You are on page 1of 31

Test Report PRIMERGY TX1310 M1 with CentOS 2015-01-30

Test Report
PRIMERGY TX1310 M1 with CentOS

Content
Release Overview 2
Warranty conditions 3
Disclaimer of liability 3
Support 3
References 3
Test configuration conf 4
PRIMERGY TX1310 M1 with CentOS 7.0 (x86_64) 5
PRIMERGY TX1310 M1 with CentOS 6.6 (x86) 7
PRIMERGY TX1310 M1 with CentOS 6.6 (x86_64) 9
PRIMERGY TX1310 M1 with CentOS 6.5 (x86) 11
PRIMERGY TX1310 M1 with CentOS 6.5 (x86_64) 13
PRIMERGY TX1310 M1 with CentOS 6.4 (x86) 15
PRIMERGY TX1310 M1 with CentOS 6.4 (x86_64) 17
PRIMERGY TX1310 M1 with CentOS 5.11 (x86) 19
PRIMERGY TX1310 M1 with CentOS 5.11 (x86_64) 21
PRIMERGY TX1310 M1 with CentOS 5.10 (x86) 23
PRIMERGY TX1310 M1 with CentOS 5.10 (x86_64) 25
PRIMERGY TX1310 M1 with CentOS 5.9 (x86) 27
PRIMERGY TX1310 M1 with CentOS 5.9 (x86_64) 29

Page 1 of 31 www.fujitsu.com/primergy
Test Report PRIMERGY TX1310 M1 with CentOS 2015-01-30

Release Overview
This paper comprises the test reports of the PRIMERGY TX1310 M1 with the free operating system CentOS versions and platforms as described as
follows.

OS Conf. OnBoard SATA Controller

CentOS 7.0(x86_64) YES(Note 5)

CentOS 6.6(x86) YES(Note 5)

CentOS 6.6(x86_64) YES(Note 5)

CentOS 6.5(x86) YES(Note 5)

CentOS 6.5(x86_64) YES(Note 5)

CentOS 6.4(x86) YES(Note 5)

CentOS 6.4(x86_64) YES(Note 5)

CentOS 5.11(x86) YES(Note 5)

CentOS 5.11(x86_64) YES(Note 5)

CentOS 5.10(x86) YES(Note 5)

CentOS 5.10(x86_64) YES(Note 5)

CentOS 5.9(x86) YES(Note 5)

CentOS 5.9(x86_64) YES(Note 5)

Legend
Yes: Installable No: Not installable -: Unknown
Note: Check that ServerView Agents are only installed on target operating system.
Explanatory notes
1. Requires LAN driver
2. Install in TEXT mode
3. Requires SAS controller driver and LAN driver
4. Requires SAS controller driver
5. Requires SATA controller driver
6. Can be installed logically
7. Other

Page 2 of 31 www.fujitsu.com/primergy
Test Report PRIMERGY TX1310 M1 with CentOS 2015-01-30

Warranty conditions
Fujitsu is providing all work for customer’s convenience only under the conditions of Fujitsu’s general Warranty Disclaimer for Community and
Regional Linux: ftp://ftp.ts.fujitsu.com/community-linux/Community_Linux_Warranty_Disclaimer.pdf

The information presented in the CentOS test reports is strictly based on results obtained in a test environment prepared by Fujitsu and is not
intended to guarantee operation of a free operating system in the customer’s user environment or to encourage use of a free operating system.
Information contained in this document may be subject to change without notice.

Disclaimer of liability
Due to many hardware and software components involved, the possibility of system crashes, data loss or other negative consequences for your
system cannot be excluded. Fujitsu shall not bear responsibility for any loss that the customer may incur as a result of having installed and/or
used a free operating system based on the verification data presented here.
Fujitsu Customer Service is unable to accept inquiries or provide support relating to the use of PRIMERGY on free operating systems.
Customers are therefore requested to take full responsibility for the installation and use of such free operating systems.
Hardware repair and maintenance shall be limited to machines operating under the duly supported OS environment.

Support
Support is only provided by the CentOS community. Please refer to the Warranty Disclaimer for details on Warranty and Liability of the
downloaded ServerView agents and ServerView RAID Manager.

References
Fujitsu Linux Internet: http://ts.fujitsu.com/linux
Community and Regional Linux FTP site: ftp://ftp.ts.fujitsu.com/community-linux
Warranty Disclaimer: ftp://ftp.ts.fujitsu.com/community-linux/Community_Linux_Warranty_Disclaimer.pdf
Fujitsu “Drivers & Downloads” site: http://support.ts.fujitsu.com/download/index.asp
OS compatibility matrix: http://docs.ts.fujitsu.com/dl.aspx?id=d4ebd846-aa0c-478b-8f58-4cfbf3230473

Page 3 of 31 www.fujitsu.com/primergy
Test Report PRIMERGY TX1310 M1 with CentOS 2015-01-30

Test configuration conf

Hardware environment:
PRIMERGY TX1310 M1
■ CPU : Intel® Xeon® CPU E3-1266 V3 @ 3.30GHz / 8MB / 4core x1
: Intel® Xeon® CPU E3-1246 V3 @ 3.5GHz / 8MB / 4core x1 (CentOS 5.11, 6.6, 7.0)
■ Memory : 4GB, 8GB(CentOS 5.11, 6.6, 7.0)
■ NIC : Onboard 10BASE-T/100BASE-TX/1000BASE-T x2
■ HDD : SATA HDD 2TB ×1, BC-SATA HDD 1TB x2 (CentOS 5.11, 6.6), BC-SATA HDD 500GB x1 (CentOS 7.0)
■ External storage : Internal DVD drive

Device driver [Driver name]:


■ LAN : Intel Corporation Ethernet Connection I217-LM (rev 04) [e1000e]
Intel Corporation I210 Gigabit Network Connection (rev 03) [igb]
■ VGA : Intel Corporation Xeon E3-1200 v3 Processor Integrated Graphics Controller (rev 06)
■ RAID : Intel Corporation C600/X79 series chipset SATA RAID Controller (rev 04) [megasr]

Page 4 of 31 www.fujitsu.com/primergy
Test Report PRIMERGY TX1310 M1 with CentOS 2015-01-30

PRIMERGY TX1310 M1 with CentOS 7.0 (x86_64)

