You are on page 1of 2

Global

Intrima
Bulletin
AUTHORIZED GAS TESTER LEVEL I
OPITO STANDARD
NO. 007/2019

uthorized Gas Tester (AGT) is an expert accident in a colleague who is in a work room and can

A activity intended for places have gas


hazards. There are 4 types of gas considered
dangerous according to the OPITO (Offshore
consider the oxygen level have enough to evacuate
himself and his colleagues. AGT level 1 officers must
also have a portable gas detector placed in their pocket
Petroleum Industry Training Organization), which is to detect the presence of toxic gases and oxygen levels.
explosive gases, flammable gases, liquefied gases, The lowest and safest oxygen level for AGT level 1
toxic gases. Officer who have been declared officers is 19.5% for 1 hour.
competent in an Authorized Gas Tester level 1 must
be able to analyze directly or indirectly the level and/
or content of hazardous gas in working environment.

AGT Level. Authorized Gas Tester have 3 levels


namely, AGT level 1 must have the ability to analyze
flammable and explosive gases, toxic gases, oxygen
levels and be able to work in confined spaces. AGT
level 2 must have the ability to analyze flammable and
explosive gases in preparation for the worker of hot
work permit and capable of understanding
information on hot permit. AGT level 3 must have the
ability to supervise ongoing activities or conduct
supervision in the work environment related to gas.

AGT Level 1 Duty. Officers taking the Level 1


Authorized Gas Tester education will learn more
about oxygen levels, toxic gas content, explosive and Fig. 1. Table of oxygen level effect on human body
flammable gas content, and how to work in confined
spaces. The AGT Level 1 officer will face the danger of AGT Level 1 Equipment. The completeness of AGT level
being exposed directly to his workplace to analyze the 1 officers at work is Work Permit, Portable Gas
gas content in confined space. Authorized Gas Tester Detector, SCBA (Self Contained Breathing Apparatus),
level 1 will analyze and provide reports directly to AGT PPE (Personal Protective Equipment). The duration of
level 3 officers and supervisors appointed by the HSE work of an AGT level 1 officer depends on the area to
work area officer in accordance with the permit be analyzed and the availability of oxygen carried. SCBA
designation. is not recommended for long-term use because SCBA
has a very limited time, so that the use of SCBA is only
AGT Level 1 Requirements. Authorized Gas Tester for limited analysis and for evacuating victims. In
level 1 officer must have a clear work permit and be addition to knowledge of the use of SCBA, AGT level 1
issued directly by the workplace HSE officer and work officers were also given knowledge about the use of
according to the work stated on the permit. Officers EEBD (Emergency Escape Breathing Devices). EEBD is
may initiate when carrying out a task if there is a work used only for quick emergency evacuation at work,
.
PT. Global Intrima
www.global-intrima.com
+62 21 4290 0128
solutions@global-intrima.com
AUTHORIZED GAS TESTER LEVEL 1
OPITO STANDARD
because the oxygen capacity in EEBD is less than AGT Level 1 Legality. The OPITO Certificate for
SCBA. Authorized Gas Tester is valid for up to 3 years, so
officers must conduct a competency test again at the
Calculation of usage time limit in SCBA is:
Competency Test Place (TUK) registered with the
Volume tube (liter) x pressure tube (bar) national certification institution or BNSP (Badan
-------------------------------------------------------- : Nasional Sertifikasi Profesi) to get license. There are 2
40 minute (air requirements for working hard) tests to get a license from BNSP, interview test and
written test. In interview test, officer must be answer
the question from assessor orally, practice to use a
Example : information in the name tag SCBA tube is 9
SCBA, EEBD, and Gas Detector. In written test, officer
liter 300 bar. So calculation usage time limit for SCBA
must be answer the question from assessor in writing
is
to explain, describe, and tell a story in the real case at
9 liter x 300 bar workplace.
------------------------ : = 67.5 minutes
Reference:
40 minutes Manaf, Irwansyah. Refreshment Training for Authorized
Gas Tester Module. Training Module. Jakarta : 2018

The optimal time to use SCBA is time limit SCBA


reduced by 10 minutes for the time before wearing
the equipment and 10 minutes for the backup time.
So optimal time for SCBA 9 liter 300 bar is only 47.5
minutes on work.

Fig. 2. Example of using SCBA in confined space

Disclaimer
This article has been compiled in good faith to the best of our knowledge and ability for the purpose of risk management
interest. However, Global Intrima, PT hereby disclaims any responsibility whatsoever for any error or omission contained herein
or for any damage or liability howsoever caused, arising from the use of this article of the information it contains by any party
whatsoever.

PT. Global Intrima


www.global-intrima.com
+62 21 4290 0128
solutions@global-intrima.com

You might also like