(Alternative Form for Single Chamber, Completely Shop or Field Fabricated Vessels Only)
WO#
As Required by the Provisions of the ASME Boiler and Pressure Vessel Code Rules, Section VIII, Division 1 Page 1 of 2
1. Manufactured and certified by Desarrollos Cavandi, S.A. de C.V., Diagonal Defensores de la Republica 1108 int. 1, Col. Fauna Marina, Puebla,
Pue, 72310, Mexico
(Name and address of Manufacturer)
2. Manufactured for Margger Ingenieros S.A de C.V, Guerrero 68, La Trinidad Sanctorum Cuautlancingo, Puebla, 72730, MEXICO
(Name and address of Purchaser)
3. Location of Installation Pemex Exploración y Producción, Plataforma ELM-3, Sonda de Campeche, Campeche, MEXICO
(Name and address)
Location (Top, Bottom, Minimum Corrosion Crown Radius Knuckle Radius Elliptical Ratio Conical Apex Hemispherical Flat Side to Pressure (Convex or
Ends) Thickness Allowance Angle Radius Diameter Concave)
(a) Right Head 38.1 3.2 N/A N/A 2:1 N/A N/A N/A Concave
(b) Left Head 38.1 3.2 N/A N/A 2:1 N/A N/A N/A Concave
Min Hub
Type ID OD Flange Thk Material How Attached
Bolting
Thk
Location Num & Size Bolting Material
Washer (OD,
Washer Material
ID, thk)
(a) N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A
9. MAWP 7551.12 kPa N/A at max. temp. 168 °C N/A
(Internal) (External) (Internal) (External)
Min. design metal temp. -1 °C at 7551.12 kPa . Hydro, pneu., or comb. test pressure HYDRO at 9806.65 kPa .
11. Supports: Skirt No Lugs None Legs None Other Saddles Attached Welded to reinforcement plate to shell.
(Yes or no) (Number) (Number) (Describe) (Where and how)
12. Remarks: Manufacturer's Partial Data Reports properly identified and signed by Commissioned Inspectors, have been furnished for the following items of the report:
N/A
(Name of part, item number, Manufacturer's name and identifying stamp)
All flanges are ASME B16.5, 600#, except for nozzle N1 SORF 150#. Manhole cover DN 600, SA-105,
Blind flange w/24 pcs Diam. 48mm SA-193 Gr B7 and 48 nuts SA-194 Gr 2H. Exepmt from Impact Testing
per UCS-66.Pressure Relief Device per UG-125 by customer.
FORM U-1A Page 2 of 2
Manufactured by Desarrollos Cavandi, S.A. de C.V., Diagonal Defensores de la Republica 1108 int. 1, Col. Fauna Marina, Puebla, Pue,
72310, Mexico
Manufacturer's Serial No. WOF-18-10-006 CRN N/A National Board No. 2
Vessel constructed by Desarrollos Cavandi, S.A. de C.V. at Puebla, Pue, 72310, Mexico
I, the undersigned, holding a valid commission issued by The National Board of Boiler and Pressure Vessel Inspectors and employed by
Authorized Inspection Associates LLC, of Houston, TX
have inspected the component described in this Manufacturer's Data Report on July 26, 2019 ,
and state that, to the best of my knowledge and belief, the Manufacturer has constructed this pressure vessel in accordance with ASME BOILER
AND PRESSURE VESSEL CODE, Section VIII, Division 1. By signing this certificate neither the Inspector nor his/her employer makes any
warranty, expressed or implied, concerning the pressure vessel described in this Manufacturer's Data Report. Furthermore, neither the Inspector
nor his/her employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with
this inspection.
1. Manufactured and certified by Desarrollos Cavandi, S.A. de C.V., Diagonal Defensores de la Republica 1108 int. 1, Col. Fauna Marina, Puebla,
Pue, 72310, Mexico
(Name and address of Manufacturer)
2. Manufactured for Margger Ingenieros S.A de C.V, Guerrero 68, La Trinidad Sanctorum Cuautlancingo, Puebla, 72730, MEXICO
(Name and address of Purchaser)
3. Location of installation Pemex Exploración y Producción, Plataforma ELM-3, Sonda de Campeche, Campeche, MEXICO
(Name and address)
Certificate of Authorization: Type "U" No. 54158 Expires December 29, 2019