Installation and Operational Checking Results with conf


PRIMERGY TX1310 M1 CentOS 7.0 (x86_64) 3.10.0-123.el7.x86_64
No. Item checked Result
1 Is there HDD/RAID driver support? (OS standard or special) Special (*1)
2 Is there LAN driver support? (OS standard or special) OS Standard
3 Is installation possible in the verification machine? OK
4 Is reboot possible after installation, and does the OS start correctly? OK
5 Can the GUI be used? OK
6 Can the keyboard be used? OK
7 Can the mouse be used? OK
8 After OS start, is login as a root user possible? OK
9 Can a USB stick disk be used? -
10 Can the CD/DVD-ROM drive be used? OK
11 When logged in as a root user, does the “shutdown -h now” command perform shutdown? OK
12 Confirmation of write to local disk (write, delete, etc.) OK
13 Are the values set during installation displayed correctly (ip command)? OK
14 Can a ping be sent from the verification machine to another PC? OK
15 Can a ping be sent to the verification machine from another PC? OK
16 Can a network utility (ip,nmcli,nmtui, etc.) be used to change the network configuration? OK
17 Can the web service (httpd) be used? OK
18 Can the ftp service be used? OK
19 Can the nfs service be used? OK
20 Can the Network data transfer (nfs) be used? OK
21 Result of disk array management tool [ServerViewRAID] installation? OK
22 Result of server management software [ ServerView agents ] installation? -
23 Does the OS run even if the HDD on one side is removed? * Remove HDD when stopped, and then start -(*2)
24 Is login as a root user possible if the HDD on one side is removed? -(*2)
25 Can the touch command be used to write if the HDD on one side is removed? -(*2)
26 Does the OS start when restart is performed if the HDD on one side is removed? -(*2)
27 Is the RAID configuration rebuilt when the RAID on one side is put back? -(*2)
28 Is reboot possible and does the OS start correctly after RAID configuration rebuilding ends? -(*2)
29 Is login as a root user possible after RAID configuration rebuilding ends? -(*2)
30 48 hours stress test of CPU, HDD and network using cpubench, bonnie and phoronix test suite -(*2)
*1 The driver can be obtained from the following site.
URL: http://support.ts.fujitsu.com/download/index.asp
Select as follows
Product selection(manual search) : Fujitsu Server PRIMERGY -> PRIMERGY TXxxx
-> TX1310 M1 -> Red Hat Enterprise Linux -> Red Hat Enterprise Linux 7(x86_64)
-> SATA RAID -> RHDUP driver package megasr 16.01.2014.0318-1 for RHEL 7 GA
[Driver Information]
Date : 10.07.2014
Size : 0.48MB
Version : 16.01.2014.0318-1-4
Manufacturer : Fujitsu Technology Solutions

*2 Done with the corresponding Red Hat Enterprise Linux version.

Page 5 of 31 www.fujitsu.com/primergy
Test Report PRIMERGY TX1310 M1 with CentOS 2015-01-30

■ Installation procedure

1. After DVD boot, select [Install CentOS 7] and press Tab.


2. Add [inst.dd] option to boot option
3. Load the driver “megasr”
4. Follow usual procedure for remainder of install.
5. The relevant Server Management Software (ServerView) including manuals are located on the Fujitsu download site of the respective
server for the corresponding Red Hat Enterprise Linux version.
Reference: http://support.ts.fujitsu.com/download/index.asp

Page 6 of 31 www.fujitsu.com/primergy
Test Report PRIMERGY TX1310 M1 with CentOS 2015-01-30

PRIMERGY TX1310 M1 with CentOS 6.6 (x86)

Installation and Operational Checking Results with conf


PRIMERGY TX1310 M1 CentOS 6.6 (x86) 2.6.32-504.el6.i686
No. Item checked Result
1 Is there HDD/RAID driver support? (OS standard or special) Special (*1)
2 Is there LAN driver support? (OS standard or special) OS Standard
3 Is installation possible in the verification machine? OK
4 Is reboot possible after installation, and does the OS start correctly? OK
5 Can the GUI be used? OK
6 Can the keyboard be used? OK
7 Can the mouse be used? OK
8 After OS start, is login as a root user possible? OK
9 Can a USB stick disk be used? -
10 Can the CD/DVD-ROM drive be used? OK
11 When logged in as a root user, does the “shutdown -h now” command perform shutdown? OK
12 Confirmation of write to local disk (write, delete, etc.) OK
13 Are the values set during installation displayed correctly (ifconfig command)? OK
14 Can a ping be sent from the verification machine to another PC? OK
15 Can a ping be sent to the verification machine from another PC? OK
16 Can a network utility (system-config-network*, etc.) be used to change the network configuration? OK
17 Can the web service (httpd) be used? OK
18 Can the ftp service be used? OK
19 Can the nfs service be used? OK
20 Can the Network data transfer (nfs) be used? OK
21 Result of disk array management tool [ServerViewRAID] installation? OK
22 Result of server management software [ ServerView agents ] installation? OK
23 Does the OS run even if the HDD on one side is removed? * Remove HDD when stopped, and then start -(*2)
24 Is login as a root user possible if the HDD on one side is removed? -(*2)
25 Can the touch command be used to write if the HDD on one side is removed? -(*2)
26 Does the OS start when restart is performed if the HDD on one side is removed? -(*2)
27 Is the RAID configuration rebuilt when the RAID on one side is put back? -(*2)
28 Is reboot possible and does the OS start correctly after RAID configuration rebuilding ends? -(*2)
29 Is login as a root user possible after RAID configuration rebuilding ends? -(*2)
30 48 hours stress test of CPU, HDD and network using cpubench, bonnie and phoronix test suite -(*2)
*1 The driver can be obtained from the following site.
URL: http://support.ts.fujitsu.com/download/index.asp
Select as follows
Product selection(manually search) : Fujitsu Server PRIMERGY -> PRIMERGY TXxxx
-> TX1310 M1 -> Red Hat Enterprise Linux -> Red Hat Enterprise Linux 6(x86)
-> SATA RAID -> RHDUP driver package megasr 16.01.2014.0318-1 for RHEL6.6
[Driver Information]
Date : 02.10.2014
Size : 0.87MB
Version : 16.01.2014.0318-1-5
Manufacturer : Fujitsu Technology Solutions

*2 Done with the corresponding Red Hat Enterprise Linux version.

