AC Power Solutions

ZoneMaster® Series independently proven to outperform the competition.

The ZoneMaster® Series of surge protectors is engineered to protect wireless equipment from the most severe
transient environment. Specifically tailored to the needs of the cellular/PCS industry, the patented technology
of the ZoneMaster® provides decades of uninterrupted surge protection.

All units also available with filter. Call factory for details.

Specifications ZoneMaster 300 ZoneMaster 150 ZoneSentinel


Joules Per Phase 10,076 5,038 3,023
Maximum Surge Capacity Per Phase 300kA 150kA 90kA
Duty Cycle Performance:
200,000A (8/20µs) >4 Impulses NA NA
100,000A (8/20µs) NA >4 Impulses NA
45,000A (8/20µs) NA NA >4 Impulses
10,000A (8/20µs) >3,500 Impulses >2,500 Impulses >1,500 Impulses
Maximum Continuous Operating Voltage 25% Above Nominal 25% Above Nominal 25% Above Nominal

Operating Temperature Range -40° to +85° C -40° to +85° C -40° to +85° C

Protection Technology (MOV Models) Unique Large Unique Large Unique Large
Block MOV Block MOV Block MOV
Dual Thermal and Dual Thermal and Dual Thermal and
Integrated, Patented, Protection Technology
Current Overload Current Overload Current Overload
(Complies with UL 1449 2nd Edition
Fusing Fusing Fusing
UL94-5V, NEMA UL94-5V, NEMA UL94-5V, NEMA
Enclosure Indoor/Outdoor Indoor/Outdoor Indoor/Outdoor
Module Diagnostics: Protection Present Green LED Green LED Green LED
Fault Warning Visual Flag Visual Flag Visual Flag
Remote Alarm 2Amp Rated NO/NC 2Amp Rated NO/NC 2Amp Rated NO/NC

2
MOV Part # Service Voltage UL1449
kA per Joules per
Phase
N-G
Module
Size*
Redundancy
Phase Levels
models ZoneMaster 300 Series
17100 120/240V Split Ø 3 Wire 330 Volts 300 10,076 Yes A 4
17101 120/208V 3Ø 4 Wire Wye 330 Volts 300 10,076 Yes A 4
17102 120/240V 3Ø 4 Wire Delta 330 Volts 300 10,076 Yes A 4
17103 240V 3Ø 3 Wire Delta 700 Volts 300 10,076 Yes A 4
17104 277/480V 3Ø 4 Wire Wye 700 Volts 300 10,076 Yes A 4
17106 480V 3Ø 3 Wire Delta 1500 Volts 300 10,076 Yes A 4
17107 220/380V 3Ø 4 Wire Wye 700 Volts 300 10,076 Yes A 4
17108 240/415V 3Ø 4 Wire Wye 700 Volts 300 10,076 Yes A 4
ZoneMaster 150 Series
11200 120/240V Split Ø 3 Wire 400 Volts 150 5038 Yes B 2
11201 120/208V 3Ø 4 Wire Wye 400 Volts 150 5038 Yes B 2
11202 120/240V 3Ø 4 Wire Delta 400 Volts 150 5038 Yes B 2
11203 240V 3Ø 3 Wire Delta 800 Volts 150 5038 Yes B 2
11204 277/480V 3Ø 4 Wire Wye 800 Volts 150 5038 Yes B 2
*90515 220/240V Single Ø 800 Volts 150 5038 Yes B 2
11206 480V 3Ø 3 Wire Delta 1500 Volts 150 5038 Yes B 2
11207 220/380V 3Ø 4 Wire Wye 800 Volts 150 5038 Yes B 2
11208 240/415V 3Ø 4 Wire Wye 800 Volts 150 5038 No B 2
11214 120/240V Split Ø 3 Wire 400 Volts 150 5038 No C 2
ZoneSentinel 90 Series
12100 120/240V Split Ø 3 Wire 330 Volts 90 3023 Yes C 0
12101 120/208V 3Ø 4 Wire Wye 330 Volts 90 3023 Yes C 0
12102 120/240V 3Ø 4 Wire Delta 330 Volts 90 3023 Yes C 0
12103 240V 3Ø 3 Wire Delta 700 Volts 90 3023 Yes C 0
12104 277/480V 3Ø 4 Wire Wye 700 Volts 90 3023 Yes C 0
12106 480V 3Ø 3 Wire Delta 1500 Volts 90 3023 Yes C 0
12107 220/380V 3Ø 4 Wire Wye 700 Volts 90 3023 Yes C 0
12108 240/415V 3Ø 4 Wire Wye 700 Volts 90 3023 Yes C 0
12110 240V Single Ø 700 Volts 90 3023 Yes C 0
A= 12“ x 12“ x 6“ approx. 12lbs.; B= 10“ x 8“ x 4“ approx. 7lbs.; C= 8“ x 6“ x 4“ approx. 4 lbs.

