You are on page 1of 6

Report of Thorough Examination

Certificate No : 0000 Date of Issuance :- 08-02-2021

Customer Name DO No. PO No


M/S:XXXXXXXXXXXXXX 0000 XXX0000

Minimum Breaking
ID NO. Description Qty
Strength
ELECTRO GALV. TURNBUCKLE
Gear Type: HOOK & EYE 65.76 KN
Nominal Size: 7/8”
0000 00
Finish Galvanized (Shall not be used for
Specification: Commercial grade lifting)
Safety factor(FoS) 3:1
Instructions for use
 Turn buckles are recommended for straight or in-line rigging, tensioning or lashing only.
 Special attention should be paid to prevent overloading.
 While tensioning, the forces on the turnbuckle must not be such that any deformation occurs. In case of deformation, the tension should
be decreased immediately and deformed parts should be replaced. Extreme circumstances or shock loading, if applicable, must be taken
into account when selecting the correct products to be used for the application.
 The WLL should be applied in a straight pull only and overloading is not permitted. Nor should side loads be applied as the products have
not been designed for this purpose.
 It is required that the products are regularly inspected and that the inspection should take place in accordance with the safety standards
given in the country of use. This is required because the products in use may be affected by wear, misuse, overloading etc. with a
consequence of deformation and alteration of the steel structure.
 Never replace an end fitting; other than the one designed for the purpose, as it may not be suitable for the loads imposed.
 Turn buckles should be inspected before use to insure that:
- The threads of the body and the end fittings are of the same type and undamaged;
- The body and end fittings are not distorted or unduly worn; Body and end fittings shall be free from nicks, gouges and cracks.
 The items detailed have been designed and produced to be suitable for normal duties when correctly used by a competent person.
 Examination periods should be determined by a competent person, taking into account the application, environment, frequency of use
and similar matters. But in any event, lifting gear should be thoroughly examined by a competent person at intervals not exceeding six
months to establish their fitness for continued use.

Can fail if damaged, misused or overloaded. Inspect before use. Use by untrained personnel is hazardous.
Observe and do not exceed WLL. DEATH and INJURY can occur from improper use or maintenance.
We hereby certify that the above described material is visually and manually examined and no
defect was noticed during inspection.

Q.C. Inspector: …………….. QA/QC Engr.: ……………..


This certificate is granted subject to the condition that it is understood and agreed that under no circumstances whatsoever shall Al Manar Eastern Factory be
liable for any injury or damage to any person or property occurring by reason of mishandling, over loading, negligent operation or any defect in materials,
machinery , equipment or other items other than such defects ascertainable by normally accepted testing standards and only upon those items actually
inspected by Al Manar Eastern Factory and which are covered by this certificate.

FM. QC. 13 Rev. 01 dated 25-05-2015


Certificate of Conformity

Report No : 0000 Date of Issuance :- 08-02-2021

Customer Name PO .No DO No. Invoice No


M/S: xxxxxxxxxxxxx 000000 00000 --

ID No. Description Quantity


Hot Dipped Galvanized Steel Wire Rope Clips
Gear Type: HD Wire Rope Clips
-- Nominal Size: 3/8” 00
Standard : EN 13411-5
Manufacturer reference: TOYO
Nominal Amount of rope to
Nominal size of Grip Minimum no. of Grips Torque-Nm
diameter(mm) turn back (mm)
3/8” 9 - 10 3 165 61.0

This declaration is valid for 6 months from the date of issue. The declaration’s validity ceases in the event of any
repair or alteration on the equipment in which case it must be re-tested. The above product requires a thorough
examination by a competent person 6 months from the date of issuance or being put into service for the first time after
the period has elapsed.
Fitting instructions: 1) Turn back specified amount of rope from thimble or loop.
Apply first grip one bridge width from dead end of rope.
Apply U-bolt over dead end of wire rope – live end rests in
saddle. Tighten nuts evenly, alternate from one nut to the
other until reaching the recommended torque.
2) When two grips are required, apply the second grip as near
the loop or thimble as possible. Tighten nuts evenly,
alternating until reaching the recommended torque.
3) When three or more grips are required, space additional
grips equally between first two-take up rope slack-tighten
nuts on each U-bolt evenly, alternating from one nut to the
other until reaching recommended torque.

We hereby certify that the above described material is visually and manually examined and no defect was
noticed during inspection.

Q.C. inspector: ___________ QA/QC Engineer: ____________

This certificate is granted subject to the condition that it is understood and agreed that under no circumstances whatsoever shall Al Manar
Eastern Factory be liable for any injury or damage to any person or property occurring by reason of mishandling, over loading, negligent
operation or any defect in materials, machinery , equipment or other items other than such defects ascertainable by normally accepted
testing standards and only upon those items actually inspected by Al Manar Eastern Factory and which are covered by this certificate.

FM. QC. 13 Rev. 00 dated : 09- 06-2014