Page 7 of 31 www.fujitsu.com/primergy
Test Report PRIMERGY TX1310 M1 with CentOS 2015-01-30

■ Installation procedure

1. After DVD boot, select [Install or upgrade an existing system] and press Tab.
2. Add [dd] option to boot option
3. Load the driver “megasr”
4. Follow usual procedure for remainder of install.
5. The relevant Server Management Software (ServerView) including manuals are located on the Fujitsu download site of the respective
server for the corresponding Red Hat Enterprise Linux version.
Reference: http://support.ts.fujitsu.com/download/index.asp

Page 8 of 31 www.fujitsu.com/primergy
Test Report PRIMERGY TX1310 M1 with CentOS 2015-01-30

PRIMERGY TX1310 M1 with CentOS 6.6 (x86_64)

Installation and Operational Checking Results with conf


PRIMERGY TX1310 M1 CentOS 6.6 (x86) 2.6.32-504.el6.x86_64
No. Item checked Result
1 Is there HDD/RAID driver support? (OS standard or special) Special (*1)
2 Is there LAN driver support? (OS standard or special) OS Standard
3 Is installation possible in the verification machine? OK
4 Is reboot possible after installation, and does the OS start correctly? OK
5 Can the GUI be used? OK
6 Can the keyboard be used? OK
7 Can the mouse be used? OK
8 After OS start, is login as a root user possible? OK
9 Can a USB stick disk be used? -
10 Can the CD/DVD-ROM drive be used? OK
11 When logged in as a root user, does the “shutdown -h now” command perform shutdown? OK
12 Confirmation of write to local disk (write, delete, etc.) OK
13 Are the values set during installation displayed correctly (ifconfig command)? OK
14 Can a ping be sent from the verification machine to another PC? OK
15 Can a ping be sent to the verification machine from another PC? OK
16 Can a network utility (system-config-network*, etc.) be used to change the network configuration? OK
17 Can the web service (httpd) be used? OK
18 Can the ftp service be used? OK
19 Can the nfs service be used? OK
20 Can the Network data transfer (nfs) be used? OK
21 Result of disk array management tool [ServerViewRAID] installation? OK
22 Result of server management software [ ServerView agents ] installation? OK
23 Does the OS run even if the HDD on one side is removed? * Remove HDD when stopped, and then start -(*2)
24 Is login as a root user possible if the HDD on one side is removed? -(*2)
25 Can the touch command be used to write if the HDD on one side is removed? -(*2)
26 Does the OS start when restart is performed if the HDD on one side is removed? -(*2)
27 Is the RAID configuration rebuilt when the RAID on one side is put back? -(*2)
28 Is reboot possible and does the OS start correctly after RAID configuration rebuilding ends? -(*2)
29 Is login as a root user possible after RAID configuration rebuilding ends? -(*2)
30 48 hours stress test of CPU, HDD and network using cpubench, bonnie and phoronix test suite -(*2)
*1 The driver can be obtained from the following site.
URL: http://support.ts.fujitsu.com/download/index.asp
Select as follows
Product selection(manually search) : Fujitsu Server PRIMERGY -> PRIMERGY TXxxx
-> TX1310 M1 -> Red Hat Enterprise Linux -> Red Hat Enterprise Linux 6(x86_64)
-> SATA RAID -> RHDUP driver package megasr 16.01.2014.0318-1 for RHEL6.6
[Driver Information]
Date : 02.10.2014
Size : 0.87MB
Version : 16.01.2014.0318-1-5
Manufacturer : Fujitsu Technology Solutions

*2 Done with the corresponding Red Hat Enterprise Linux version.

Page 9 of 31 www.fujitsu.com/primergy
Test Report PRIMERGY TX1310 M1 with CentOS 2015-01-30

■ Installation procedure

1. After DVD boot, select [Install or upgrade an existing system] and press Tab.
2. Add [dd] option to boot option
3. Load the driver “megasr”
4. Follow usual procedure for remainder of install.
5. The relevant Server Management Software (ServerView) including manuals are located on the Fujitsu download site of the respective
server for the corresponding Red Hat Enterprise Linux version.
Reference: http://support.ts.fujitsu.com/download/index.asp

Page 10 of 31 www.fujitsu.com/primergy
Test Report PRIMERGY TX1310 M1 with CentOS 2015-01-30

PRIMERGY TX1310 M1 with CentOS 6.5 (x86)

Installation and Operational Checking Results with conf


PRIMERGY TX1310 M1 CentOS 6.5 (x86) 2.6.32-431.el6.i686
No. Item checked Result
1 Is there HDD/RAID driver support? (OS standard or special) Special (*1)
2 Is there LAN driver support? (OS standard or special) OS Standard
3 Is installation possible in the verification machine? OK
4 Is reboot possible after installation, and does the OS start correctly? OK
5 Can the GUI be used? OK
6 Can the keyboard be used? OK
7 Can the mouse be used? OK
8 After OS start, is login as a root user possible? OK
9 Can a USB stick disk be used? -
10 Can the CD/DVD-ROM drive be used? OK
11 When logged in as a root user, does the “shutdown -h now” command perform shutdown? OK
12 Confirmation of write to local disk (write, delete, etc.) OK
13 Are the values set during installation displayed correctly (ifconfig command)? OK
14 Can a ping be sent from the verification machine to another PC? OK
15 Can a ping be sent to the verification machine from another PC? OK
16 Can a network utility (system-config-network*, etc.) be used to change the network configuration? OK
17 Can the web service (httpd) be used? OK
18 Can the ftp service be used? OK
19 Can the nfs service be used? OK
20 Can the Network data transfer (nfs) be used? OK
21 Result of disk array management tool [ServerViewRAID] installation? OK
22 Result of server management software [ ServerView agents ] installation? OK
23 Does the OS run even if the HDD on one side is removed? * Remove HDD when stopped, and then start -(*2)
24 Is login as a root user possible if the HDD on one side is removed? -(*2)
25 Can the touch command be used to write if the HDD on one side is removed? -(*2)
26 Does the OS start when restart is performed if the HDD on one side is removed? -(*2)
27 Is the RAID configuration rebuilt when the RAID on one side is put back? -(*2)
28 Is reboot possible and does the OS start correctly after RAID configuration rebuilding ends? -(*2)
29 Is login as a root user possible after RAID configuration rebuilding ends? -(*2)
30 48 hours stress test of CPU, HDD and network using cpubench, bonnie and phoronix test suite -(*2)
*1 The driver can be obtained from the following site.
URL: http://support.ts.fujitsu.com/download/index.asp
Select as follows
Product selection(manual search) : Industry standard servers PRIMERGY -> PRIMERGY TXxxx
-> TX1310 M1 -> Red Hat Enterprise Linux -> Red Hat Enterprise Linux 6(x86)
-> SATA RAID -> RHDUP driver package megasr 15.02.2013.0425-1 for RHEL6.5
[Driver Information]
Date : 21.11.2013
Size : 0.86MB
Version : 15.02.2013.0425-1-5
Manufacturer : Fujitsu Technology Solutions

*2 Done with the corresponding Red Hat Enterprise Linux version.