A B
C

ZoneMaster 300 Series ZoneMaster 150 Series ZoneSentinel Series

MOV/SAD models provide additional protection for vulnerable or strategic sites


MOV SAD
N-G Redundancy
Part # Description Service Voltage UL1449 kA/Joules kA/Joules Size* Levels
per Phase per Phase Module
11213 ZMS 150 SM 120/240V 3 Wire Split Ø 330 150/5038 12/250 No B 4
17110 ZMS 300 SMM 120/240V 3 Wire Split Ø 330 300/10,076 12/250 No A 4
17111 ZMS 150 SSM 120/240V 3 Wire Split Ø 330 150/5038 24/500 No A 6
17112 ZMS 300 SMMN 120/240V 3 Wire Split Ø 330 300/10,076 12/250 Yes A 6
17113 ZMS 150 SM 120/208V 4 Wire 3 Ø WYE 330 150/5038 12/250 No A 4
17114 ZMS 150 SMN 120/240V 3 Wire Split Ø 330 150/5038 12/250 Yes A 4
17115 ZMS 150 SMN 120/208V 4 Wire 3 Ø WYE 330 150/5038 12/250 Yes A 4
*17116 ZMS 150 SMN 220/380V 4 Wire 3 Ø WYE 800 150/5038 6/250 Yes A 4
*17117 ZMS 150 SM 220/380V 4 Wire 3 Ø WYE 800 150/5038 6/250 No A 4
*=Non UL Listed 3
ZoneMaster® Kits for integration into OEM equipment and cabinets.
Mix and Match from our selection of UL modules and back planes to customize
your application. We can design a solution for all your unique problems.

Protection Modules
Part # Description Technology Joules kA Voltage ◆ Modules include all the standard internal
ZoneMaster features and are supplied
81126/P ZMS MOV 5038 150 120
with a plug-in connector for alarm
81127/P ZMS MOV 5038 150 240
81132/P ZMS N-G MOV 3023 150 120/240 wiring.
81150/P ZSS L1/L2 MOV 3023 90 120
81151/P ZSS L1/L2 MOV 3023 90 240 ◆ Modules and configurations available for
81153/P ZSS L3/G MOV 3023 90 120 all supply voltages including
81154/P ZSS L3/G MOV 3023 90 240
81130/P ZMS SAD SAD >250 12 120 International.

Contact the factory for a complete listing of available modules. ◆ SAD or MOV technology

P/N 90642 P/N 90641 P/N 90640

ZoneBarrier TLP Series -- Tower Light Protection


Engineered to protect tower light controllers
from the most severe transient environment.
Available in a strobe or non-strobe light applica-
tion and can be factory configured to suit unique
combinations of strobes and obstruction lights.

Features
◆ MOV technology
◆ Up to 25,000A surge capacity
◆ Replaceable modules
◆ Low impedance construction
◆ Thermal and short circuit fusing
◆ NEMA 4X enclosure
◆ Five Year Warranty

4
Power Products with integrated surge protection.
Products designed to meet your specific needs.
◆ Uniquely combines high quality surge protection inside cost effective enclosures, pre-assembled and ready
for site installation. Choose from a wide variety of LoadCenters, power and telco cabinets and custom
designs. All models feature our patented ZoneMaster modules providing high capacity surge protection
with dual redundancy, as well as on-board status and remote alarm capabilities.

