You are on page 1of 1

Event Report

Date/Time Vert at 12:33:24 March 21, 2021 Serial Number UM13557 V 10-89 Micromate ISEE
Trigger Source Geo: 0.500 mm/s, Mic: 2.000 pa.(L) Battery Level 3.8 Volts
Range Geo: 254.0 mm/s Unit Calibration July 16, 2019 by PT. HAS Environm
Record Time 15.0 sec (Auto=3Sec) at 2048 sps File Name UM13557_20210321123324.IDFW
Job Number: 1 Scaled Distance 107.3 (480.0 m, 20.0 kg)
Operator/Setup: Operator/CENDANA.MMB

Notes USBM RI8507 And OSMRE


Location: PIT CENDANA
254
Client: PT BRE
User Name: PT KPP 200
General: SELATAN CENDANA

Microphone Linear Weighting 100


PSPL 19.01 pa.(L) at 2.194 sec
ZC Freq 11.1 Hz
Channel Test Passed (Freq = 20.5 Hz Amp = 1313 mv ) 50

Tran Vert Long


PPV 1.064 0.646 0.851 mm/s

Velocity (mm/s)
ZC Freq 7.2 25 4.2 Hz
Time (Rel. to Trig) 10.375 0.816 3.104 sec 20
Peak Acceleration 0.012 0.018 0.016 g
Peak Displacement 0.106 0.015 0.032 mm
Sensor Check Passed Passed Passed
10
Frequency 7.3 7.3 7.3 Hz
Overswing Ratio 3.6 3.8 3.5
Peak Vector Sum 1.183 mm/s at 3.104 sec
5

1 +
< 1 2 5 10 20 50 100 >
Frequency (Hz)
Tran: + Vert: x Long: ø

MicL 0.0

Long 0.0

Vert 0.0

Tran 0.0

0.0 2.0 4.0 6.0 8.0 10.0 12.0 14.0

Time Scale: 0.50 sec/div Amplitude Scale: Geo: 2.000 mm/s/div Mic: 5.000 pa.(L)/div Sensor Check
Trigger =

Printed: March 22, 2021 (V 10.71 - 10.71) Format © 1995-2014 Xmark Corporation