Page 11 of 31 www.fujitsu.com/primergy
Test Report PRIMERGY TX1310 M1 with CentOS 2015-01-30

■ Installation procedure

1. After DVD boot, select [Install or upgrade an existing system] and press Tab.
2. Add [dd] option to boot option
3. Load the driver “megasr”
4. Follow usual procedure for remainder of install.
5. The relevant Server Management Software (ServerView) including manuals are located on the Fujitsu download site of the respective
server for the corresponding Red Hat Enterprise Linux version.
Reference: http://support.ts.fujitsu.com/download/index.asp

Page 12 of 31 www.fujitsu.com/primergy
Test Report PRIMERGY TX1310 M1 with CentOS 2015-01-30

PRIMERGY TX1310 M1 with CentOS 6.5 (x86_64)

Installation and Operational Checking Results with conf


PRIMERGY TX1310 M1 CentOS 6.5 (x86) 2.6.32-431.el6.x86_64
No. Item checked Result
1 Is there HDD/RAID driver support? (OS standard or special) Special (*1)
2 Is there LAN driver support? (OS standard or special) OS Standard
3 Is installation possible in the verification machine? OK
4 Is reboot possible after installation, and does the OS start correctly? OK
5 Can the GUI be used? OK
6 Can the keyboard be used? OK
7 Can the mouse be used? OK
8 After OS start, is login as a root user possible? OK
9 Can a USB stick disk be used? -
10 Can the CD/DVD-ROM drive be used? OK
11 When logged in as a root user, does the “shutdown -h now” command perform shutdown? OK
12 Confirmation of write to local disk (write, delete, etc.) OK
13 Are the values set during installation displayed correctly (ifconfig command)? OK
14 Can a ping be sent from the verification machine to another PC? OK
15 Can a ping be sent to the verification machine from another PC? OK
16 Can a network utility (system-config-network*, etc.) be used to change the network configuration? OK
17 Can the web service (httpd) be used? OK
18 Can the ftp service be used? OK
19 Can the nfs service be used? OK
20 Can the Network data transfer (nfs) be used? OK
21 Result of disk array management tool [ServerViewRAID] installation? OK
22 Result of server management software [ ServerView agents ] installation? OK
23 Does the OS run even if the HDD on one side is removed? * Remove HDD when stopped, and then start -(*2)
24 Is login as a root user possible if the HDD on one side is removed? -(*2)
25 Can the touch command be used to write if the HDD on one side is removed? -(*2)
26 Does the OS start when restart is performed if the HDD on one side is removed? -(*2)
27 Is the RAID configuration rebuilt when the RAID on one side is put back? -(*2)
28 Is reboot possible and does the OS start correctly after RAID configuration rebuilding ends? -(*2)
29 Is login as a root user possible after RAID configuration rebuilding ends? -(*2)
30 48 hours stress test of CPU, HDD and network using cpubench, bonnie and phoronix test suite -(*2)
*1 The driver can be obtained from the following site.
URL: http://support.ts.fujitsu.com/download/index.asp
Select as follows
Product selection(manual search) : Industry standard servers PRIMERGY -> PRIMERGY TXxxx
-> TX1310 M1 -> Red Hat Enterprise Linux -> Red Hat Enterprise Linux 6(x86_64)
-> SATA RAID -> RHDUP driver package megasr 15.02.2013.0425-1 for RHEL6.5
[Driver Information]
Date : 21.11.2013
Size : 0.86MB
Version : 15.02.2013.0425-1-5
Manufacturer : Fujitsu Technology Solutions

*2 Done with the corresponding Red Hat Enterprise Linux version.

Page 13 of 31 www.fujitsu.com/primergy
Test Report PRIMERGY TX1310 M1 with CentOS 2015-01-30

■ Installation procedure

1. After DVD boot, select [Install or upgrade an existing system] and press Tab.
2. Add [dd] option to boot option
3. Load the driver “megasr”
4. Follow usual procedure for remainder of install.
5. The relevant Server Management Software (ServerView) including manuals are located on the Fujitsu download site of the respective
server for the corresponding Red Hat Enterprise Linux version.
Reference: http://support.ts.fujitsu.com/download/index.asp

Page 14 of 31 www.fujitsu.com/primergy
Test Report PRIMERGY TX1310 M1 with CentOS 2015-01-30

PRIMERGY TX1310 M1 with CentOS 6.4 (x86)

Installation and Operational Checking Results with conf


PRIMERGY TX1310 M1 CentOS 6.4 (x86) 2.6.32-358.el6.i686
No. Item checked Result
1 Is there HDD/RAID driver support? (OS standard or special) Special (*1)
2 Is there LAN driver support? (OS standard or special) OS Standard
3 Is installation possible in the verification machine? OK
4 Is reboot possible after installation, and does the OS start correctly? OK
5 Can the GUI be used? OK
6 Can the keyboard be used? OK
7 Can the mouse be used? OK
8 After OS start, is login as a root user possible? OK
9 Can a USB stick disk be used? -
10 Can the CD/DVD-ROM drive be used? OK
11 When logged in as a root user, does the “shutdown -h now” command perform shutdown? OK
12 Confirmation of write to local disk (write, delete, etc.) OK
13 Are the values set during installation displayed correctly (ifconfig command)? OK
14 Can a ping be sent from the verification machine to another PC? OK
15 Can a ping be sent to the verification machine from another PC? OK
16 Can a network utility (system-config-network*, etc.) be used to change the network configuration? OK
17 Can the web service (httpd) be used? OK
18 Can the ftp service be used? OK
19 Can the nfs service be used? OK
20 Can the Network data transfer (nfs) be used? OK
21 Result of disk array management tool [ServerViewRAID] installation? OK
22 Result of server management software [ ServerView agents ] installation? OK
23 Does the OS run even if the HDD on one side is removed? * Remove HDD when stopped, and then start -(*2)
24 Is login as a root user possible if the HDD on one side is removed? -(*2)
25 Can the touch command be used to write if the HDD on one side is removed? -(*2)
26 Does the OS start when restart is performed if the HDD on one side is removed? -(*2)
27 Is the RAID configuration rebuilt when the RAID on one side is put back? -(*2)
28 Is reboot possible and does the OS start correctly after RAID configuration rebuilding ends? -(*2)
29 Is login as a root user possible after RAID configuration rebuilding ends? -(*2)
30 48 hours stress test of CPU, HDD and network using cpubench, bonnie and phoronix test suite -(*2)
*1 The driver can be obtained from the following site.
URL: http://support.ts.fujitsu.com/download/index.asp
Select as follows
Product selection(manual search) : Industry standard servers PRIMERGY -> PRIMERGY TXxxx
-> TX1310 M1 -> Red Hat Enterprise Linux -> Red Hat Enterprise Linux 6(x86)
-> SATA RAID -> RHDUP driver package megasr 15.02.2013.0425-1 for RHEL6.4
[Driver Information]
Date : 30.04. 2013
Size : 0.88MB
Version : 15.02.2013.0425-1-5
Manufacturer : Fujitsu Technology Solutions

*2 Done with the corresponding Red Hat Enterprise Linux version.

