Professional Documents
Culture Documents
AN TU
M
D
R
ED
N
Defigard 4000
LT Book für
ED A
IN EUR
inhouse-Druck
GN
SI
O
E
P
D E
R
GNED AN
ED
Offset-Druck
SI
O
E
D E
Austria
SCHILLER Handelsgesellschaft m.b.H.
Defibrillator: A-4040 Linz
- Defibrillation waveform: Pulsed biphasic – MULTIPULSE BIOWAVE® Phone +43 732 709 90
- Defibrillation through paddles or pads Fax +43 732 757 000
sales@schiller.at
- Energy setting: 2 to 200 J www.schiller.at
- AED mode with pads; children pads recognition and automatic energy
adaptation China
- Defibrillator mode: Synchronize and Unsynchronize SCHILLER Int‘l Trading (Shanghai) Co. Ltd.
200335 Shanghai, China
Pace maker (option): Phone +86-21-62099627
Fax + 86-21-62099623
- Mode: Fix, demand, OverDRIVE sales@schiller.com.my
- Using the same pads as for defibrillation www.schiller.cn
ECG: France
- Input: CF class patient cable 3 or 4 leads (option) SCHILLER Médical S.A.S.
- Leads: I, II, III, aVR, aVL, aVF (according to the patient cable connected) F-67162 Wissembourg/Cedex
Phone +33 3 88 63 36 00
Fax +33 3 88 94 12 82
SpO2 (option): info@schiller.fr
- Masimo or Nelcor www.schiller-medical.com
- ON/OFF by cable detection France (distribution France)
SCHILLER France S.A.S.
Alarms: F-77600 Bussy St Georges
- System alarms: Monitor, defibrillator, battery charge, recorder and memory Phone +33 1 64 66 50 00
Fax +33 1 64 66 50 10
- Physiological alarms: ECG, SpO2 infoschiller@schiller-france.fr
- Technical alarms: All parameters www.schiller-france.com
Germany
Printer: SCHILLER Medizintechnik GmbH
- 3-channel thermal printer, Z-folded paper, width 72 mm D-85521 Ottobrunn
- Chart print-out speed: 25 mm/s Phone +49 89 62 99 81-0
- Operating mode: Automatic or manual Fax +49 89 609 50 90
info@schillermed.de
www.schillermed.de
Printout:
Curves, measurements, date and time, alarms Hungary
SCHILLER Diamed Ltd.
H-1141 Budapest
Memory: Phone +36 (1) 383-4780 / 460-9491
Internal memory to store 80 minutes ECG, 80 minutes ambient noise (voice) and Fax +36 (1) 383-4778
sales@schiller.at
500 events (duration, number of shocks, date and time of shock) www.schiller-hungary.hu
Communication (option): India
Internal modem to send AED data or one ECG lead and monitored values SCHILLER Healthcare India Pvt. Ltd.
Mumbai - 400 001, India
Phone +91 22 6692 0520/ 2826 3520
Power supply: Fax +91 22 2826 3525
- Mains power supply: 100–240 V, 50/60 Hz sales@schillerindia.com
www.schillerindia.com
- Battery: Lead-acid
- Autonomy: 3h 30. Japan
- Charging time: 4 h (for 80 %) and 6 second to 200 joule SCHILLER Japan, Ltd.
- Battery level control: Charging and discharging indication on screen Hiroshima 734-8551
Phone +81 82 250 2055
Fax +81 82 253 1713
Environment conditions: koji.maekawa@schiller.jp
Dimensions (h x w x d): 270 x 310 x 160 mm www.schiller.jp
Weight: 5.3 kg with all options, battery and paddles Poland
SCHILLER Poland Sp. z o.o.
PL-02-729 Warszawa
Standard equipment/options: Phone +48 22 8432089
Fax +48 22 8432089
schiller@schiller.pl
DEFIGARD 4000 with: Paddles Pads www.schiller.pl
Display • •
Russia & C.I.S.
Alarms • • SCHILLER AG Rep. office
Power: mains + battery (SLA) • • 125124 Moscow, Russia
Manual defibrillation • • Phone +7 (495) 970 11 33
3-lead ECG cable • • Fax +7 (495) 970 11 33
mail@schiller-ag.com
Printer • www.schiller-cis.com
AED mode º
*2.500492* 07/10
SpO2 º Spain
º SCHILLER ESPAÑA, S.A.
4-lead patient cable º º E-28230-Las Rozas/Madrid
Pacemaker º º Phone +34 91 713 01 76
Modem º º Fax +34 91 355 79 33
schiller@schiller.es
www.schiller.es
• Standard
º Option Switzerland
SCHILLER-Reomed AG
CH-8953 Dietikon
Technical data and images are subject to change without notice. Phone +41 44 744 30 00
Fax +41 44 740 37 10
sales@schiller-reomed.ch
www.schiller-reomed.ch
Part no.: 2.500492
Turkey
SCHILLER TÜRKIYE
Okmeydani-Sisli – Istanbul
Phone +90 212 210 8681 (pbx)
Fax +90 212 210 8684
info@schiller.com.tr
www.schiller-turkiye.com
Headquarters: SCHILLER AG, Altgasse 68, CH-6341 Baar, Switzerland, Phone +41 41 766 42 42, Fax +41 41 761 08 80, sales@schiller.ch, www.schiller.ch