You are on page 1of 4

S-CONCRETE Version 7.

02
© Copyright 2006 by Softek Services Ltd.

S-CONCRETE 7.02 Summary


(c) Softek Services Ltd. Status Warning
Maximum 1.000
Section Name Consultant V (shear) Util 0.391
Concrete Section diab N vs M Util 0.847

American Building Standards


ACI 318-05, "Building Code Requirements for Structural Concrete"
ACI 318R-05, "Commentary for ACI 318-05"

Design Aids, Manuals, and Handbooks


Notes on ACI 318-02, Portland Cement Association 2002
"ACI Detailing Manual - 1994", ACI Committee 315, American Concrete Institute, 1994
"CRSI Handbook", Concrete Reinforcing Steel Institute, 1992

Section Dimensions Material Properties Gross Properties Effective Properties


I-Shape fc' = 40 MPa Zbar = 0 mm Ae = 900000 mm2
L1 = 3000 mm fy (vert) = 420.0 MPa Ybar = 0 mm Ie (y-y) = 6750.0xE6 mm4
T1 = 300 mm fy (horz) = 420.0 MPa Ag = 900000 mm2 Ie (z-z) = 675000xE6 mm4
Wc = 2403 kg/m3 Ig (y-y) = 6750.0xE6 mm4 Ase (Y) = 600000 mm2
Ws = 8009 kg/m3 Ig (z-z) = 675000xE6 mm4 Ase (Z) = 600000 mm2
Poisson's Ratio = 0.2 Ashear (Y) = 600000 mm2 Je = 25298xE6 mm4
hagg = 19 mm Ashear (Z) = 600000 mm2
Es = 199948 MPa Jg = 25298xE6 mm4
Quantities (approx.) Ec = 31838 MPa
Concrete = 2144 kg/m Gc = 13266 MPa
Steel = 91 kg/m fr = 3.94 MPa

Panel 1 Zone A Zone B


6?16 @ 406 V.E.F 10?20 Vert 10?20 Vert
?16 @ 406 H.E.F. ?10 Ties @ 406 mm ?10 Ties @ 406 mm
Tangential Splice Tangential Splice
As = 3142 mm2 As = 3142 mm2
Y: 4@227 Y: 4@214
Z: 3@84 Z: 3@84

Factored Design Loads


Load N T Vz My Vy Mz Mres Theta
Case/Combo (kN) (kNm) (kN) (kNm) (kN) (kNm) (kNm)
1 (W) -1733.3 1.9 -25.0 75.7 14.9 -48.8 90.1 213º
2 (W) -1845.8 1.9 -25.0 -50.9 14.9 25.6 57.0 27º
3 (W) -1157.4 4.3 -61.1 183.8 47.2 -193.1 266.6 226º
4 (W) -1157.4 4.4 -61.1 -122.6 47.2 42.8 129.8 19º
5 (W) -1035.1 1.3 -17.2 52.0 10.1 -35.5 62.9 214º
6 (W) -1035.1 1.3 -17.2 -34.9 10.1 15.1 38.1 23º
7 (W) -1.0 2.0 0.0 1.0 424.7 1153.8 1153.8 90º
8 (W) -1.0 2.1 0.0 -1.7 426.0 3301.1 3301.1 90º

diab Page 1 #100 - 1234 Anywhere Place


USER January 15, 2018 AnyCity, AnyState
Ph: 555-1234 Fax: 555-4321 10:55 PM AnyCountry
S-CONCRETE Version 7.02
© Copyright 2006 by Softek Services Ltd.

9 (W) 30.6 2.3 0.8 -3.1 408.3 1115.5 1115.5 90º


10 (W) 30.6 2.3 0.8 3.1 409.6 3179.9 3179.9 90º
11 (W) 33.9 -0.5 1.4 -8.3 60.8 37.5 38.4 77º
12 (W) 33.9 -0.7 2.8 10.7 60.8 343.6 343.8 92º
13 (W) 70.9 -0.1 2.4 -13.5 38.5 -7.0 15.2 333º
14 (W) 70.9 -0.4 3.7 16.7 38.5 186.5 187.2 95º

N vs M Results Axial Utilization Moment Utilization


GLC 8 Nu = -1.0 kN Mu = 3301.1 kNm Mn = 4332.6 kNm
Status Acceptable ØNn (max) = -17415.5 kN ØMn = 3899.4 kNm Mp = 5344.5 kNm
Utilization 0.847 Utilization = 0.000 Utilization = 0.847
Maximum 1.000
Theta 90º

Shear Utilization Shear Z-Direction Shear Y-Direction


GLC 8 Nu = -1.0 kN Nu = -1.0 kN
Status Acceptable Mu (y-y) = -1.7 kNm Mu (z-z) = 3301.1 kNm
Utilization 0.391 = Uz + Uy Vuz = 0.0 kN Vuz = 426.0 kN
Maximum 1.000 bw = 3000 mm bw = 300 mm
d = 240 mm d = 2400 mm
As (Tens) = 7417 mm2 As (Tens) = 5924 mm2
Torsion Av = 0 mm2 Av = 402 mm2
Tu = 4.4 kNm Lambda = 1.00 Lambda = 1.00
T (limit) = 42.2 kNm ØVsz = 0.0 kN ØVsy = 748.2 kN
Acceptable ØVcz = 539.1 kN ØVcy = 340.4 kN
ØVny = 539.1 kN ØVny = 1088.6 kN
Util (Uz) = 0.000 Util (Uy) = 0.391

