You are on page 1of 8

Std Line ACD6

Screw pump series

Product description

Flow volume: 11-45 l/min


Max differential pressure: 7 bar
Applications: Lubrication, circulation and transfer
ACD6 1116.02 GB
Applications
The ACD pumps are used for a number of and steam turbines, hydro turbines, paper
different fluids: machines.
Lubrication oil, fuel oil, vegetable oil, • Circulation for cooling and filtration in
hydraulic oil and other hydraulic fluids, large machineries and hydraulic systems,
glycols, polymers, emulsions, and any non- pumping transformer oil for insulation in
aggressive fluid with some lubricating transformers.
properties. • Transfer onboard ships, in oil factories,
Typical application are: refineries, tank farms etc.
• Lubrication of diesel engines, gears, gas

Discharge pressure
Technical data
Maximum discharge pressure is 12 bar
Differential pressure
Maximum differential pressure is 7 bar but is reduced at low viscosities as shown in the
table below.
Viscosity, mm2/s (cSt) 2 3 4 5 6 7 8 9 10
Max. diff. pressure (bar) 4.2 4.7 5.1 5.5 5.8 6.0 6.3 6.5 6.7

Inlet pressure Max speed limit


Max. inlet pressure is 7 bar The maximum speed is 3600 rpm. For
Min. inlet pressure is shown in the higher speeds contact IMO AB.
Selection guide
Rotation
Displacement cm3/r The ACD pump is designed to operate in
Size,lead 025L 025N one rotational direction only, as standard
Displacement cm3/r 9.8 13.9 clockwise when facing the shaft end.

Pressure relief valve Fluid viscosity


The pump is equipped with an integral 2-1500 mm2/s. For higher viscosities contact
pressure relief valve with internal return, IMO AB.
limiting the differential pressure across the
pump and protecting the pump should the
discharge line be blocked. The valve is
Pumping temperature
adjustable for different opening pressures. -20°C to 90°C for all types of ACD.
The value of the pressure limit can be set at
the factory and should be adjusted at in- Sound level
stallation (see Installation & Startup A typical sound level from a pump with
instruction for Low pressure pumps). The standard driver is 58 dB(A). This value
valve has a pressure accumulation of max. refers to free field conditions at 5 bar, 2940
4 bar, so with moderate demands on rpm and 40 cSt, measured according to ISO
pressure modulation, it may also be used 3741.
for pressure regulation. The valve has a
max. set pressure of 7 bar. Standard and recommendation
Version NTBP is recommended whenever
Drive the starting viscosity might exceed 800 cSt.
The pump is designed to be short coupled Unless otherwise specified, version IVBP
to an electrical motor IEC size 71. The will be delivered.
motor bearing will have to carry a slight
axial load from the rotor set. With motors
delivered from IMO AB, this load will not
ACD6 1116.02 GB

significantly impair the bearing life expectancy.

2 www.imo.se
Material and design
IVBP NTBP
Pump body Pearlitic cast iron Nodular cast iron
Power rotor Steel, surface treated Steel, surface treated
Idler rotors Pearlitic cast iron, Pearlitic cast iron,
surface treated surface treated
Shaft seal Carbon/Ni-resist Carbide/Carbide
Viton elastomers Viton elastomers
Viscosity table
cSt 2 4 8 20 37 75 200 400 800 1500
SSU 32.6 39.2 52.2 99.4 174 346 927 1850 3700 6940

Units
The following units are frequently used for specification of pumps:
SI-unit IMO units USA units conversion
Pressure Pa (MPa) bar psi 1 bar = 14,5 psi = 0,1 MPa
Speed r/s rpm rpm 1 rpm = 0,016667 r/s
Viscosity mm2/s cSt SSU see table
Temperature °C °C °F °C = (°F-32)/1.8
Length m mm inch 1 mm = 0,0394 inch
Flow rate m3/s lit/min GPM 1 lit/min = 0,264 GPM

Pump model code

Pump series
ACD

Size
(Power rotor diameter, mm)

Lead
L=Low lead
N=Normal lead

Generation
Design generation 6

Material in pump body


I=Perlitic cast iron
N=Nodular cast iron

Shaft seal design


V=Carbon/Ni-resist. elastomers in Viton
T=Carbide/Carbide, elastomers in Viton

Mounting
B=Flange mounting

Valve
P=Pressure relief valve included

Special design
ACD6 1116.02 GB

Code group omitted for standard design

www.imo.se 3
Selection guide 50 Hz
Size Visc. (lit/min) Speed: 1450 rpm Speed: 2900 rpm
& Diff. pressure (bar) Min.inlet Diff. pressure (bar) Min.inlet
Lead (cSt) (kW) 2 4 6 (bar)* 2 4 6 (bar)*

