No.

17
Boundary Line

Bedroom 01 Bedroom 02

Front Rear
Garden Garden

DN

Bedroom 03

No.17
Boundary Line

Existing First Floor Plan 1:100

Slope

Flat Roof
Slope Slope

Slope
Front Rear
Garden Garden

Slope
No.17
Boundary Line

Flat Roof
Reception Living

Front Rear
Garden Garden
Existing Roof Plan 1:100

Kitchen
UP

Out-Building

Existing Ground Floor Plan 1:100

Existing Plans Project : Proposed Loft Conversion Drawing no : 19_NG_PD_01


Issue :
Proposed Loft Conversion Address : 19 NUTFIELD GARDENS
Date : 05/01/21
ILFORD
A 05.01.21 DA ISSUE BL
ISSUE DATE AMENDMENT BY
IG3 9TB
Existing Front Elevation 1:100 Existing Side Elevation 1:100

Existing Rear Elevation 1:100 Existing Flank Elevation 1:100

Existing Elevations Project : Proposed Loft Conversion Drawing no : 19_NG_PD_02


Issue :
Proposed Loft Conversion Address : 19 NUTFIELD GARDENS
Date : 05/01/21
ILFORD
A 05.01.21 DA ISSUE BL
ISSUE DATE AMENDMENT BY
IG3 9TB
Note: All doors on to the stairway must
be FD30 rated fire doors to BS 476-
22:1987 except bathroom and toilet
doors.

No.17
Boundary Line

Reception Living
Energy Efficient
Energy Efficient Lighting
Lighting

Front Rear
Garden FD30 Garden
FD30

FD30
Energy Efficient
Lighting
SD
Kitchen
AA' UP HD AA'
Provide Mechanichal extractor hood,
60L/sec. and duct to OUTSIDE AIR

Mains Operated Smoke


Alarm System. Ensure that
the mains operated, battery
back-up, interlinked smoke
alarm system is installed in
Out-Building
accordance with BS5839:
Part 6.

Proposed Ground Floor Plan 1:50

Proposed Plan Project : Proposed Loft Conversion Drawing no : 19_NG_PD_03


Issue :
Proposed Loft Conversion Address : 19 NUTFIELD GARDENS
Date : 05/01/21
ILFORD
A 05.01.21 DA ISSUE BL
ISSUE DATE AMENDMENT BY
IG3 9TB
Note: All doors on to the stairway must
be FD30 rated fire doors to BS 476-
22:1987 except bathroom and toilet
doors.

No.17
Boundary Line

Bedroom 01 Bedroom 02
Energy Efficient Energy Efficient
Lighting Lighting

Front Rear
Garden FD30 Garden
FD30
FD30
SD
UP DN

Bedroom 03
AA' Energy Efficient
Lighting
AA'

Create new stairs


Mains Operated Smoke from First Floor to
Alarm System. Ensure that Second Floor (Loft)
the mains operated, battery Provide Mechanichal extract fan to outside
back-up, interlinked smoke air; with capacity of 30L/sec. Connect to
alarm system is installed in the lightning circuit and ensure a 15 minute
accordance with BS5839: overrun timer is fitted.
Part 6.

Proposed First Floor Plan 1:50

Proposed Plan Project : Proposed Loft Conversion Drawing no : 19_NG_PD_04


Issue :
Proposed Loft Conversion Address : 19 NUTFIELD GARDENS
Date : 05/01/21
ILFORD
A 05.01.21 DA ISSUE BL
ISSUE DATE AMENDMENT BY
IG3 9TB
All glazing in 'critical' locations (i.e below Dormer face to be set back
1500mm for doors and 800mm for by at least 200mm from
windows, to internal and external walls) is face of rear wall.
to be safety glazing. If laminate or
toughened glass is to be used it should
Note: All doors on to the stairway must be in accordance with BS6206, if to
be FD30 rated fire doors to BS 476- provide containment. This includes roof
22:1987 except bathroom and toilet lights at low level.
doors. No.17
Boundary Line

The proposed rooflights don't Juliet Balcony


protrude by more than 150mm Roof
Light

Roof light over. position to


be agreed with building Bedroom 04
inspector on site Energy Efficient
Lighting
Roof
Front Light Rear
Garden Garden

SD EN-SUITE
Energy Efficient
DN Lighting

AA' Roof
Light
AA'

Provide Mechanichal extract fan to outside


air; with capacity of 30L/sec. Connect to
the lightning circuit and ensure a 15 minute
overrun timer is fitted.
Mains Operated Smoke
Alarm System. Ensure that
the mains operated, battery
back-up, interlinked smoke
alarm system is installed in
accordance with BS5839:
Part 6.

