You are on page 1of 12

Version V0.

1
天津动芯科技有限公司
File No. GG-DXB51
Tianjin D-powercore Co., LTD

BMS SPECIFICATION

Product series : DXB51

Specifications DXB51-1025C-1001

Producer : 李鹏飞

Audit :

Approval :

Customer: Date:

Note: please send back this document after the product passes the test. Later

batch production will follow this document!

TEL:86-22-87895805-86 FAX:86-22-87895805-87
ADD:Building C, No 8, HaiTai East Road, XiQing District, Tianjin China
WEB:www.d-powercore.com
Version V0.1
天津动芯科技有限公司
File No. GG-DXB51
Tianjin D-powercore Co., LTD

Product features

 Satisfied  with  EN  ISO  13849‐1:2015 , EN  15194:2017 , IEC  62133:2012 ,


IEC61000‐6‐1:2016 
 Support CAN communication 
 Support Bootloader to facilitate program upgrade and maintenance. 
 Accurate  residual  capacity  estimation  (SOC),  mainly  dynamic  coulombs,  static 
open circuit voltage compensation to ensure more accurate capacity. 
 Lithium cycles statistics. 
 Record the longest time of uncharged.       
 Clock function (RTC) 
 Perfect battery protection mechanism. 
 Low power design, automatic sleep function. 
 Built‐in balance function. 
 Smart LED plate with the functions of soft‐switch and error indication.

TEL:86-22-87895805-86 FAX:86-22-87895805-87
ADD:Building C, No 8, HaiTai East Road, XiQing District, Tianjin China
WEB:www.d-powercore.com
Version V0.1
天津动芯科技有限公司
File No. GG-DXB51
Tianjin D-powercore Co., LTD

                                      CONTENT 

1、Product size and wiring ................................................................................................ 4

1.1Product size ...................................................................................................................... 4

2、 Electrical properties of products .............................................................................. 6

3、 Power and error display ............................................................................................. 8

4、 Operating instructions ................................................................................................ 9

4.1Power on and off ............................................................................................................ 9

4.2 Safety of Battery ............................................................................................................ 9

5、Change history .............................................................................................................. 11

The attachment: ............................................................................................................... 12

TEL:86-22-87895805-86 FAX:86-22-87895805-87
ADD:Building C, No 8, HaiTai East Road, XiQing District, Tianjin China
WEB:www.d-powercore.com
Version V0.1
天津动芯科技有限公司
File No. GG-DXB51
Tianjin D-powercore Co., LTD

1、Product size and wiring

1.1Product size

Figure1-1 Size of DXB51 Series(mm)

Figure1-2 Size of DXB51LED plate(mm)

Product dimension tolerance is 0.5mm.

TEL:86-22-87895805-86 FAX:86-22-87895805-87
ADD:Building C, No 8, HaiTai East Road, XiQing District, Tianjin China
WEB:www.d-powercore.com
Version V0.1
天津动芯科技有限公司
File No. GG-DXB51
Tianjin D-powercore Co., LTD

1.2Productwiringdiagram

Figure1-3 Schematic diagram of system wiring(10S)

TEL:86-22-87895805-86 FAX:86-22-87895805-87
ADD:Building C, No 8, HaiTai East Road, XiQing District, Tianjin China
WEB:www.d-powercore.com
Version V0.1
天津动芯科技有限公司
File No. GG-DXB51
Tianjin D-powercore Co., LTD

2、 Electrical properties of products

project The numerical unit

Battery pack form 10 s


Rated discharge current 25 A
Fit the type of cell The ternary lithium
Charging voltage 42 V
Charging current <10 A
The equilibrium current <70 mA
Communication current <6 mA
No communication working current <1 mA
Sleep current <50 uA
Internal resistance 5.0 mΩ
Single section voltage error <20 mv
Total voltage error <0.1 v
precision The current error <3 %
The temperature error <2 ℃
Accuracy of SOC 5 %

Communication mode V-in Response latency Note

CAN-bus +5V <50mS(3mS) Can network,


+5V/CAN_L/CAN_H/GND

Item Value Unit Recovery

Overvoltage protection 4250 mv Automatic


voltage recovery of
Overvoltage recovery 4215 mv voltage drop
voltage delay
Voltage Overvoltage protection 4 S
delay
protection Overvoltage recovery delay 200 mS
Undervoltage protection 2800 mV Automatic
voltage recovery of
Undervoltage recovery 3000 mv voltage
voltage recovery delay

TEL:86-22-87895805-86 FAX:86-22-87895805-87
ADD:Building C, No 8, HaiTai East Road, XiQing District, Tianjin China
WEB:www.d-powercore.com
Version V0.1
天津动芯科技有限公司
File No. GG-DXB51
Tianjin D-powercore Co., LTD

Undervoltage protection 4 S
delay
Undervoltage recovery 200 mS
delay
Balance voltage 3900 mv
Discharge over current 1 30 A Self-recovery。
protection
Discharge-overcurrent 1 S
protection delay
Discharge over current 2 80 A Self-recovery.
protection
Discharge overcurrent 2 80 mS
Current delay
Charge overcurrent 20 A Remove
protection protection charger after
Charge overcurrent 40 mS 500mS
protection delay
Charge overcurrent 10 S
self-recovery delay
Short circuit protection 200 A Remove the
Short circuit protection 200 uS load
delay
Discharge high temperature 65 ℃ Automatic
protection delay recovery
Discharge high temperature 60 ℃
recovery
Discharge high temperature 2 S
protection delay
Temperatu
Discharge high temperature 1 S
recovery delay
re
Charging high temperature 55 ℃ Automatic
protection delay recovery
protection
Charging high temperature 50 ℃
recovery
Charging high temperature 2 S
protection delay
Charging high temperature 1 S
recovery delay

