[ 15.9 ]
Minimum Quantity ... 1,000 100 ......
0.62 [ 47.9 ]
1.88
[ 15.9 ] [ 17.0 ]
0.62 0.67
[ 81.3 ]
3.20
[ 47.9 ]
1.88
[ 83.1 ]
3.20
Minimum Quantity.... 1,000 100 ...
[ 11.1 ] [ 30.0 ]
0.44 1.18
Minimum Quantity ........................ 1,000 100 ........................
A
[ 7.2 ]
[ 7.1 ]
0.28
0.28
[ 11.9 ]
0.47
[ 2.0 ]
0.08
[ 69.1 ]
2.72
[ 22.2 ]
0.87
[ 48.0 ]
1.89 Standard
See PCB contact [ 66.0 ] Powerclaw
drawing on website 2.60 Contact
[ 32.8 ]
for further detail. 1.29
Second housing and contact
in two pole version only.
75 75 75
50 50 50
25 25 25
0 20 40 60 80 100 120 0 10 20 30 40 50 60 70 80 90 100
0 10 20 30 40 50 60 70 80 90 100110
Amperes Applied Amperes Applied Amperes Applied
6 AWG 8 AWG 6 AWG 8 AWG Singlepole 2-Pole
10 AWG 12 AWG 10 AWG 12 AWG
PP75 Singlepole Loose Piece Contact PP75 Multipole Loose Piece Contact Mini Powerclaw
Temperature Rise at Constant Current Temperature Rise at Constant Current Temperature Rise at Constant Current
60 60 60
50 50 50
40 40 40
30 30 30
20 20 20
10 10 10
0 0 0
0 10 20 30 40 50 60 70 80 90 100 110 120 0 10 20 30 40 50 60 70 80 90 0 10 20 30 40 50 60 70 80 90
Amperes Applied Amperes Applied Amperes Applied
6 AWG 8 AWG 6 AWG 8 AWG Singlepole 2-Pole
10 AWG 12 AWG 10 AWG 12 AWG
NOTE: Powerclaw charts are based on #8 AWG equivalent copper foil on board side, mated to #6 AWG conductor on wire side.
Materials
Housing Min. Creepage / Clearance Distance PCB in. mm
Standard Plastic Resin Polycarbonate
Chem. Resistant Resin Polycarbonate / PBT blend
Contact Retention Spring Stainless Steel
Contact
Base Copper Alloy
Wire Plating Silver
PCB Plating Sn or Ag over Ni
Unmated 2.97 mm
Single Pole
PP75 Mated 2.97 mm IIIa
Unmated 2.97 mm
Stacked Powerpole®
Mated 2.97 mm
Attributes PP75
AMP Rating AC/DC 75
Protection
Touch Safety with Wire Contacts
[ 5.1 ]
Ø .20 [ 27.4 ]
1.08
- Both Versions - Both Versions
Spacer
Use to separate housings under high power to minimize power capability derating
due to heat rise. They are recommended for squaring off a block of Powerpole ® 75 [ 17.0 ] [ 17.0 ]
0.67 0.67
housings to enable mounting accessories or retaining pins to be used. Combining
long and short spacers opposite each other in a mated block adds keying features,
or use two short spacers to avoid interference.
[ 33.3] [ 47.6 ]
Minimum Quantity… 1000 100 .... 1.31 1.87
Mounting Clamp
Mounting clamps can be used for fastening a block of Powerpole® 75 series
housings to a panel. Connector blocks must be a complete square for the
clamps to work properly. Fastening hardware not included.
Mounting Clamp
Panel
Retaining Pins
Retaining pins are used to keep stacked Powerpole® 75 series housings from separating.
Retaining pins are inserted in the circular opening between two housings stacked side by side.
mm.
B
PCB Mounting Staples A
of the PCB board to lock the housings in place. Staples are an inter
Staple
Housings
be used with the connector. Electrical capability is derated with smaller wire.
Length ID
Wire Entrance
[ 22.2 ]
Minimum Quantity ... 500 50 ....... 0.88 [ 69.9 ]
2.75
[ 22.2 ] [ 23.7 ]
0.88 0.93
[ 117.5 ]
4.63
-A-
[ 21.3 ] [ 50.8 ]
0.84 2.0
B
[ 10.4 ]
0.41