A rectangular HSS 200×300×12 and 6.0 meters long column is pinned at both ends.
Control the given compression members
All given information about the member are as follows:
Geometrical properties:
A=10810mm2 tnom=12mm ix=109mm iy=80mm
Geometrical properties considered in design,(According to TCDCSS-2016)
A=10127mm2 tdes=0.93tnom = 11.16mm ix=109mm iy=80mm
Local buckling limit state,
when the worst case is considered for flange and web,
K y Ly 200000 Fy
75 4.71 127.02 or 2.25
iy 275 Fe
2 E 2 200000
Fey 350.92N/mm 2
75
2 2
K y Ly
iy
Fy
275
Fcry 0.658 Fy 0.658
Fe 350.92
275 198.10N/mm
2
Pn
1201kN Pa 1150kN