:
4G NET Light status 4G Module network status
Keep bright Searching network, or in process of a call (including VOLTE and
SRLTE)
200ms bright, 200ms In data transmission; 4G network registered
extinguished
800ms bright, 800ms 2G/3G network registered
extinguished
Extinguished Power off or sleep mode

Left side

Front side

Back side
Interface illustration:
DC IN: Power supply interface, interface specification: 5.5*2.5, input voltage range: DC12-15V,
current greater than or equal to 2A.

-2-
RS232: Use the RS232 serial line in the accessories to connect with the RS232 interface on the
MU panel and communicates with the MU to realize the monitoring of the MU. In addition to
the communication function, this interface can also supply power to SK900 from the spare
batteries of MU. When DC IN interface has no power input, MU will supply power to SK900
through this interface. Note: When using DC IN interface normally, it is better to connect the
power supply required by the above specifications.
ANTENNA: To connect with 4 G antenna, see accessories of device.
SIMCARD: Insert mobile phone SIM card, through this mobile phone SIM card, the device can
send short messages, dial into 4G network, connect VPN server and send E-mail. If no SIM
card is inserted, the device System page will prompt "Information: Error: Initialize modem
device error".
Supports GSM850 MHz, 900 MHz, 1800 MHz and1900 MHz; WCDMA bands B1, B2, B5 and B8.
Supported LTE band: LTE FDD B1, FDD B2, FDD B3, FDD B4, FDD B5, FDD B7, FDD B8, FDD B28,
and TDD B40
Supported Category band: CAT4
ETH: RJ45 interface, it is used for local PC connection to achieve local monitoring, or access
switchboard and other devices to connect to remote PC to achieve remote monitoring. The IP
network segment factory setting is: 192.168.6.120/24.
Computer IP should also be set to this network segment: 192.168.6.X/24.
USB: The four USB interfaces do not need to be connected.
Overall Dimension Diagram:

2. Instructions

2.1. Local monitoring connection and PC parameter setting


Step 1: Turn off the MU power supply, use the RS232 data lines in accessories to connect
the SK900 module with MU, connected the SK900 module power supply, and then turned on
the MU power supply. Connect the RJ45 interface of SK900 with the RJ45 interface of PC by
network cable.
-3-
Step 2: Set the IP address of the PC.
Select the “Network neighborhood” on the computer desktop, right-click and select
Properties.

Select “Local Connection”, right-click and select Properties.

In the pop-up dialog box, select “Internet Protocol (TCP/IP)”, click Properties.

Set the IP address of computer.

-4-
After setting up, observe whether the wired network icon of the right foot of the
computer has been connected. If there is no connection, check whether the network cable is
correctly connected or whether the network interface is damaged.
Enter the IP address of SK900 in the computer browser: 192.168.6.120 (The IP address is
shown in the label on the device), and log on to the WEB monitoring homepage. (Recommend
using Google Chrome browser).

2.2. Login Page introduction

The initial username/password is: admin/1.


You can log in by pressing the Enter key or clicking the Login button after entering the
password. It will log out if there is no operation for 15 minutes after login. After login, if close
browser without logging out, reopen the browser and enter the IP address it will skip the login
page and log in directly.
-5-
The Exit icon in the upper right corner is the logout button.

2.3 System Home page introduction

2.3.1 Prompt Content instructions


Site Information: Display whether the device is online (Online or Offline);
No. : Site number read from MU device;
4G: XXX.XXX.XXX.XXX : Display the IP address of 4G module after successful connection.
VPN: XXX.XXX.XXX.XXX: Display the IP address of VPN after successful connection.
If the VPN server IP address, UserName and PassWord are not set on the Communication page,
the 4G IP and VPN IP will not be displayed here.
Information: Display some error or prompt information.

-6-
2.3.2 Device detailed information

Site Name: The name of the site.


Sim Card Number: The SIM Card Number of Mobile Phone.
RU Number: The number of RU automatically detected by the device, read-only.
Site IP Address: The IP address of the site.
Build Time: The date and time of the site establishment.
Site Describe: The description of site, you can fill in some overview of the site here.
MU Address: Installation address of device MU.
RU1 Address: Installation address of device RU1.
RU2 Address: Installation address of device RU2.
RU3 Address: Installation address of device RU3.
RU4 Address: Installation address of device RU4.

2.3.3 Operation buttons instructions


Edit and Save buttons, can edit and save the information show in 2.3.2.

2.3.4 MU,RU1-RU4 Status instruction

MU:

RU1-4:
If MU is gray indicates that the Monitorweb device does not inquired the MU or RU, and the
Monitorweb can not communicate with the MU at this time.
If RU is grey, the communication connection between RU and MU is faulty or RU is not
energized, as follows:

If MU/RU is green, indicates that the device is online and in normal condition, as follows:

If MU/RU is red, indicates that the device is online and in alarm status, as follows:

-7-
2.4. System Parameter Page Introduction
Double-click on the connected device icon on the System homepage will enter the
System parameters page.
On left side shows the statues of MU, RU1, RU2, RU3 and RU4.
Icon Gray indicates that SK900 has not inquired this MU or RU; green indicates that the
device is online and in normal status; red indicates that the device is online and in alarm
status.
The parameters are displayed on the right side.

The parameter header with # indicates that the column is editable.

-8-
1) Device information

This page can query Device Model, Device Serial Number and Control Unit Software
Version.

-9-
2) Network parameter

This page can query and set the Site Number and Site Device Number.

- 10 -
3) Working parameter

Downlink Input Power Query (Note: Query MU):


Select the 2100M/2600M MIMO1/MIMO2 DL Input Power check box and then click the
Query button to return the downlink input power value within 30 seconds. The value should
be between -10 and 10. If it is less than -10, there may be a problem with the coupler
connection or the parameters of the coupler are incorrect. Please exclude this problem.