Proposed Loft Plan 1:50

Proposed Plan Project : Proposed Loft Conversion Drawing no : 19_NG_PD_05


Issue :
Proposed Loft Conversion Address : 19 NUTFIELD GARDENS
Date : 05/01/21
ILFORD
A 05.01.21 DA ISSUE BL
ISSUE DATE AMENDMENT BY
IG3 9TB
No.17
Boundary Line

Slope

Flat Roof
Slope
Slope

Flat roof
Slope fall
Front Rear
Garden Garden

Slope

Flat Roof

Proposed Roof Plan 1:50

Proposed Plan Project : Proposed Loft Conversion Drawing no : 19_NG_PD_06


Issue :
Proposed Loft Conversion Address : 19 NUTFIELD GARDENS
Date : 05/01/21
ILFORD
A 05.01.21 DA ISSUE BL
ISSUE DATE AMENDMENT BY
IG3 9TB
Proposed Front Elevation 1:100 Proposed Side Elevation 1:100

Proposed Rear Elevation 1:100 Proposed Flank Elevation 1:100

Proposed Elevations Project : Proposed Loft Conversion Drawing no : 19_NG_PD_07


Issue :
Proposed Loft Conversion Address : 19 NUTFIELD GARDENS
Date : 05/01/21
ILFORD
A 05.01.21 DA ISSUE BL
ISSUE DATE AMENDMENT BY
IG3 9TB
GENERAL NOTES

1. DIMENSIONS
All dimensions and suitability of existing effected
walls, lintels, beams and foundations to be checked
on site prior to commencement.
3 Layers Of Felt Finished With Bitumen Bedded Contractor to check site thoroughly & reportany
Stone Chipping To a Depth of 12.5mm discrepancies.
100mm Kooltherm K7 is Required Between the Joists 2. MATERIALS
and 42.5mm Kooltherm K1 B under. 50mm Ventilated All materials & workmanship to be carried out in
Continuous Ridge Vent Air Gap Between Insulation and Plywood accordance with the relevant british standards codes
Proposed New Roof Light Above of practice, Specification & Building Regulations.
Size to be Confirmed by Client 3. PARTYWALLACT 1996etc.
with Builder Onsite. It is owner's/client's responsibility to fullfil thier duty
Flat Roof Joists
110mm Kingspan
Attic Floor 150x47 C24's under this act. Under the terms and conditions of the
Re-Inforce Ex. Rafters 100x50x10mm @400 c/c Kooltherm K7
with 150x47 C16 PFC
above act it will be necessary for a PaKywa! notice
100mm Kingapan Thermawall TW55 Between Plus
@400 c/c to be served on the adjoining neighbouring property.
22mm Gyproc Thermaline Basic Over with VCL
Fixed to Internal Face of Insulation No part of new works i.e. Foundations walls or roof
Bedroom to oversai! the boundary.
Rockwool Flexible
04 En-suite 4. CDM REGULATIONS HEALTH & SAFETY
100mm in Chickenwire It is owner's/client's responsibility to fullfil thier duty
Rockwool Flexible 100mm
Floor Joists in Chickenwire under this act. Under the terms and conditions of the
150x47 C24's above act it will be necessary for an appointment of
@400 c/c
CDM coordinator for any works lasting more than
30days.
5. VENTILATION
Habitable rooms to have minimam the floor area
openable widows / doors for ventilation windows to
habitable rooms to be fitted with trickle vents in
frames giving 8000sq mm background ventilation.
Bathroom to have mechanical extract fan providing
Bathroom Bedroom 03 30 litres per second extractrate.
6. WINDOWS / DOORS
New windows to be double glazed to suit clients
requirements. Any glazing to windows below 800mm
from floor level to be glazed with glass only to BS
6206.
7. RAIN WATER GOODS
Half round 100mm diameter P.V.C gutters and
63mm down pipe discharging to lower roof.
8. DRAIN / MANHOLES
Any drain / manholes discovered on site that are not
shown on drawings must immediately be brought to
engineer's attention.
Hall Kitchen FIRE PRECUATION WORKS
Door to second floor bedroom to be 2 hour fire
resistant with 'Perko' closer.
API other doors to stair enclosure to be fitted with
perko closets (doors marked only).
Ground first and second floor landing to be fitted with
electrically operated smoke detectors linked back to
fuse board and together. (optical type).
Velux escape window to front installed as noted.
All steel beams to be painted with intumescent paint
giving min. 2 N r fire resistance. All steel to be
Proposed Section AA 1:50 painted with 2 coats of zinc rich primer before
erection. All structural wood to be of specified grade.
Notches and notes in structural timber to be in
accordance with BS.

