You are on page 1of 2

CHE3002 PROCESS INSTRUMENTATION AND CONTROL

Experiment No : Name:
Date : Register No:

Aim:

To control level in a cylindrical tank process by manipulating the exit flow rate.

Description:

The process being simulated is a level control system of a liquid tank. The controller function
is PI (proportional plus integral), in the form of the LabVIEW PID Advanced function.

The mathematical model of the process to be controlled is based on mass balance of the
contents, which is water, in the tank. The mass balance is

A*dh(t)/dt = Fin(t) - Fout(t)

The outflow Fout(t) is assumed to be the same as the pump control signal u(t) (both in unit of
m3/s) and is the manipulated variable.

Based on the data, the transfer function model of the process is


Gp(s) = 0.5 x 10-3 / (1000 s + 1)

Procedure:

Unless otherwise stated, all the default values of the parameters are given in the GUI.
1. Set the desired value of level.
2. Use the above transfer function model, design PI controller manually using direct
synthesis method and evaluate the closed loop performance for different values of the
closed loop time constant (ex. τcL = 10000, 11000, 12000, 13000,14000, 15000).
3. Enter the obtained Kc, τi values (under the tab Your own PI settings).
4. Draw the closed loop graphs for all values of τcL.
5. Now, take any one value of τcL, change τi (ex. τi = 500, 750, 1000, 1250, 1500) and
evaluate the closed loop performance. Draw the closed loop graphs for all values of τi.
6. For a fixed value of Kc, τi, change the set point from 0.5 to 2 and observe the tracking
performance for multiple set-points.
7. Draw the corresponding closed loop graph.