STEP 1: DOUBLE CLICK ON FloormapVS Data
Acquisition.

STEP 2: YOU CAN SEE THIS SCREEN


STEP 3: CLICK ON SCAN

STEP 4: PLATE SETUP SCREEN OPENS. CLICK ON PLATE.


STEP 5: ENTER THE FOLLOWING
1) ROW NUMER & PLATE NUMBER
2) PLATE LENGTH & PLATE WIDTH (refer TANK document given)
3) SELECT HORIZONTAL PLATE DIRECTION
4) DIRECTION OF SCAN (always select parallel only)

Click on Horizontal
Plate Scan

Click on
Parallel Scan

STEP 5: CLICK ON CREATE


STEP 7: THIS SCREEN APPEARS

STEP 8: PLACE THE EQUIPMENT ON ONE EDGE AT


ZERO POSITION. CLICK ON SCAN

ZERO POSITION
STEP 9: PRESS ENTER. (DO NOT CHANGE SCAN OFFSET.
IT IS ALWAYS 140 MM)

STEP 10: RUN THE EQUIPMENT. YOU MUST RUN THE


EQUIPMENT BY USING ACCELERATOR (JUST LIKE A
BIKE)

IMPORTANT: DO NOT STOP OR LEAVE ACCELERATOR UNTIL YOU


REACH THE END OF THE PLATE.
STEP 11: STOP THE EQUIPMENT ONCE YOU REACH THE
END OF THE PLATE. THIS SCREEN APPEARS.

STEP 12: CLICK ACCEPT


STEP 13: THIS SCREEN APPEARS. WALL LOSS DUE TO
CORROSION WILL SHOW COLOUR PATTERNS (LIKE PAUT
CORROSION MAPPING)

Wall loss defects

STEP 14: LIFT THE MAGNET AND ROLL THE EQUIPMENT BACK
TO ZERO POSITION ON PLATE FOR SECOND SCAN. CLICK ON
SCAN

Second Scan
Position
STEP 15: PRESS ENTER. (DO NOT CHANGE OFFSET VALUE. IT
IS 140 MM ALWAYS)

STEP 16: THEN THIS SCREEN APPEARS. THEN RUN THE


EQUIPMENT USING ACCELERATOR.
STEP 17: AFTER FINISHING SCAN, PRESS ACCEPT.

STEP 18: THEN THIS SCREEN APPEARS.


STEP 19: SAVE THE PLATE.

YOU FINISHED SCANNING ONE PLATE (ROW 1, PLATE 1)

STEP 20: CLICK ON NEW PLATE


STEP 21: NOW THIS SCREEN APPEARS. IT SHOWS ROW 1
PLATE 2. FOLLOW ALL THE STEPS FROM STEP 4 TO STEP 20.

STEP 22: SCAN ALL THE BOTTOM PLATES

STEP 23: ONCE ALL THE BOTTOM PLATES ARE SCANNED WE


MUST SCAN ANNULAR PLATES. CLICK ON ANNULAR
STEP 24: THIS SCREEN APPEARS.
1) ENTER ANNULAR NUMBER “1”
2) PRESS CUSTOM

STEP 25: THIS SCREEN APPEARS.


1) ENTER ANNULAR NUMBER “1”
2) PRESS CUSTOM
STEP 26: THIS SCREEN APPEARS. ENTER ALL THE FOUR
ANNULAR PLATE MEASURESMENTS. THEN CLICK “GREEN
TICK MARK”

STEP 27: NOW PUT ANNULAR PLATE NUMBER AND CLICK


CREATE.
STEP 28: THIS SCREEN APPEARS. PUT THE EQUIPMENT AT
ZERO POSITION & CLICK SCAN BUTTON

ZERO POSITION

STEP 29 : RUN THE EQUIPMENT. AFTER COMPLETING SCAN,


CLICK ACCEPT.
STEP 30: SAVE THE PLATE

STEP 31: SCAN ALL THE ANNULAR PLATES BY FOLLOWING


ABOVE STEPS.
STEP 32: AFTER SCANNING ALL THE BOTTOM & ANNULAR
PLATES, PRESS EXIT.
STEP 33: THIS SCREEN APPEARS. PRESS ARCHIVE

STEP 34: THIS SCREEN SHOULD APPEAR. CLICK ON “FINISH


INSPECTION.”
STEP 35: THIS SCREEN SHOULD APPEAR. CLICK ON “YES.”

STEP 36: THEN ON THE BELOW SCREEN CLICK “EXIT”