Page 15 of 31 www.fujitsu.com/primergy
Test Report PRIMERGY TX1310 M1 with CentOS 2015-01-30

■ Installation procedure

1. After DVD boot, select [Install or upgrade an existing system] and press Tab.
2. Add [dd] option to boot option
3. Load the driver “megasr”
4. Follow usual procedure for remainder of install.
5. The relevant Server Management Software (ServerView) including manuals are located on the Fujitsu download site of the respective
server for the corresponding Red Hat Enterprise Linux version.
Reference: http://support.ts.fujitsu.com/download/index.asp

Page 16 of 31 www.fujitsu.com/primergy
Test Report PRIMERGY TX1310 M1 with CentOS 2015-01-30

PRIMERGY TX1310 M1 with CentOS 6.4 (x86_64)

Installation and Operational Checking Results with conf


PRIMERGY TX1310 M1 CentOS 6.4 (x86) 2.6.32-358.el6.x86_64
No. Item checked Result
1 Is there HDD/RAID driver support? (OS standard or special) Special (*1)
2 Is there LAN driver support? (OS standard or special) OS Standard
3 Is installation possible in the verification machine? OK
4 Is reboot possible after installation, and does the OS start correctly? OK
5 Can the GUI be used? OK
6 Can the keyboard be used? OK
7 Can the mouse be used? OK
8 After OS start, is login as a root user possible? OK
9 Can a USB stick disk be used? -
10 Can the CD/DVD-ROM drive be used? OK
11 When logged in as a root user, does the “shutdown -h now” command perform shutdown? OK
12 Confirmation of write to local disk (write, delete, etc.) OK
13 Are the values set during installation displayed correctly (ifconfig command)? OK
14 Can a ping be sent from the verification machine to another PC? OK
15 Can a ping be sent to the verification machine from another PC? OK
16 Can a network utility (system-config-network*, etc.) be used to change the network configuration? OK
17 Can the web service (httpd) be used? OK
18 Can the ftp service be used? OK
19 Can the nfs service be used? OK
20 Can the Network data transfer (nfs) be used? OK
21 Result of disk array management tool [ServerViewRAID] installation? OK
22 Result of server management software [ ServerView agents ] installation? OK
23 Does the OS run even if the HDD on one side is removed? * Remove HDD when stopped, and then start -(*2)
24 Is login as a root user possible if the HDD on one side is removed? -(*2)
25 Can the touch command be used to write if the HDD on one side is removed? -(*2)
26 Does the OS start when restart is performed if the HDD on one side is removed? -(*2)
27 Is the RAID configuration rebuilt when the RAID on one side is put back? -(*2)
28 Is reboot possible and does the OS start correctly after RAID configuration rebuilding ends? -(*2)
29 Is login as a root user possible after RAID configuration rebuilding ends? -(*2)
30 48 hours stress test of CPU, HDD and network using cpubench, bonnie and phoronix test suite -(*2)
*1 The driver can be obtained from the following site.
URL: http://support.ts.fujitsu.com/download/index.asp
Select as follows
Product selection(manual search) : Industry standard servers PRIMERGY -> PRIMERGY TXxxx
-> TX1310 M1 -> Red Hat Enterprise Linux -> Red Hat Enterprise Linux 6(x86_64)
-> SATA RAID -> RHDUP driver package megasr 15.02.2013.0425-1 for RHEL6.4
[Driver Information]
Date : 30.04. 2013
Size : 0.88MB
Version : 15.02.2013.0425-1-5
Manufacturer : Fujitsu Technology Solutions

*2 Done with the corresponding Red Hat Enterprise Linux version.

Page 17 of 31 www.fujitsu.com/primergy
Test Report PRIMERGY TX1310 M1 with CentOS 2015-01-30

■ Installation procedure

1. After DVD boot, select [Install or upgrade an existing system] and press Tab.
2. Add [dd] option to boot option
3. Load the driver “megasr”
4. Follow usual procedure for remainder of install.
5. The relevant Server Management Software (ServerView) including manuals are located on the Fujitsu download site of the respective
server for the corresponding Red Hat Enterprise Linux version.
Reference: http://support.ts.fujitsu.com/download/index.asp

Page 18 of 31 www.fujitsu.com/primergy
Test Report PRIMERGY TX1310 M1 with CentOS 2015-01-30

PRIMERGY TX1310 M1 with CentOS 5.11 (x86)

Installation and Operational Checking Results with conf


PRIMERGY TX1310 M1 CentOS 5.11 (x86) 2.6.18-398.el5PAE
No. Item checked Result
1 Is there HDD/RAID driver support? (OS standard or special) Special (*1)
2 Is there LAN driver support? (OS standard or special) OS Standard
3 Is installation possible in the verification machine? OK
4 Is reboot possible after installation, and does the OS start correctly? OK
5 Can the GUI be used? OK
6 Can the keyboard be used? OK
7 Can the mouse be used? OK
8 After OS start, is login as a root user possible? OK
9 Can a USB stick disk be used? -
10 Can the CD/DVD-ROM drive be used? OK
11 When logged in as a root user, does the “shutdown -h now” command perform shutdown? OK
12 Confirmation of write to local disk (write, delete, etc.) OK
13 Are the values set during installation displayed correctly (ifconfig command)? OK
14 Can a ping be sent from the verification machine to another PC? OK
15 Can a ping be sent to the verification machine from another PC? OK
16 Can a network utility (system-config-network*, etc.) be used to change the network configuration? OK
17 Can the web service (httpd) be used? OK
18 Can the ftp service be used? OK
19 Can the nfs service be used? OK
20 Can the Network data transfer (nfs) be used? OK
21 Result of disk array management tool [ServerViewRAID] installation? OK
22 Result of server management software [ ServerView agents ] installation? OK
23 Does the OS run even if the HDD on one side is removed? * Remove HDD when stopped, and then start -(*2)
24 Is login as a root user possible if the HDD on one side is removed? -(*2)
25 Can the touch command be used to write if the HDD on one side is removed? -(*2)
26 Does the OS start when restart is performed if the HDD on one side is removed? -(*2)
27 Is the RAID configuration rebuilt when the RAID on one side is put back? -(*2)
28 Is reboot possible and does the OS start correctly after RAID configuration rebuilding ends? -(*2)
29 Is login as a root user possible after RAID configuration rebuilding ends? -(*2)
30 48 hours stress test of CPU, HDD and network using cpubench, bonnie and phoronix test suite -(*2)
*1 The driver can be obtained from the following site.
URL: http://support.ts.fujitsu.com/download/index.asp
Select as follows
Product selection(manual search) : Fujitsu Server PRIMERGY -> PRIMERGY TXxxx
-> TX1310 M1 -> Red Hat Enterprise Linux -> Red Hat Enterprise Linux 5(x86)
-> SATA RAID -> RHDUP driver package megasr 16.01.2014.0318-1 for RHEL5.11
[Driver Information]
Date : 05.09.2014
Size : 3.29MB
Version : 16.01.2014.0318-1-9
Manufacturer : Fujitsu Technology Solutions

*2 Done with the corresponding Red Hat Enterprise Linux version.