This page can query DL PA Temperature, Input Power, DL Output Power, PA VSWR, Optical
Chain MIMO1/MIMO2 Laser TX Power, Optical Chain MIMO1/MIMO2 Laser RX Power, MIMO1
- 11 -
Port VSWR, MIMO2 Port VSWR, DC Module1 Output Voltage, DC Module2 Output Voltage and
Monitor’s Battery Voltage.
Monitor downlink output power (Note: Query RU):
First, select one of the RU, as shown in the following figure:

Then select four 2X00 MIMOX DL Output Power check boxes on the "Working parameter"
tab and click the "Query" button. The query results should be returned within 30 seconds. The
unit of query result is: dBm.

Points for attention:


Fiber optical repeater has its own power detection function, which does not require the
testing of spectrometers and other instruments. Downlink input/output power is actually
detected value. Because the uplink output power is very small and burst signal, it can not be
detected generally. So the uplink output power value queried may be an uncertain value.

- 12 -
4) Alarm Parameter

Alarm Status: Display as Normal or Alarm.


Alarm Severity#: There are three levels of alarm severity to choose from, namely None, Low
and High. When alarm occurs, the cell background of Alarm Status is normal color, yellow and
red, respectively.
Enable Set#: Displays whether alarms are allowed.
Email#: Refers to the address of the copier (There is a addressee address in the configuration)
or the addressee address when sending an email; you can use the English comma "," to
separate multiple EMAIL addresses, the quantity is less than or equal to 10.
SMS#: It refers to the number of mobile phone sending text messages, which can use the
English comma "," to separate multiple mobile phone numbers, the quantity is less than or
equal to 10.
5) Parameter settings

- 13 -
6) Button function introduction:

Monitor List Query: Monitoring parameter query (used in the first query after the site was
built), then try not to click it. If clicked, many of the parameters set will be reset to the default
value (Contains Alarm Severity setting, email addresses and mobile phone number settings for
each alarm item).
Select all: Select all parameters
Cancel: Deselected
Clear: Clear query column value
Query: Query selected items
Set: Set selected items
All enable: Check box, it can quickly enable and disable all items on the current page. After
selection, you need to click the Set key to set them up successfully.

2.5. Entry Management Page Introduction

The parameter with * indicates that it must be filled in.


User Management: It is User list.
UserName*: It is User name of login page;
Password*: It is password of login page;
PopeName*: It can be Administrator, Operator or Read-only user;
Read-only user: Indicates that equipment parameters can only be queried not set.
Operator: It can perform operations except User Management and alarm daily record
deletion.
Administrator: All operations can be performed (maximum privileges).

- 14 -
2.6. Communication Page Introduction

Note: The item with "!" after the parameter name indicates that the device will be restarted
automatically immediately after the settings are changed.
Reboot: Manual reboot device;
DateTime Synchronization: Synchronize date and time;
Reload: Reload the Communication page parameters;

Set: Set the selected parameters;


Select all: Select all the parameters of this column;
Cancel: Deselect all the parameters of this column.

Device Serial Port!: SK900 serial port number, default is 2;


USB Device Select!: 1 means that the device uses USB port, 0 means that it does not use USB
port, default is 0;
Device Serial Bandrate!: The baud rate of serial port, default is 9600.
IP address (CIDR)!: The IP address of SK900 Ethernet port, adopts CIDR format, default is
192.168.6.120/24;
Gateway!: Network port gateway, such as 192.168.6.1, default is blank.
VPN setting:
VPN Server!: Format as: 117.88.179.12;
VPN User Name!: Format as: user9;
VPN password!: Format as: guest123;
VPN IP address (CIDR)!: Format as: 192.168.105.182 /24; It can be set as blank and
assigned IP address by VPN server. The system only supports PPTP VPN (PPTP encryption
- 15 -
mode), which is supported by general VPN devices.
If VPN IP address is blank, means that VPN client IP is assigned by the VPN server.

Email setting:

Email Address (Mail from)!:Email address of sender when sending alarm mail, format as:
user22@163.com.
SMTP Server and Port (Server:Port)!: Sender’s mail server address, format as: smtp.163.com.
The server can use Server: Port format, such as: smtp://x.x.x.x:8025.
SMTP authorization user!: User name of sender, format as: gchen
SMTP authorization password!: Password of sender, format as: Abc2
Report EMail Addresses (Mail to): Format as: test222@qq.com, support SMTP protocol.
Report EMail Addresses is the addresses of all alarm messages email, only one can be set. If
this is configured, all alarms will be copied to this mailbox. If this item is empty, it will only be
sent to the mailing list set in the alarm item.

SMS Setting:

SMS Alarm number: Mobile phone numbers to receive MU, RU1, RU2, RU3 and RU4 active
alarm messages, all active alarms will send to this number. The format can be TEXT or DATA.
SMS Report Type: It can be TEXT or DATA.
When using TEXT format, the content of short message is in common text format, and users
can understand it. Such as: “Pudong RU1 2600M MIMO2 DL Output Power Low Alarm”.
When using DATA format, the content of short message is in binary protocol text format,
which is mainly used in report center. Such as:
”!0100000000000130800101FF044101010426030104270301042A0301042B0301042C03010
42D0301042E03010465030104670301047503013F65!”.
Report Center IP Address:
Here can't be edited, just reserve a place, there is no such function.

- 16 -
2. 7. Log Page Introduction

Download Excel Report: Download LOG diary, in CSV format.


Clear Log: Clear LOG diary.
Update Program: Upload upgrade program files.