LoadCenters
Service Per Phase GFI Main Local & Load
Part # UL1449 Size Capacity
Voltage kA Joules Outlet Disconnect Remote Alarm Breakers
11216 120/240V 400 Volts 150 5038 21” x 14” x 5” Yes Yes 200A Yes 100A/1 spare
11224 120/240V 400 Volts 150 5038 21” x 14” x 5” Yes Yes 140A Yes 2-40A/3 spare
11225 120/240V 500 Volts 150 5038 15” x 11” x 5” Yes No 140A Yes 3-80A/2 spare
11226 120/240V 400 Volts 150 5038 34” x 15” x 5” Yes Yes 200A Yes 6-80A/3 spare

Load Center Features:


◆ 10 Year Warranty
◆ Multiple knockout holes
◆ Steel housing, lockable door
◆ Hinged door reveals breakers
and protection status
◆ 150kA surge protection per phase
◆ Large block MOV
◆ Visual and remote alarms
◆ UL 1449 Second Edition Listed
125A Model ◆ NEMA 3R
Our LoadCenters can be provided with transfer switches, generator plugs, additional breaker positions, SAD
surge protection modules, etc. Call the factory for details.

Integrated Utility Enclosures


Atlantic Scientific provides modular, NEMA 3R rated and UL Listed cabinet design solutions for your
AC power/Telco requirements.

◆ Cabinet Configurations ◆ Options


• Split top and bottom • Alarms
• Back-to-back • Fans
• Side-by-side • Filters
◆ Construction • Heaters
• Powdercoat painting • Power Fail Alarm
• Aluminum ◆ Surge protection for AC and Communications
• Stainless steel hardware

5
ZoneMaster PLUS for “Strategic” sites.

Completely Modular Design


◆ 150 - 600kA of surge protection ◆ Extended Power Filter option
◆ MOV and/or SAD technology ◆ Multi-mode Surge Counter option
◆ All-mode configured L-G & L-N ◆ Fused disconnect standard
◆ Redundancy in every module ◆ Uses all standard ZoneMaster modules

Duty Cycle Performance (surge life)


Repetitive Surge Maximum Number
Maximum Surge
Current of Current Long Duration
Current
(>4 Impulses Impulses at Surge Current
Per Mode
Per Mode) 10,000 (8/20) µs)
(10/1,000µ
ZoneMaster PLUS 150 150,000A 100,000A 2,500
2,900A
ZoneMaster PLUS 250 125,000A 100,000A 2,500
2,900A
ZoneMaster PLUS 300 150,000A 100,000A 2,500
2,900A
ZoneMaster PLUS 450 300,000A 200,000A 3,500
5,800A
ZoneMaster PLUS 600 300,000A 200,000A 3,500
5,800A

Optional Silicon Avalanche Diode Technology


For mission critical sites, the ZoneMaster PLUS can be configured with Silicon Avalanche Diodes (SAD) modules.
The SAD modules, combined with the MOV modules, provide an extremely low let-through voltage.

Specifying and Ordering ZoneMaster PLUS and ZoneMaster PLUS SAD/MOV


Series Code Service Voltage Code Option Code
ZoneMaster PLUS 150 = 181 120/240V 00 *Extended Range Filter X
ZoneMaster PLUS 150 SAD = 192* 120/208V 3 Ø 4 Wire WYE 01 Surge Counter - 120V C1
ZoneMaster PLUS 150 SAD = 196** 120/240V 3 Ø 4 Wire Delta 02 Surge Counter - 277V C2
ZoneMaster PLUS 250 = 182 277/480V 3 Ø 4 Wire WYE 04 Audio/Visual Panel Alarm A
ZoneMaster PLUS 300 = 183 220/380V 3 Ø 4 Wire WYE 07
ZoneMaster PLUS 300 SAD = 194* 240/415V 3 Ø 4 Wire WYE 08
ZoneMaster PLUS 450 = 184
ZoneMaster PLUS 600 = 185
* = one SAD module per phase
** = two SAD modules per phase