Page 19 of 31 www.fujitsu.com/primergy
Test Report PRIMERGY TX1310 M1 with CentOS 2015-01-30

■ Installation procedure

1. After [Boot:] prompt appears, type “linux dd” then press Enter
2. Load the driver “megasr”
3. Follow usual procedure for remainder of install.
4. The relevant Server Management Software (ServerView) including manuals are located on the Fujitsu download site of the respective
server for the corresponding Red Hat Enterprise Linux version.
Reference: http://support.ts.fujitsu.com/download/index.asp

Page 20 of 31 www.fujitsu.com/primergy
Test Report PRIMERGY TX1310 M1 with CentOS 2015-01-30

PRIMERGY TX1310 M1 with CentOS 5.11 (x86_64)

Installation and Operational Checking Results with conf


PRIMERGY TX1310 M1 CentOS 5.11 (x86_64) 2.6.18-398.el5
No. Item checked Result
1 Is there HDD/RAID driver support? (OS standard or special) Special (*1)
2 Is there LAN driver support? (OS standard or special) OS Standard
3 Is installation possible in the verification machine? OK
4 Is reboot possible after installation, and does the OS start correctly? OK
5 Can the GUI be used? OK
6 Can the keyboard be used? OK
7 Can the mouse be used? OK
8 After OS start, is login as a root user possible? OK
9 Can a USB stick disk be used? -
10 Can the CD/DVD-ROM drive be used? OK
11 When logged in as a root user, does the “shutdown -h now” command perform shutdown? OK
12 Confirmation of write to local disk (write, delete, etc.) OK
13 Are the values set during installation displayed correctly (ifconfig command)? OK
14 Can a ping be sent from the verification machine to another PC? OK
15 Can a ping be sent to the verification machine from another PC? OK
16 Can a network utility (system-config-network*, etc.) be used to change the network configuration? OK
17 Can the web service (httpd) be used? OK
18 Can the ftp service be used? OK
19 Can the nfs service be used? OK
20 Can the Network data transfer (nfs) be used? OK
21 Result of disk array management tool [ServerViewRAID] installation? OK
22 Result of server management software [ ServerView agents ] installation? OK
23 Does the OS run even if the HDD on one side is removed? * Remove HDD when stopped, and then start -(*2)
24 Is login as a root user possible if the HDD on one side is removed? -(*2)
25 Can the touch command be used to write if the HDD on one side is removed? -(*2)
26 Does the OS start when restart is performed if the HDD on one side is removed? -(*2)
27 Is the RAID configuration rebuilt when the RAID on one side is put back? -(*2)
28 Is reboot possible and does the OS start correctly after RAID configuration rebuilding ends? -(*2)
29 Is login as a root user possible after RAID configuration rebuilding ends? -(*2)
30 48 hours stress test of CPU, HDD and network using cpubench, bonnie and phoronix test suite -(*2)
*1 The driver can be obtained from the following site.
URL: http://support.ts.fujitsu.com/download/index.asp
Select as follows
Product selection(manual search) : Fujitsu Server PRIMERGY -> PRIMERGY TXxxx
-> TX1310 M1 -> Red Hat Enterprise Linux -> Red Hat Enterprise Linux 5(x86_64)
-> SATA RAID -> RHDUP driver package megasr 16.01.2014.0318-1 for RHEL5.11
[Driver Information]
Date : 05.09.2014
Size : 3.29MB
Version : 16.01.2014.0318-1-9
Manufacturer : Fujitsu Technology Solutions

*2 Done with the corresponding Red Hat Enterprise Linux version.

Page 21 of 31 www.fujitsu.com/primergy
Test Report PRIMERGY TX1310 M1 with CentOS 2015-01-30

■ Installation procedure

1. After [Boot:] prompt appears, type “linux dd” then press Enter
2. Load the driver “megasr”
3. Follow usual procedure for remainder of install.
4. The relevant Server Management Software (ServerView) including manuals are located on the Fujitsu download site of the respective
server for the corresponding Red Hat Enterprise Linux version.
Reference: http://support.ts.fujitsu.com/download/index.asp

Page 22 of 31 www.fujitsu.com/primergy
Test Report PRIMERGY TX1310 M1 with CentOS 2015-01-30

PRIMERGY TX1310 M1 with CentOS 5.10 (x86)

Installation and Operational Checking Results with conf


PRIMERGY TX1310 M1 CentOS 5.10 (x86) 2.6.18-371.el5PAE
No. Item checked Result
1 Is there HDD/RAID driver support? (OS standard or special) Special (*1)
2 Is there LAN driver support? (OS standard or special) OS Standard
3 Is installation possible in the verification machine? OK
4 Is reboot possible after installation, and does the OS start correctly? OK
5 Can the GUI be used? OK
6 Can the keyboard be used? OK
7 Can the mouse be used? OK
8 After OS start, is login as a root user possible? OK
9 Can a USB stick disk be used? -
10 Can the CD/DVD-ROM drive be used? OK
11 When logged in as a root user, does the “shutdown -h now” command perform shutdown? OK
12 Confirmation of write to local disk (write, delete, etc.) OK
13 Are the values set during installation displayed correctly (ifconfig command)? OK
14 Can a ping be sent from the verification machine to another PC? OK
15 Can a ping be sent to the verification machine from another PC? OK
16 Can a network utility (system-config-network*, etc.) be used to change the network configuration? OK
17 Can the web service (httpd) be used? OK
18 Can the ftp service be used? OK
19 Can the nfs service be used? OK
20 Can the Network data transfer (nfs) be used? OK
21 Result of disk array management tool [ServerViewRAID] installation? OK
22 Result of server management software [ ServerView agents ] installation? OK
23 Does the OS run even if the HDD on one side is removed? * Remove HDD when stopped, and then start -(*2)
24 Is login as a root user possible if the HDD on one side is removed? -(*2)
25 Can the touch command be used to write if the HDD on one side is removed? -(*2)
26 Does the OS start when restart is performed if the HDD on one side is removed? -(*2)
27 Is the RAID configuration rebuilt when the RAID on one side is put back? -(*2)
28 Is reboot possible and does the OS start correctly after RAID configuration rebuilding ends? -(*2)
29 Is login as a root user possible after RAID configuration rebuilding ends? -(*2)
30 48 hours stress test of CPU, HDD and network using cpubench, bonnie and phoronix test suite -(*2)
*1 The driver can be obtained from the following site.
URL: http://support.ts.fujitsu.com/download/index.asp
Select as follows
Product selection(manual search) : Industry standard servers PRIMERGY -> PRIMERGY TXxxx
-> TX1310 M1 -> Red Hat Enterprise Linux -> Red Hat Enterprise Linux 5(x86)
-> SATA RAID -> RHDUP driver package megasr 15.02.2013.0425-1 for RHEL5.10
[Driver Information]
Date : 18.09.2013
Size : 2.04MB
Version : 15.02.2013.0425-1-5
Manufacturer : Fujitsu Technology Solutions