20 Qeff 11.02 9.69 8.68 -0.85 25.23 23.90 22.89 -0.85


Pe 0.10 0.15 0.19 0.24 0.34 0.43

37 Qeff 11.86 10.89 10.14 -0.85 26.07 25.10 24.35 -0.85


025L Pe 0.12 0.17 0.21 0.30 0.39 0.49

75 Qeff 12.56 11.88 11.35 -0.85 26.77 26.09 25.56 -0.85


Pe 0.15 0.20 0.24 0.38 0.48 0.57

400 Qeff 13.50 13.20 12.97 -0.85 27.71 27.41 27.18 -0.82
Pe 0.28 0.33 0.38 0.76 0.85 0.95

20 Qeff 15.19 13.13 11.56 -0.85 35.35 33.29 31.71 -0.85


Pe 0.12 0.19 0.25 0.28 0.41 0.55

37 Qeff 16.50 14.99 13.83 -0.85 36.66 35.15 33.99 -0.85


025N Pe 0.14 0.20 0.27 0.33 0.47 0.60

75 Qeff 17.59 16.53 15.71 -0.85 37.75 36.68 35.87 -0.85


Pe 0.17 0.23 0.30 0.42 0.55 0.69

400 Qeff 19.04 18.59 18.23 -0.85 39.20 38.74 38.39 -0.74
Pe 0.30 0.36 0.43 0.79 0.92 1.05
* Valid for liquids free from unresolved air or gas.

Selection guide 60 Hz
Size Visc. (lit/min) Speed: 1750 rpm Speed: 3500 rpm
& Diff. pressure (bar) Min.inlet Diff. pressure (bar) Min.inlet
Lead (cSt) (kW) 2 4 6 (bar)* 2 4 6 (bar)*

20 Qeff 13.96 12.63 11.62 -0.85 31.11 29.78 28.77 -0.85


Pe 0.13 0.18 0.24 0.31 0.43 0.54

37 Qeff 14.80 13.83 13.08 -0.85 31.95 30.98 30.23 -0.85


025L Pe 0.15 0.21 0.27 0.38 0.50 0.61

75 Qeff 15.50 14.82 14.29 -0.85 32.65 31.97 31.44 -0.85


Pe 0.19 0.25 0.31 0.50 0.61 0.72

400 Qeff 16.44 16.14 15.91 -0.85 33.59 33.29 33.06 -0.78
Pe 0.37 0.43 0.48 0.99 1.11 1.22

20 Qeff 19.36 17.30 15.73 -0.85 43.69 41.63 40.05 -0.85


Pe 0.15 0.23 0.31 0.36 0.52 0.68

37 Qeff 20.67 19.16 18.00 -0.85 45.00 43.49 42.33 -0.84


025N Pe 0.17 0.26 0.34 0.42 0.59 0.75

75 Qeff 21.76 20.70 19.88 -0.85 46.09 45.02 44.21 -0.82


Pe 0.21 0.29 0.38 0.54 0.70 0.86

400 Qeff 23.21 22.76 22.40 -0.85 47.54 47.08 46.73 -0.68
ACD6 1116.02 GB

Pe 0.39 0.47 0.55 1.03 1.19 1.35


* Valid for liquids free from unresolved air or gas.

4 www.imo.se
Pump dimensions
Pump ACD
Dimensions in mm (The counter flanges are accessories)

Fig. 1

Pump unit ACD


Dimensions in mm (With standard electric motor)
ACD6 1116.02 GB

Fig. 2

www.imo.se 5
Accessories
A bare shaft pump (fig. 3) can be ordered with the accessories in fig. 4–7.

Fig. 4 Set of counter flanges


Fig. 5 Angle bracket

Fig. 3 Bare shaft pump

Fig. 6 Double assembly unit


Fig. 7 Electric motor

Installation
The ACD-pump with counter flanges of the connections. The double assembly saves
weld neck type is mounted directly to an space and facilitates installation,
electric motor and has an angle bracket for maintenance, service and supervision. See
mounting horizontally, vertically or any Product Description for T4.
other attitude. Two pump units can also be For more information about installation
mounted to a double assembly on a com- read the Installation and Start-up manual
mon frame with inlet and outlet pipe for low pressure pumps.

Maintenance and Service


Spare parts for these pumps are easily Maintenance and Service instruction for
available from stock. For detailed informa- ACD-pumps or contact IMO AB.
tion and know-how about service read the
ACD6 1116.02 GB

6 www.imo.se
Sectional view
ACD 025, all models
flow out flow in

401

501 556
551
451

451
162
202
134

506 612

612A

601

443 509 1020 614 615 605 602

Fig. 8

List of components
Pos No Denomination Pos No Denomination
1020 Power rotor 551 Rear cover
134 Locking screw 556 Gasket
162 Nylon sleeve socket 601 Valve cover
202 Idler rotor 602 Sealing washer
401 Pump body 605 O-ring
443 Drip nipple 612 Regulating screw
451 Screw 612A Retaining ring
501 Front cover 614 Valve piston
506 O-ring 615 Valve spring
509 Shaft seal
ACD6 1116.02 GB

www.imo.se 7
ZZZLPRVH

ȱDZȱ ǯȱǯȱ˜¡ȱŚŘŖşŖǰȱȱŗŘŜȱŗŚȱ˜Œ”‘˜•–ǰȱ ŽŽ—
ȱ Ž•Ž™‘˜—ŽDZȱƸŚŜȱŞȱśŖȱŜŘŘȱŞŖŖǰȱŽ•ŽŠ¡DZȱƸŚŜȱŞȱŜŚśȱŗśŖş

You might also like