1 M:2020
ALL DIMENSIONS IN mm
Base Metal Thickness
(U = unlimited) Groove Preparation
Root Opening Tolerances Allowed Gas
Welding Joint Root Face As Detailed As Fit-Up Welding Shielding for
Process Designation T1 T2 Groove Angle (see 5.4.1 .1 ) (see 5.4.1 .8) Positions FCAW Notes
SMAW TC-U4b U U R = 0 to 1 /8 +1 /1 6, –0 +1 /1 6, –1 /8 All — d, e, g, j, k
GMAW TC-U4b-GF f = 0 to 1 /8 +1 /1 6, –0 Not limited
FCAW U U α = 45° +1 0°, –0° +1 0°, –5° All Not required a, d, g, j, k
R=0 ±0 +1 /4, –0
SAW TC-U4b-S U U f = 1 /4 max. +0, –1 /8 ±1 /1 6 F — d, g, j, k
α = 60° +1 0°, –0° +1 0°, –5°
Figure 5.1 (Continued)—Prequalified CJP Groove Welded Joint Details (See 5.4.1)
(Dimensions in Inches)
88