*2 Done with the corresponding Red Hat Enterprise Linux version.

Page 23 of 31 www.fujitsu.com/primergy
Test Report PRIMERGY TX1310 M1 with CentOS 2015-01-30

■ Installation procedure

1. After [Boot:] prompt appears, type “linux dd” then press Enter
2. Load the driver “megasr”
3. Follow usual procedure for remainder of install.
4. The relevant Server Management Software (ServerView) including manuals are located on the Fujitsu download site of the respective
server for the corresponding Red Hat Enterprise Linux version.
Reference: http://support.ts.fujitsu.com/download/index.asp

Page 24 of 31 www.fujitsu.com/primergy
Test Report PRIMERGY TX1310 M1 with CentOS 2015-01-30

PRIMERGY TX1310 M1 with CentOS 5.10 (x86_64)

Installation and Operational Checking Results with conf


PRIMERGY TX1310 M1 CentOS 5.10 (x86_64) 2.6.18-371.el5
No. Item checked Result
1 Is there HDD/RAID driver support? (OS standard or special) Special (*1)
2 Is there LAN driver support? (OS standard or special) OS Standard
3 Is installation possible in the verification machine? OK
4 Is reboot possible after installation, and does the OS start correctly? OK
5 Can the GUI be used? OK
6 Can the keyboard be used? OK
7 Can the mouse be used? OK
8 After OS start, is login as a root user possible? OK
9 Can a USB stick disk be used? -
10 Can the CD/DVD-ROM drive be used? OK
11 When logged in as a root user, does the “shutdown -h now” command perform shutdown? OK
12 Confirmation of write to local disk (write, delete, etc.) OK
13 Are the values set during installation displayed correctly (ifconfig command)? OK
14 Can a ping be sent from the verification machine to another PC? OK
15 Can a ping be sent to the verification machine from another PC? OK
16 Can a network utility (system-config-network*, etc.) be used to change the network configuration? OK
17 Can the web service (httpd) be used? OK
18 Can the ftp service be used? OK
19 Can the nfs service be used? OK
20 Can the Network data transfer (nfs) be used? OK
21 Result of disk array management tool [ServerViewRAID] installation? OK
22 Result of server management software [ ServerView agents ] installation? OK
23 Does the OS run even if the HDD on one side is removed? * Remove HDD when stopped, and then start -(*2)
24 Is login as a root user possible if the HDD on one side is removed? -(*2)
25 Can the touch command be used to write if the HDD on one side is removed? -(*2)
26 Does the OS start when restart is performed if the HDD on one side is removed? -(*2)
27 Is the RAID configuration rebuilt when the RAID on one side is put back? -(*2)
28 Is reboot possible and does the OS start correctly after RAID configuration rebuilding ends? -(*2)
29 Is login as a root user possible after RAID configuration rebuilding ends? -(*2)
30 48 hours stress test of CPU, HDD and network using cpubench, bonnie and phoronix test suite -(*2)
*1 The driver can be obtained from the following site.
URL: http://support.ts.fujitsu.com/download/index.asp
Select as follows
Product selection(manual search) : Industry standard servers PRIMERGY -> PRIMERGY TXxxx
-> TX1310 M1 -> Red Hat Enterprise Linux -> Red Hat Enterprise Linux 5(x86_64)
-> SATA RAID -> RHDUP driver package megasr 15.02.2013.0425-1 for RHEL5.10
[Driver Information]
Date : 18.09.2013
Size : 2.04MB
Version : 15.02.2013.0425-1-5
Manufacturer : Fujitsu Technology Solutions

*2 Done with the corresponding Red Hat Enterprise Linux version.

Page 25 of 31 www.fujitsu.com/primergy
Test Report PRIMERGY TX1310 M1 with CentOS 2015-01-30

■ Installation procedure

1. After [Boot:] prompt appears, type “linux dd” then press Enter
2. Load the driver “megasr”
3. Follow usual procedure for remainder of install.
4. The relevant Server Management Software (ServerView) including manuals are located on the Fujitsu download site of the respective
server for the corresponding Red Hat Enterprise Linux version.
Reference: http://support.ts.fujitsu.com/download/index.asp

Page 26 of 31 www.fujitsu.com/primergy
Test Report PRIMERGY TX1310 M1 with CentOS 2015-01-30

PRIMERGY TX1310 M1 with CentOS 5.9 (x86)

