Basic loading data (for a single anchor): HIT-RE 500 with rebar section
All data on this section applies to For detailed method, see page 233– 238.
• concrete: See table below.
• correct setting (See setting operations page 232)
• no edge distance, spacing and other influences
non-cracked concrete
230
HIT-RE 500 injection adhesive with rebar
Setting details
hnom
d0
/d
0
h1
hmin
Temprature of the Working time in which rebar Curing time before rebar can
basematerial: can be inserted and adjusted be fully loaded
40°C 12 min. 4 hours
30°C 20 min. 8 hours
20°C 30 min. 12 hours
10°C 2 hours 24 hours
0°C 3 hours 50 hours
-5°C 4 hours 72 hours
less than -5°C “not allowed”
The foil pack temperature must be at least +5°C.
Installation equipment
• appropriate drill bit (diamond core bit)
• dispenser (MD 2000, BD 2000, P3000 F, P5000 HY, HIT P-8000 D)
• blow-out pump
• cleaning brushes
230
HIT-RE 500 injection adhesive with rebar
Setting operations
232
HIT-RE 500 injection adhesive with rebar
Rebar ∅ [mm] ∅8 ∅ 10 ∅ 12 ∅ 14 ∅ 16 ∅ 20 ∅ 25 ∅ 28 ∅ 32 ∅ 36 ∅ 40
∅ [mm] Nominal rebar diameter 8 10 12 14 16 20 25 28 32 36 40
As [mm²] Stressed cross-section 50.3 78.5 113.1 153.9 201.1 314.2 490.9 615.8 804.2 1017.9 1256.6
Nominal tensile
fuk [N/mm²] 550
strength
fyk [N/mm²] Yield strength 500
Caution: In view of the high loads transferable with HIT-RE 500, it must be verified by the user that the load
acting on the concrete structure, including the loads introduced by the anchor fastening, do not
cause failure, e.g. cracking, of the concrete structure.
TENSION Nrec,c/s
233
HIT-RE 500 injection adhesive with rebar
hact
fT = Limits to actual anchorage, hact: hnom ≤ hact ≤2.0 hnom
hnom
234
HIT-RE 500 injection adhesive with rebar
Anchor setting: The Hilti HIT-RE 500 bond strength reduces when the anchor is set, cures and in service in a
base material temperature range from –5 to +5°C. Hilti HIT-RE 500 adhesive shows a post curing effect. When
the adhesive warms up to above +5°C, the bond will reach its full performance.
Service life: Base material temperatures above 50°C will lead to a decrease in Hilti HIT-RE 500 bond strength.
Note:
In case of an anchor fastening, which is made in base material at a temperature below +5°C and in service at a
temperature over 50°C, only one influencing factor of the lower value should be applied.
f W.sat = 0.7
Note:
The reduction shall only be applied, if the anchor is setted into water-saturated concrete, e.g. concrete members
in water, filled water tanks, predrilled holes filled with water for more than 3 days. The reduction does not apply,
if the concrete is subjected to short term water influence, e.g. diamond-cored holes.
235
HIT-RE 500 injection adhesive with rebar
Rebar ∅ [mm] Ø8 Ø10 Ø12 Ø14 Ø16 Ø20 Ø25 Ø28 Ø32 Ø36 Ø40
1)
NRd,s [kN] 20.9 32.7 47.1 64.1 83.8 130.9 204.5 256.6 335.1 424.1 523.6
1)
The design tensile resistance is calculated from the characteristic tensile resistance, NRk,s , by NRd,s= As ⋅ fuk/γMs,N, where the partial safety
factor, γMs,N , for rebar sections, type BSt 500, is 1.32.
Combined loading: Only if tensile load and shear load applied (See page 32 and section 4 “Examples”).
0
VRd,c = VRd,c ⋅ f B,V ⋅ f AR,V ⋅ f β,V
Rebar ∅ [mm] Ø8 Ø10 Ø12 Ø14 Ø16 Ø20 Ø25 Ø28 Ø32 Ø36 Ø40
o 1)
V Rd,c [kN] 2.0 3.6 5.0 7.1 7.3 12.5 18.8 30.2 37.7 45.0 54.0
cmin [mm] Min. edge distance 40 45 55 65 65 85 105 135 150 165 180
1) o o o
The design shear resistance is calculated from the characteristic shear resistance, V Rk,c , by V Rd,c =V Rk,c /γMc,V, where the partial
safety factor, γMc,V , is 1.5.
236
HIT-RE 500 injection adhesive with rebar
fB,V: Influence of concrete strength
Concrete strength Cylinder compressive Cube compressive
designation strength, strength,
(ENV 206) fck,cyl [N/mm²] fck,cube [N/mm²] fB,V fck,cube
fB,V =
C20/25 20 25 1 25
C25/30 25 30 1.1
C30/37 30 37 1.22
C35/45 35 45 1.34 Limits:
C40/50 40 50 1.41 25 N/mm2 ≤ fck,cube ≤ 60 N/mm2
C45/55 45 55 1.48
C50/60 50 60 1.55
Concrete cylinder: Concrete cube:
Height 30cm, side length 15 cm
Diameter 15cm
Concrete test specimen geometry
237
HIT-RE 500 injection adhesive with rebar
fAR,V: Influence of edge distance and spacing
c c
f AR,V = ⋅
c min c min results c 2,1
tabulated s n-1
Formula for two-anchors fastening (edge plus below
1 spacing) only valid for s < 3c s3
s2
3⋅c + s c s1
f AR,V = ⋅ c 2 ,2 c
6 ⋅ c min c min
3 ⋅ c + s1 + s 2 + ... + sn −1 c
fAR, V = ⋅ Note: It is assumed that only the row of anchors closest to
3 ⋅ n ⋅ c min c min
the free concrete edge carries the centric shear load.
Rebar ∅ [mm] Ø8 Ø10 Ø12 Ø14 Ø16 Ø20 Ø25 Ø28 Ø32 Ø36 Ø40
1)
VRd,s [kN] 11.1 17.3 24.9 33.9 44.3 69.3 108.0 135.3 176.7 237.3 276.4
1)
The steel design shear resistance is calculated from VRd,s= (0,6⋅As⋅fuk)/γMs,V. The partial safety factor, γMs,V , for rebar sections, type BSt
500, is 1.5.
Combined loading: Only if tensile load and shear load applied (See page 32 and section 4 “Examples”).
238