TEL:86-22-87895805-86 FAX:86-22-87895805-87
ADD:Building C, No 8, HaiTai East Road, XiQing District, Tianjin China
WEB:www.d-powercore.com
Version V0.1
天津动芯科技有限公司
File No. GG-DXB51
Tianjin D-powercore Co., LTD

Charging low temperature 0 ℃ Automatic


protection delay recovery
Charging low temperature 5 ℃
recovery
Charging low temperature 2 S
protection delay
Low temperature charging 1 S
recovery delay

3、 Power and error display

Red light flashes: the capacity is 0%-9%


The red light is on: the capacity is 10%-19%
The first green light is on: the capacity is 20%-39%
The first green light flashes: charging and the capacity is
0%-39%
First two green lights are on: the capacity is 40%-59%

The first green light is on and the second green light flashes:

charging and the capacity is 40%-59%


First three green lights are on: the capacity is 60%-79%
First two green lights are on and third green light flashes:
charging and the capacity is 60%-79%

All the green lights are on:the capacity is 80%-100%

First three green lights are on and the fourth green light
flashes: charging and the capacity is 80%-99%
The red light and the fourth green light are on: high
temperature protection
The red light and the third green light are on: low temperature
protection
The red light and the second green light are on: over-current
protection

TEL:86-22-87895805-86 FAX:86-22-87895805-87
ADD:Building C, No 8, HaiTai East Road, XiQing District, Tianjin China
WEB:www.d-powercore.com
Version V0.1
天津动芯科技有限公司
File No. GG-DXB51
Tianjin D-powercore Co., LTD

4、 Operating instructions

4.1Power on and off

Boot mode Shutdown mode

Item Describe Item Describe

Button There is a switch button on the Button Long press the button 3S on the
battery display board. When the power display panel when the
battery is off, press the button to battery is turned off
turn it on.
Charging In the case of shutdown, connect Auto sleep When the battery current is
to the charger after automatically persistently less than 200mA
starting (configurable), no
communication, the battery
shutdown after 30 minutes
(configurable, need to cooperate
with button wake-up)
Communi In the case of shutdown, LIN bus Under Auto sleep
cations or UART communication will wake voltage
up the battery to boot protection

4.2 Safety of Battery

 BMS installation should pay attention to electrostatic protection.

 Make sure the battery series is consistent with BMS before BMS installation.

 During the installation process, the total negative electrode of the battery

should be connected first, and the PACK wire should be connected to the

battery and confirm the correct sequence before plugging in the BMS.

TEL:86-22-87895805-86 FAX:86-22-87895805-87
ADD:Building C, No 8, HaiTai East Road, XiQing District, Tianjin China
WEB:www.d-powercore.com
Version V0.1
天津动芯科技有限公司
File No. GG-DXB51
Tianjin D-powercore Co., LTD

 After the completion of battery installation, it shall be communicated firstly to

confirm the correct battery assembly before charging and discharging, and a

full charge and a full discharge shall be guaranteed.

 In order to ensure the stability of the system, the key indicator light between

the small board and the main board of the wire should not be greater than

50cm.

 Please do not modify the configuration of BMS parameters by yourself. Please

contact the manufacturer if necessary.

 All protection parameters should be configured strictly according to the actual

conditions of the battery, or it may cause danger. Please pay attention to the

following:

1、If short circuit current setting is too large, because of the battery capacity

is small, discharge rate is small, the battery internal resistance is large and

other reasons, even if the positive and negative poles of the complete short

circuit cannot reach the short circuit protection current, resulting in battery

damage。

2、If overvoltage protection parameters are too high, the battery will cause

unrecoverable damage due to overpressure, serious will lead to battery

damage。

TEL:86-22-87895805-86 FAX:86-22-87895805-87
ADD:Building C, No 8, HaiTai East Road, XiQing District, Tianjin China
WEB:www.d-powercore.com
Version V0.1
天津动芯科技有限公司
File No. GG-DXB51
Tianjin D-powercore Co., LTD

3、If under voltage protection parameters are too low, the battery due to

over discharge lead to irreversible damage。

4、If the configuration parameter exceeds the limit parameter of protective

plate, BMS and battery will be damaged。

5、Change history

date version describe Hardware  Software


version version
2019.09.09 V0.1 Specification V0.2 V0.14
preparation

TEL:86-22-87895805-86 FAX:86-22-87895805-87
ADD:Building C, No 8, HaiTai East Road, XiQing District, Tianjin China
WEB:www.d-powercore.com
Version V0.1
天津动芯科技有限公司
File No. GG-DXB51
Tianjin D-powercore Co., LTD

The attachment:

Packing pictures:

TEL:86-22-87895805-86 FAX:86-22-87895805-87
ADD:Building C, No 8, HaiTai East Road, XiQing District, Tianjin China
WEB:www.d-powercore.com

You might also like