Installation and Operational Checking Results with conf


PRIMERGY TX1310 M1 CentOS 5.9 (x86) 2.6.18-348.el5PAE
No. Item checked Result
1 Is there HDD/RAID driver support? (OS standard or special) Special (*1)
2 Is there LAN driver support? (OS standard or special) OS Standard
3 Is installation possible in the verification machine? OK
4 Is reboot possible after installation, and does the OS start correctly? OK
5 Can the GUI be used? OK
6 Can the keyboard be used? OK
7 Can the mouse be used? OK
8 After OS start, is login as a root user possible? OK
9 Can a USB stick disk be used? -
10 Can the CD/DVD-ROM drive be used? OK
11 When logged in as a root user, does the “shutdown -h now” command perform shutdown? OK
12 Confirmation of write to local disk (write, delete, etc.) OK
13 Are the values set during installation displayed correctly (ifconfig command)? OK
14 Can a ping be sent from the verification machine to another PC? OK
15 Can a ping be sent to the verification machine from another PC? OK
16 Can a network utility (system-config-network*, etc.) be used to change the network configuration? OK
17 Can the web service (httpd) be used? OK
18 Can the ftp service be used? OK
19 Can the nfs service be used? OK
20 Can the Network data transfer (nfs) be used? OK
21 Result of disk array management tool [ServerViewRAID] installation? OK
22 Result of server management software [ ServerView agents ] installation? OK
23 Does the OS run even if the HDD on one side is removed? * Remove HDD when stopped, and then start -(*2)
24 Is login as a root user possible if the HDD on one side is removed? -(*2)
25 Can the touch command be used to write if the HDD on one side is removed? -(*2)
26 Does the OS start when restart is performed if the HDD on one side is removed? -(*2)
27 Is the RAID configuration rebuilt when the RAID on one side is put back? -(*2)
28 Is reboot possible and does the OS start correctly after RAID configuration rebuilding ends? -(*2)
29 Is login as a root user possible after RAID configuration rebuilding ends? -(*2)
30 48 hours stress test of CPU, HDD and network using cpubench, bonnie and phoronix test suite -(*2)
*1 The driver can be obtained from the following site.
URL: http://support.ts.fujitsu.com/download/index.asp
Select as follows
Product selection(manual search) : Industry standard servers PRIMERGY -> PRIMERGY TXxxx
-> TX1310 M1 -> Red Hat Enterprise Linux -> Red Hat Enterprise Linux 5(x86)
-> SATA RAID -> RHDUP driver pacjage megasr 15.02.2013.0425-1 for RHEL5.9
[Driver Information]
Date : 30.04.2013
Size : 2.06MB
Version : 15.02.2013.0425-1
Manufacturer : Fujitsu Technology Solutions

*2 Done with the corresponding Red Hat Enterprise Linux version.

Page 27 of 31 www.fujitsu.com/primergy
Test Report PRIMERGY TX1310 M1 with CentOS 2015-01-30

■ Installation procedure

1. After [Boot:] prompt appears, type “linux dd” then press Enter
2. Load the driver “megasr”
3. Follow usual procedure for remainder of install.
4. The relevant Server Management Software (ServerView) including manuals are located on the Fujitsu download site of the respective
server for the corresponding Red Hat Enterprise Linux version.
Reference: http://support.ts.fujitsu.com/download/index.asp

Page 28 of 31 www.fujitsu.com/primergy
Test Report PRIMERGY TX1310 M1 with CentOS 2015-01-30

PRIMERGY TX1310 M1 with CentOS 5.9 (x86_64)

Installation and Operational Checking Results with conf


PRIMERGY TX1310 M1 CentOS 5.9 (x86_64) 2.6.18-348.el5
No. Item checked Result
1 Is there HDD/RAID driver support? (OS standard or special) Special (*1)
2 Is there LAN driver support? (OS standard or special) OS Standard
3 Is installation possible in the verification machine? OK
4 Is reboot possible after installation, and does the OS start correctly? OK
5 Can the GUI be used? OK
6 Can the keyboard be used? OK
7 Can the mouse be used? OK
8 After OS start, is login as a root user possible? OK
9 Can a USB stick disk be used? -
10 Can the CD/DVD-ROM drive be used? OK
11 When logged in as a root user, does the “shutdown -h now” command perform shutdown? OK
12 Confirmation of write to local disk (write, delete, etc.) OK
13 Are the values set during installation displayed correctly (ifconfig command)? OK
14 Can a ping be sent from the verification machine to another PC? OK
15 Can a ping be sent to the verification machine from another PC? OK
16 Can a network utility (system-config-network*, etc.) be used to change the network configuration? OK
17 Can the web service (httpd) be used? OK
18 Can the ftp service be used? OK
19 Can the nfs service be used? OK
20 Can the Network data transfer (nfs) be used? OK
21 Result of disk array management tool [ServerViewRAID] installation? OK
22 Result of server management software [ ServerView agents ] installation? OK
23 Does the OS run even if the HDD on one side is removed? * Remove HDD when stopped, and then start -(*2)
24 Is login as a root user possible if the HDD on one side is removed? -(*2)
25 Can the touch command be used to write if the HDD on one side is removed? -(*2)
26 Does the OS start when restart is performed if the HDD on one side is removed? -(*2)
27 Is the RAID configuration rebuilt when the RAID on one side is put back? -(*2)
28 Is reboot possible and does the OS start correctly after RAID configuration rebuilding ends? -(*2)
29 Is login as a root user possible after RAID configuration rebuilding ends? -(*2)
30 48 hours stress test of CPU, HDD and network using cpubench, bonnie and phoronix test suite -(*2)
*1 The driver can be obtained from the following site.
URL: http://support.ts.fujitsu.com/download/index.asp
Select as follows
Product selection(manual search) : Industry standard servers PRIMERGY -> PRIMERGY TXxxx
-> TX1310 M1 -> Red Hat Enterprise Linux -> Red Hat Enterprise Linux 5(x86_64)
-> SATA RAID -> RHDUP driver pacjage megasr 15.02.2013.0425-1 for RHEL5.9
[Driver Information]
Date : 30.04.2013
Size : 2.06MB
Version : 15.02.2013.0425-1
Manufacturer : Fujitsu Technology Solution

*2 Done with the corresponding Red Hat Enterprise Linux version.

Page 29 of 31 www.fujitsu.com/primergy
Test Report PRIMERGY TX1310 M1 with CentOS 2015-01-30

■ Installation procedure

1. After [Boot:] prompt appears, type “linux dd” then press Enter
2. Load the driver “megasr”
3. Follow usual procedure for remainder of install.
4. The relevant Server Management Software (ServerView) including manuals are located on the Fujitsu download site of the respective
server for the corresponding Red Hat Enterprise Linux version.
Reference: http://support.ts.fujitsu.com/download/index.asp

Page 30 of 31 www.fujitsu.com/primergy
Test Report PRIMERGY TX1310 M1 with CentOS 2015-01-30

Contact ƒ Copyright 2010 [Fujitsu company name] Fujitsu, the Fujitsu logo, [other Fujitsu trademarks /registered
FUJITSU [Company Name] trademarks] are trademarks or registered trademarks of Fujitsu Limited in Japan and other countries. Other
Address: x-xx-x, street, city, state, ZIP code, country company, product and service names may be trademarks or registered trademarks of their respective owners.
Phone: xx-xxxx-xxxx Technical data subject to modification and delivery subject to availability. Any liability that the data and
Fax : xx-xxxx-xxxx illustrations are complete, actual or correct is excluded. Designations may be trademarks and/or copyrights of
E-mail: xxx.xxxxx@xx.fujitsu.com the respective manufacturer, the use of which by third parties for their own purposes may infringe the rights of
Website: www.fujitsu.com/[Country Code] such owner. [Other disclaimers]
YYYY-MM-DD [Region Code] [Language Code]

Page 31 of 31 www.fujitsu.com/primergy

You might also like