Diplex B2/B25+B66/B30 (4-2)

Double diplex, 1850-1995 + 1695-1780 / 2110-2360 MHz

Diplex filters achieve significant savings for operators


as they enable several systems and frequency bands to
share antenna or use feeder sharing.

Diplex Filter Design

The Diplex filter B2/B25+B66/B30 is designed according


to Ericsson Radio System concept. It allows combination
and separation of the signals in B2 and B66, or B2 and
B30 frequency bands. The B2 port fully covers the B25
frequency band as well.

Excellent isolation ensures system integrity between the


co-sited systems. The filter is designed for high reliability
and continuous operation in an outdoor environment.

The Diplexer has “DC pass all”, that supports DC + AISG


signaling through the Diplexer to the feeder line, when
TMA and/or RET are used.

Double (4-2)
The “4-2” has 2 ports for B2/B25 and 2 ports for B66/
B30, combined into 2 COM ports.

System Integration

This Ericsson diplex filter has been system verified


together with Ericsson RBSs to ensure high system
performance. Power, AISG-control, and supervision has
also been verified with Ericsson RBSs.
Product Features
• Part of Ericsson Radio System product family
• Excellent isolation performance
• Verified with Ericsson RBSs
• Very low insertion loss
• Indoor and outdoor proof
• Can be used with both Ericsson and non-Ericsson RBSs
• 4.3-10 connectors
• Wall mounting brackets and pole clamps are included

Technical Specifications
PRODUCT NAME DIPLEX FILTER B2/B25+B66/B30 (4-2)
PRODUCT NUMBER KRF 102 409/1
DC CONFIGURATION DC PASS ALL

ELECTRICAL SPECIFICATIONS
Frequency range:
- B2/B25: 1850 - 1995 MHz
- B66: 1695 - 1780 MHz
- B66/B30: 2110 - 2360 MHz

Insertion loss:
- B2/B25: < 0.20 dB*
- B66/B30: < 0.15 dB*

Return loss: > 20 dB


Isolation: > 40 dB
Power handling:
- Continuous power: 50 dBm
- Peak power: 58 dBm

MECHANICAL SPECIFICATIONS
Dimensions (H x W x D): 210 × 116 × 43.5 mm (excl. connectors)
Weight: 2.1 kg
RF connectors: 4.3-10 (f)
Mounting options: Pole or wall mounting

ENVIRONMENTAL SPECIFICATIONS Subject to change without prior notice


Temperature range, full performance: −40 to +55 ºC
MTBF: > 80 years
IP class: IP67
Lightning protection: 5 kA 10/350 μs, 20 kA 8/20 µs (Common mode)
Product safety: International (CB): IEC 62368-1
Europe (CE): EN 62368-1
North America (ETL): CSA/UL 62368-1

* Typical values