You are on page 1of 3

Beam EC3 Project: Project 1 Page:

1
Version 1.2.1
Beam program based upon EC3 Identification: Beam 1 Date: 26/4/2021
Copyright(C) 2015 StruProg AB Time: 10:33:58
File: Z:\Work Files\All Run Projects\JN1399 - TIMAS - PLEM & ONSHORE PIPE SPOOL\11. FACILITY\1. JACK TEST BEAM\BEAM FOR PAD EYE LOA
1.0 General data
Material : S355 N/NL fy = 355 MPa E= 2.10E+5 MPa
gm0 / gm1 = 1.00 / 1.00
2.0 Profile I 395x395x25x35 Dimensions and weight: Section property: Capacity:
h = 395 mm A = 35775 mm2 Section class: 1
b = 395 mm Ix = 1.298E+7 mm4 My,Rd = 2001.2 kNm
tw = 25.0 mm Iy = 9.702E+8 mm4 Vc,z,Rd = 1998.4 kN
tf = 35.0 mm Iz = 3.599E+8 mm4
g = 280.8 kg/m Iw = 1.165E+13 mm6
Wel,y = 4.912E+6 mm3
Weff,y = 4.912E+6 mm3
Wpl,y = 5.637E+6 mm3

3.0 Beam geometry and loadings (m,kN,kN/m,kNm) Psi0 (Q1) = 0.7 Psi0 (Q2) = 0.7
3.1 Load input
Permanent loads G:
Uniform loads Trapezoidal loads Moment loads Point loads
Span q Span q1 q2 x1 x2 Span M x Span P x
1 1000.00 0.56
1 1000.00 5.33

Variable loads Q1:


Uniform loads Trapezoidal loads Moment loads Point loads
Span q Span q1 q2 x1 x2 Span M x Span P x

Variable loads Q2:


Uniform loads Trapezoidal loads Moment loads Point loads
Span q Span q1 q2 x1 x2 Span M x Span P x

3.2 Plots of beam and loadings


Permanent load : SLS = 1.00 ULS = 1.35
1000.00 1000.00

1
1 5.900 2
Beam EC3 Project: Project 1 Page:
2
Version 1.2.1
Beam program based upon EC3 Identification: Beam 1 Date: 26/4/2021
Copyright(C) 2015 StruProg AB Time: 10:33:58
File: Z:\Work Files\All Run Projects\JN1399 - TIMAS - PLEM & ONSHORE PIPE SPOOL\11. FACILITY\1. JACK TEST BEAM\BEAM FOR PAD EYE LOA

4.0 Support and web stiffeners 5.0 Lateral buckling parameters and load level (underlined C-values are manual input)
Span Support Distance between Span k Restraints C - values top C - values bot.
no. stiffeners web stiffeners (mm) no. Top Bot. Top Bot. C1 C2 C3 C1 C2 C3
1 Weak 1

Location of lateral restraints and web stiffeners

6.0 Results: Design situation (6.10a)


6.1 Diagrams (kN, kNm, mm)
Moment and Shear

1352.3 -768.2

-1347.7
Deformations

-11.9 = L / 495

7.0 Section and Stability control


Member no. 1
Section Control:
Max. posetive moment:
IR = My,Ed / My,Rd = 0.0 / 0.0 = 0.00 < 1.0 ( Ch.6.2.5) at xl = 0.00
Max. negative moment:
IR = My,Ed / MV,y,Rd = 768.2 / 1972.7 = 0.39 < 1.0 ( Ch.6.2.8) at xl = 5.33
IR = Vz,Ed / Vz,Rd = 1352.3 / 1998.4 = 0.68 < 1.0 ( Ch. 6.2.6) at xl = 0.00
Lateral buckling
No lateral buckling
Beam EC3 Project: Project 1 Page:
3
Version 1.2.1
Beam program based upon EC3 Identification: Beam 1 Date: 26/4/2021
Copyright(C) 2015 StruProg AB Time: 10:33:58
File: Z:\Work Files\All Run Projects\JN1399 - TIMAS - PLEM & ONSHORE PIPE SPOOL\11. FACILITY\1. JACK TEST BEAM\BEAM FOR PAD EYE LOA

4.2 Max. forces deformation (kN, kNm, mm)


Forces and Moments Deformations
Span no. xl (m) Shear force Moment
Max. Min. Max. Min. Max. Min.

1 0.00 1352.29 0.00 0.00 0.00 0.0 0.0


0.56 1352.29 -755.93 -4.0
0.56 2.29 -757.28 -4.0
0.59 2.29 -757.35 -4.2
1.18 2.29 -758.70 -7.6
1.77 2.29 -760.05 -10.0
2.36 2.29 -761.40 -11.4
2.95 2.29 -762.75 -11.9
3.54 2.29 -764.10 -11.4
4.13 2.29 -765.45 -10.0
4.72 2.29 -766.80 -7.6
5.31 2.29 -768.15 -4.2
5.33 2.29 -768.19 -4.1
5.33 -1347.71 -768.20 -4.1
5.90 0.00 -1347.71 0.00 0.00 0.0 0.0
Support Reactions
Support no. Force Moment
Max. Min. Max. Min.
1 1352.29 0.00 0.00 0.00
2 1347.71 0.00 0.00 0.00

You might also like