Proposed Section Project : Proposed Loft Conversion Drawing no : 19_NG_PD_08


Issue :
Proposed Loft Conversion Address : 19 NUTFIELD GARDENS
Date : 05/01/21
ILFORD
A 05.01.21 DA ISSUE BL
ISSUE DATE AMENDMENT BY
IG3 9TB
Floor Joists Dormer cheek within 1m of the
150x47mm C24's @400 c/c boundary to be lined internally and
Double up Joists Direct under wall externally with 2x10mm superlx /
masterboard fire line board to
Roof Rafters provide min. of 1 hr fire resistance
150x47mm @400 c/c C24
(Double up rafters around velux Dormer clad externally with clay
windows) plain tile hanging on 25x38mm
treated s.w battens on layer of
building paper on 9mm sheating ply
Flat roof Joists
150x47mm C24's @400 c/c lining min. 75mm code 4 lead
soakers to main roof.

Beam 5 Post
No.17 152x152x37 UC 100x100x5 SHS
Boundary Line

Floor joists Beam 1


152x152x37 UC
150x47mm C24 on 450x100x20mm m/s
@400 c/c plates spreader

Roof Floor joists


Light
150x47mm C24
@400 c/c
Beam 4
Ridge Beam 203x203x46 UC
152x152x37 UC on 300x100x20mm m/s
on 3 00x100x150mm plates spreader each end
Roof deep concrete padstone
Beam 3 Light
203x203x46 UC Roof
on 500x100x30mm m/s Light
plates spreader each end

Dormer constructed with


Roof 100x100mm corner posts and
Light
120x50mm SW studs at 400mm
centres with 100mm celotex
FR5000 insulation or similar and
Beam 2
lined internally with 12.5mm vapour
152x152x37 UC check plasterboard and skim.
TA
2nos. 145x47mm C24
timbers bolted together TA
2nos. 145x47mm C24
timbers bolted together If there is no loft conversion next
doors then external brick wall to be
lined internally with 50mm celotex
FR5000 placed between 25x47
Proposed Second Floor battens @ 600crs to achieve a
U-value of 0.28W/m2k
Structural Layout Plan 1:50

Proposed Plan Project : Proposed Loft Conversion Drawing no : 19_NG_PD_09


Issue :
Proposed Loft Conversion Address : 19 NUTFIELD GARDENS
Date : 05/01/21
ILFORD
A 05.01.21 DA ISSUE BL
ISSUE DATE AMENDMENT BY
IG3 9TB
Project : 19 Nutfield Gardens IG3 9TB
Description: Structural Elements

Timber Size

Flat Roof Joists: 150x47 @ 400 Crs C16


Rafters in Enhanced Span: 2x47x150 C24
Loft Floor Joists: 150x47 @ 400 Crs
C24 Attic Floor Joists: 2B 47x150 @ 400 Crs
C24 Trimmer Floor Level 2T1 2x47x150 C24 Bolted together using M12(4.6) @ 600 Crs + Star Connectors
Trimmer Floor Level 2T2 2x47x150 C24 Bolted together using M12(4.6) @ 600 Crs + Star Connectors
Trimmer Floor Level 2T3 2x47x150 C24 Bolted together using M12(4.6) @ 600 Crs + Star Connectors
Trimmer Floor Level 3T1 3x47x150 C24 Bolted together using M12(4.6) @ 600 Crs + Star Connectors

Beam and Spreader Size

Ridge Beam RB1 152x152x37 UC Gr. 50 Spreader RB1 300x100x150mm Thick MS Plate
Floor Beam B1 152x152x37 Uc Gr. 50 Spreader for B1: 450x100x20mm Thick MS Plate Either Side Floor Beam
B2 152x152x37 UC Gr. 50 Spreader for B2: 300x100x20mm Thick MS Plate Either Side
B3 203x203x46 UC Gr. 50 Spreader for B2: 500x100x30mm Thick MS Plate Either Side
B4 203x203x46 UC Gr. 50 Spreader for B2: 300x100x20mm Thick MS Plate Either Side
B5 152x152x37 UC Gr. 50 Spreader for B2: 300x100x20mm Thick MS Plate Either Side

Structural Elements Project : Proposed Loft Conversion Drawing no : 19_NG_PD_10


Issue :
Proposed Loft Conversion Address : 19 NUTFIELD GARDENS
Date : 05/01/21
ILFORD
A 05.01.21 DA ISSUE BL
ISSUE DATE AMENDMENT BY
IG3 9TB
General Notes Project : Proposed Loft Conversion Drawing no : 19_NG_PD_11
Issue :
Proposed Loft Conversion Address : 19 NUTFIELD GARDENS
Date : 05/01/21
ILFORD
A 05.01.21 DA ISSUE BL
ISSUE DATE AMENDMENT BY
IG3 9TB
N

20 0 20 40 60 80 100

Site Plan Project : Proposed Loft Conversion Drawing no : 19_NG_PD_12


Issue :
Proposed Loft Conversion Address : 19 NUTFIELD GARDENS
Date : 05/01/21
ILFORD
A 05.01.21 DA ISSUE BL
IG3 9TB
20 0 20 40 60 80 100

Metres
N

19 NUTFIELD GARDENS
1:1250@A4
ILFORD
IG3 9TB