Op nbr 777-010
Suitable container
Removing
2. NOTICE
Always handle oils and other environmentally hazardous fluids in an environmentally safe manner.
Place a suitable container underneath the vibration motor to catch any oil that may leak from the motor upon
removal.
3. Remove the two hexagon screws at the vibration motor on the left side of the drum. Remove the vibration motor
away from the machine.
Figure 1
Eccentric coupling and shaft
1. Shaft
2. Coupling
3. Vibration motor
Installing
5. Lubricate the new shaft and coupling. Insert the shaft into the eccentric weight.
6. Lightly coat the coupling with an approved lubricant. Install the coupling onto the splined shaft of the vibration
motor.
7. Before re-installing the vibration motor, inspect the O-ring on the mounting flange and replace, if necessary.
9. Re-install the hexagon screws at the vibration motor. Use a thread locking compound and torque the hexagon
screws to specification. Refer to Tightening torques