You are on page 1of 6

11/15/2020 How to wire 3-phase

How to wire 3-phase outlets and surge protection


3 phase outlets and plugs have locking blades
3-phase terminals are marked X-Y-Z-G or X-Y-Z-
W-G
Hot Hot Hot Neutral Ground
If device is marked X Y N G, then it is considered single phase
even though it has 4 wiring terminals

Buy:
3-phase locking outlet
3-phase locking plug

277 480 Three Phase WYE


480 volts across line-to-line
277 volts line-to-neutral

All Wye connections provide


two voltages due to the common
point or neutral connection.

Line-to-line voltage = 480V


Line-to-neutral voltage = 277V
277 Volt x √3 = 479.778 Volt

√3 = 1.7320

Larger image

277 480 Three Phase WYE


4-wire
480 volts across line-to-line
277 volts line-to-neutral
Shows equipment ground

3-phase 4-wire 277-480 volt surge


protection
Buy:
AG4803C3 Type 1 Type 2

Resources:
AG series sell sheet/ pdf Use AG4803CE surge
protector

Larger image

Three Phase 480V


3-wire
480 volts across line-to-line
No system ground
Shows equipment ground

Use AG4803D3 surge


protector

Larger image

waterheatertimer.org/How-to-wire-3-phase-electric.html 1/6
11/15/2020 How to wire 3-phase
Three Phase 480V delta corner ground
4-wire
480 volts across line-to-line

120 208V 3-phase wye


4-wire
208 volts across line-to-line
120 volts line-to-neutral

3 phase 4 wire 208-120 volt surge


Buy:
AG2083C3 Type 1 Type 2/

Resource:
3 phase 120V-208V / 208-208 volt surge protection manual

Larger image

120 208V 3-phase wye


3 phase 4 wire
208 volts across line-to-line
120 volts line-to-neutral
Shows equipment ground

Use AG2083C3 surge


protector

Larger image

120 208V 3-phase wye surge protection


Intermatic AG208C3 Surge protection
Buy:
AG2083C3 Type 1 Type 2/

Resource:
3 phase 120V-208V / 208-208 volt surge protection manual

208 Volt 3-wire delta


3 Phase 3 wire 208 No Neutral

Phase to phase 208V

waterheatertimer.org/How-to-wire-3-phase-electric.html 2/6
11/15/2020 How to wire 3-phase

347 600V three phase wye

600 volts across line-to-line


347 volts line-to-neutral

Larger image

347 600V three phase wye

600 volts across line-to-line


347 volts line-to-neutral
Shows equipment ground

3 phase 4 wire 600 volt surge


protection
Buy:
AG6503C3/ Type 1Type 2

Resources:
3 phase 277V 480V surge protection
manual

Use AG65033 surge


protector
Larger image

347 600V three phase wye


Intermatic AG65033 Surge Protection

Buy:
Intermatic surge protection

Resource:
How to wire 3-phase surge protection

Three Phase 600V

600 volts across line-to-line

No system ground

Shows equipment ground

waterheatertimer.org/How-to-wire-3-phase-electric.html 3/6
11/15/2020 How to wire 3-phase

Larger image

Three phase 250V

250V across each line

No ground

Larger image Use AG2403D3 surge


protector

Three phase 250V

250V across each line

With ground

120-240 High leg Delta


Intermatic AG2403C3 surge
protection

Black Line to Black Line 240V


Black Line to Neutral 120V
Red or Orange Line to Neutral 208V

3-phase 4-wire 4-wire High leg delta


surge
Buy:
AG2403C3 Type 1 Type 2

Resources:
3 phase high leg delta surge protection
manual Use AG2403C3 surge
protector
240-480 High leg Delta
Phase to phase 480V
Phase A Phase C to Neutral 240V
Phase B high leg to Neutral 415V
Voltages are doubled compared with 120-240 high leg

waterheatertimer.org/How-to-wire-3-phase-electric.html 4/6
11/15/2020 How to wire 3-phase

277 480 Volts Single phase

With equipment ground

Use AG48013 Surge


Larger image protector

125 250 Volts Single phase

With equipment ground

277 480 Volts Single phase surge protection

Single phase 277-480V surge


Buy:
AG48013 Type 1 Type

Resources:
Single phase 277-480 / 480-480 volt surge manual/ pdf

waterheatertimer.org/How-to-wire-3-phase-electric.html 5/6
11/15/2020 How to wire 3-phase

3-phase Wire and Breaker size chart

Larger image

waterheatertimer.org/How-to-wire-3-phase-electric.html 6/6