Panel 1 Reinforcing

?16 @ 406 V.E.F Vert Steel Ratio Vert Bar Spacing Number of Curtains
Rho = 0.00330 S = 406.4 mm Curtains Specified = 2
Rho (min) = 0.00250 S (min) = 70.1 mm Curtains Required = 2
Rho (max) = 0.01000 S (max) = 457.2 mm Acceptable
Acceptable Acceptable

?16 @ 406 H.E.F Horz Steel Ratio Horz Bar Spacing Clear Cover
Rho = 0.00330 S = 406.4 mm Cover Specified = 40.0 mm
Rho (min) = 0.00250 S (min) = 54.1 mm Max Cover = 100 mm
Acceptable S (max) = 457.2 mm Acceptable
Acceptable

Zone A Reinforcing 10?20 Vert ?10 Ties @ 406 mm

Vertical Bar Spacing Vertical Bar Spacing Tie Spacing Splice Type
C-to-C low (y) = 227 mm C-to-C low (z) = 84 mm S = 406 mm Tangential
C-to-C high (y) = 227 mm C-to-C high (z) = 84 mm S (min) = 58 mm Acceptable

diab Page 2 #100 - 1234 Anywhere Place


USER January 15, 2018 AnyCity, AnyState
Ph: 555-1234 Fax: 555-4321 10:55 PM AnyCountry
S-CONCRETE Version 7.02
© Copyright 2006 by Softek Services Ltd.

Minimum (y) = 78 mm Minimum (z) = 78 mm S (max) = 406 mm


Maximum (y) = 457 mm Maximum (z) = 457 mm Acceptable
Acceptable Acceptable

Area of Zone Steel Tie Diameter Misc Information


As = 3142 mm2 d (tie) = 10 mm Scl (limit) = 152 mm
As (min) = N/A d (min) = 10 mm
As (max) = 9600 mm2 Acceptable
Ag (zone) = 240000 mm2
Acceptable

Zone B Reinforcing 10?20 Vert ?10 Ties @ 406 mm

Vertical Bar Spacing Vertical Bar Spacing Tie Spacing Splice Type
C-to-C low (y) = 214 mm C-to-C low (z) = 84 mm S = 406 mm Tangential
C-to-C high (y) = 214 mm C-to-C high (z) = 84 mm S (min) = 58 mm Acceptable
Minimum (y) = 78 mm Minimum (z) = 78 mm S (max) = 406 mm
Maximum (y) = 457 mm Maximum (z) = 457 mm Acceptable
Acceptable Acceptable

Area of Zone Steel Tie Diameter Misc Information


As = 3142 mm2 d (tie) = 10 mm Scl (limit) = 152 mm
As (min) = N/A d (min) = 10 mm
As (max) = 9144 mm2 Acceptable
Ag (zone) = 228600 mm2
Acceptable

Vertical Reinforcing Horizontal Reinforcing


fy (min) 275.8 MPa fy (min) 275.8 MPa
fy (vert) 420.0 MPa fy (horz) 420.0 MPa
fy (max) 551.6 MPa fy (max) 413.7 MPa
Status Acceptable Status Warning Message 18

Concrete Strength Concrete Density


fc' (min) 17.2 MPa Wc (min) 1441.7 kg/m3
fc' 40.0 MPa Wc 2402.8 kg/m3
fc' (max) 68.9 MPa Wc (max) 2482.9 kg/m3
Status Acceptable Status Acceptable

British Reinforcing Bars

Index Bar Diameter Area


Designation (mm) (mm2)

1 ?6 6.0 28.3
2 ?8 8.0 50.3
3 ?10 10.0 78.5
4 ?12 12.0 113.1
5 ?16 16.0 201.1

diab Page 3 #100 - 1234 Anywhere Place


USER January 15, 2018 AnyCity, AnyState
Ph: 555-1234 Fax: 555-4321 10:55 PM AnyCountry
S-CONCRETE Version 7.02
© Copyright 2006 by Softek Services Ltd.

6 ?20 20.0 314.2


7 ?25 25.0 490.9
8 ?32 32.0 804.2
9 ?40 40.0 1256.6
10 ?50 50.0 1963.5

Wall Dimensions Lu (y-y) = 3048 mm, Lu (z-z) = 3048 mm, hw = 25000 mm

Panel 1 Thickness
T = 300 mm
T (min) = 122 mm
Acceptable

List of Messages

Message 18 Warning fy of Shear/Horizontal Reinforcing is not within an Acceptable range.


Clause 11.5.2 and 11.6.3.4 ACI 318, 40 <= fy <= 60 ksi

diab Page 4 #100 - 1234 Anywhere Place


USER January 15, 2018 AnyCity, AnyState
Ph: 555-1234 Fax: 555-4321 10:55 PM AnyCountry