Producto: EXCAVATOR
Modelo: 320C EXCAVATOR CLM
Configuración: 320C U 320C LU Excavators CLM00001-UP (MACHINE)
POWERED BY 3066 Engine
Pruebas y Ajustes
312C, 315C, 318C, 319C, 320C, 321C, 322C, 325C, 330C and M325C Excavators and 325C
MHPU and 330C MHPU Mobile Hydraulic Power Units Engine and Pump Control
Número de medio -RENR3814-17 Fecha de publicación -01/04/2007 Fecha de actualización -18/04/2007
i02149330
Table 1
254
Electronic Control Module (ECM)
( 312C, 315C, and 321C ONLY)
271
Action Alarm
( 312C, 315C, and 321C ONLY)
286
Engine oil pressure fault
(Not in 321C)
374 Swing brake solenoid
376 Travel alarm
581 Proportional reducing valve for the power shift pressure
586 Engine speed dial
587 Feedback of the governor actuator
588 Communication problem between controller and monitor
https://127.0.0.1:7443/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisw... 18/01/2012
320C U 320C LU Excavators CLM00001-UP (MACHINE) POWERED BY 3066 En... Page 2 of 4
Illustration 1 g00691520
Example Of A Typical Troubleshooting Procedure
(1) Preparations
https://127.0.0.1:7443/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisw... 18/01/2012
320C U 320C LU Excavators CLM00001-UP (MACHINE) POWERED BY 3066 En... Page 3 of 4
Illustration 2 g00987164
Diagram Of Terminology For The Troubleshooting Procedures
2. Measurement of Voltage
(A) - (B) : 24 V
Voltage is measured at the later terminal. For example, the red test pin + is connected to terminal "A"
and the black test pin - is connected to terminal "B".
3. Meaning of Symbols
4. Preliminary Check
a. Connector
Check the connection of the connector before a troubleshooting procedure is performed. Inspect
the connector for moisture. Moisture in a connector can cause a poor connection. Ensure that the
connectors are mating correctly. Ensure that the pins in the connector are secure.
b. Continuity
"C-ground" - "P-ground"
"C-ground" - "R-ground"
https://127.0.0.1:7443/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisw... 18/01/2012
320C U 320C LU Excavators CLM00001-UP (MACHINE) POWERED BY 3066 En... Page 4 of 4
"P-ground" - "Cab-ground"
Turn the disconnect switch to the OFF position before you perform the continuity checks. The
power is OFF in order to prevent damage to the tester and the circuit.
5. Preparation
c. Ensure that the controller, the harnesses and the connectors are connected.
Note: Ensure that disconnected wires do not contact the machine in order to avoid damage to
electrical components when power is applied.