GS8000 Optic Switch

User Manual

OPTICOMMS

Add: No.9, 3rd Wuke East Road, Wuhou District, Chengdu PR of China Tel: 86-28-85360759 Fax: 86-28-85367323
E-mail: oversea@ktcatv.com Zip Code: 610045 Http://www.ktcatv.com
Chengdu KT Electronic Hi-tech Co.

Content

1.0 Product Description … … … … … … … … … … … … … …1


2.0 Main Application ………………………………………………….1
3.0 Performance and Index ……………………… …………………1
4.0 Products Series……………………………………………………1
5.0 Main Switch Mode ……………………………… ………..………2
6.0 GS8000 Circuit Principle …………………………..…………2
7.0 Front Display Menu……………… …………………….…………2

Add: No.9, 3rd Wuke East Road, Wuhou District, Chengdu PR of China Tel: 86-28-85360759 Fax: 86-28-85367323
E-mail: oversea@ktcatv.com Zip Code: 610045 Http://www.ktcatv.com
Chengdu KT Electronic Hi-tech Co.

1.0 PRODUCT DESCRIPTION

GS8000 Optic Switch is applied for automatic optic-line switch of optic transmitter

back-up in optic fiber network, when the main optic signal is


defected ,it can switch automatically to the back-up optic-line in order to maintain
the transmission of optic signal. It adopts imported switch mode matching with the
control circuit.

HOSW has very low insert loss ,Typical≤ 0.6dB、 Maximum ≤ 1.0dB) ,with advanced
level internationally, It has three types :1× 2,2× 1or2× 2, 19〃 standard casing ,
Automatic status or manual switch status can be set at front panel. The optic power
through by can be displayed at front panel.

2.0 MAIN APPLICATION

HOSW optic switch is mainly applied in optic circuit switch , optic equipment switch
that demands high reliability operation. Such as CATV system
head-end 1550nm Optic transmitter, EDFA automatic switch of heat-backup,
with the aim of protection of optic route switch, self-healing circle network. Also it can
be adopted in dynamic configure CADM , OXC

,system monitoring and failure protection.

3.0 TECHNICAL INDEX


Wavelength 1260~1360 or 1510~1610nm Insert loss ≤0.6dB Polarization
relative loss ≤0.1dB

Echo loss ≥55dB Channel cross-talk ≥60dB Repeatability ≤±0.02dB


Transmission power ≤500mW Switch time ≤10mS Voltage AC135-250V

Optic connector FC/APC & SC/APC Casing Size 19″×8″×1.75″

4.0 PRODUCT SERIES

GS8201(2×1) Optic Switch

GS8202(2×2) Optic Switch

Add: No.9, 3rd Wuke East Road, Wuhou District, Chengdu PR of China Tel: 86-28-85360759 Fax: 86-28-85367323
E-mail: oversea@ktcatv.com Zip Code: 610045 Http://www.ktcatv.com
Chengdu KT Electronic Hi-tech Co.

5.0 MAIN SWITCH MODE

6.0 GS8000CIRCUIT PRINCIPLE

7.0 IFOSW-201M USER OPERATION INSTRUCTIONS.

STATUS BUTTON SELECTING FOR DISPLAY THE FOLLOWING MENU

1. 1 model FOSW-201M Fiber Optic

2 InputA(dBm) input power 1

FOSW-201M NO INPUT1!

.3. Set the switch point

Under Switch Mode menu, press △ button entering the submenu to amend, press ▽
button to select the mode, press Status button to save and exit the submenu.

Add: No.9, 3rd Wuke East Road, Wuhou District, Chengdu PR of China Tel: 86-28-85360759 Fax: 86-28-85367323
E-mail: oversea@ktcatv.com Zip Code: 610045 Http://www.ktcatv.com
Chengdu KT Electronic Hi-tech Co.

4. IP,SUBNET,GATEWAY, TRAP ADDR1, TRAP ADDR2 address set

Under IP,SUBNET,GATEWAY, TRAP ADDR1, TRAP ADDR2 menu, press △ button


entering the submenu to select the amend position, press ▽ button to select the
amend position, Press Status button to save and exit the submenu.

When Switch Mode is"Automatic State"when the main channel power


is lower than the switching point power, input power of the subordinate channel is
higher than the switching power, select the subordinate channel output, otherwise the
main channel output

When Switch Mode is selected as"Manual: A to 1;B to 2",select main channel output.

When Switch Mode is selected as "Manual: A to 2;B to 1", select


subordinate channel output.

3.set the switch point

Under Switch Mode menu, press △ button entering the submenu to amend, press ▽
button to select the mode, press Status button to save and exit the submenu.

4. IP,SUBNET,GATEWAY, TRAP ADDR1, TRAP ADDR2 address set

Under IP,SUBNET,GATEWAY, TRAP ADDR1, TRAP ADDR2 menu, press △ button


entering the submenu to select the amend position, press ▽ button to select the
amend position, Press Status button to save and exit the submenu.

When Switch Mode is"Automatic State"when the main channel power


is lower than the switching point power, input power of the subordinate channel is
higher than the switching power, select the subordinate channel output, otherwise the
main channel output

When Switch Mode is selected as"Manual: A to 1;B to 2",select main channel output.

When Switch Mode is selected as "Manual: A to 2;B to 1", select


subordinate channel output.