Examples:
18100 (Series Code 181 and Service Voltage Code 00) = ZoneMaster PLUS 150 for 120/240V Operation
18402XC1 (Series Code 184, Service Voltage 02 and Option XC1) = ZoneMaster PLUS 450 for 120/240V, with Filter
and Counter
18204XC2A (Series Code 182, Service Voltage 04 and Option XC2A) = ZoneMaster PLUS 250 for 277/480V 3 Ø WYE
with Extended Filter, Surge Counter and Alarm
*Extended Range Filter Option X must be purchased at time of initial purchase only.
Note: Upgrade packages available for ZoneMaster PLUS 150, 300 and 450. Call factory for details 800-544-4737.
ZoneMaster PLUS 600 cannot be ordered with the extended range filter option.
6
Data, Communications and Alarm Solutions
ZoneBarrier® Series protection for T-1, POTS and DATA lines
◆ Fast, easy installation
◆ Precise control of transients
◆ High surge current capacity
◆ Completely modular
◆ Holes for individual mounting
◆ Mechanism for DIN Rail Mounting
◆ Expandable protection for one to an
unlimited number of ports
◆ Patch cables provided for all “connector” products

Connector Max Clamp Max


Part # Description Operating Surge
Type Voltage Current
Frequency
*24501 Secondary 2 Wire Dial-Up RJ11 N/A 270 Volts 1,900A
*24503 Secondary 4 Wire Lease Line RJ11 N/A 105 Volts 1,900A
*24507 Secondary 4 Wire T-1 (rooftop) RJ48C >50MHz 225 Volts 1,900A
24534 Primary E-1 BNC >150MHz 30 Volts 10,000A
24549 2 Wire ISDN RJ45 >80MHz 105 Volts 1,900A
**24553 Primary Capacity T-1 (rooftop) Terminal Strip >50MHz 225 Volts 10,000A
24559 8 Wire ISDN RJ45 >50MHz 105 Volts 1,900A
70023 T-1 at Rack DB9 >50MHz 27 Volts 1,000A
90700 T-1 Between Smartjack & Equipment RJ48C >50MHz 27 Volts 10,000A
90663 T-1 Between Smartjack & Equipment Terminal Strip >50MHz 27 Volts 10,000A
90698 Tower Light Alarms 12V Unipolar Terminal Strip N/A +27/ -1 Volts 10,000A
*UL 497A Listed
**UL 497 and UL 497A Listed

DCpowerCAT Series

The DCpowerCAT surge protector protects both DC power and 100BaseT data in the CAT5 cable running
between the indoor and outdoor units. Designed for specific WLL and MMDS broadband equipment, the
DCpowerCAT is available in DIN rail mounted modules or can be combined with AC power protection.

Typical Max Operating Clamping Max Surge


Part # Connector
Application Frequency Voltage Current
24560 BreezeCOM RJ45 250 MHz 10V data, 23V DC 1000A/wire
24561 Adaptive Broadband RJ45 250MHz 10V data, 72V DC 1000A/wire

7
10 Year No Fuss Warranty
If it fails, we replace it immediately!

In the event that any component or subassembly within the unit fails during the ten
year warranty period, just call our customer service hot line, 800-544-4737
to obtain a Return Authorization Number and Atlantic Scientific Corporation will
immediately ship a replacement for the defective unit free of charge (installation labor
and site preparations excluded).

Then return the defective unit to Atlantic Scientific within 30 days of receiving the
replacement. It’s just that simple.

No Hidden Limits - No Nonsense

Explore our web site at: www.atlanticscientific.com

Atlantic Scientific Corporation


Produces over 2000 Surge Protection
Devices. Consult your sales engineer
for additional product
information and
availability.

In the Americas call: In Europe call:

Pondswick Road,
4300 Fortune Place, Suite A Luton, Beds, UK LU1 3LH
W. Melbourne, FL 32904 +44(0)1582 429464 · FAX +44(0)1582 459669
800-544-4737 · FAX 321-727-0736 enquiry@telematic.com
sales@atlanticscientific.com

A member of the MTL Instruments Group plc

Rev A 06/15/01

You might also like