You are on page 1of 95

KA022 Series

Automatic revolving door


Installation Manual
CONTENT
INTRODUCTION .................................................................................................................................................. 3

1. THE BASIC STRUCTURE OF THE DOOR ................................................................................................ 4

2. THE REQUIREMENTS FOR INSTALLATION............................................................................................ 4

3. THE INSTALLATION OF THE GROUND RAIL.......................................................................................... 6

4. ASSEMBLY THE SIDEWALL SEGMENTS. ............................................................................................. 10

5. THE ASSEMBLY OF SIDEWALL SEGMENTS ........................................................................................ 13

6. THE INSTALLATION OF CANOPY RING................................................................................................. 15

7. THE INSTALLATION OF “Z”- SHAPE SUPPORTING RACK .............................................................. 18

8. THE INSTALLATION OF “C”- SHAPE RAIL ........................................................................................... 19

9. THE INSTALLATION OF HANGING SPOKES ........................................................................................ 22

10. THE INSTALLATION OF THE MAIN BEAM........................................................................................... 23

11. THE INSTALLATION OF THE SPOKES ................................................................................................. 26

12. THE ADJUSTMENT OF CIRCLE ............................................................................................................. 27

13. THE INSTALLATION OF SEALED NYLON SHORT BRUSH ............................................................. 28

14. THE INSTALLATION OF CEILING SUPPORT RING ........................................................................... 28

15. THE ASSEMBLY OF REVOLVING-WING SEGMENTS ....................................................................... 30

16. THE INSTALLATION OF THE REVOLVING WING .............................................................................. 36

17. THE INSTALLATION OF THE SHOWCASE .......................................................................................... 37

18. THE INSTALLATION OF THE SHOWING DOOR ................................................................................. 39

19. THE INSTALLATION OF SLIDING DOOR ............................................................................................. 43

20. THE INSTALLATION OF ELECTRIC CONTROL SYSTEM................................................................. 47

21. THE INSTALLATION OF ELECTRO-MECHANICAL LOCK. .............................................................. 51

22. THE INSTALLATION OF GLASS............................................................................................................. 54

23. THE INSTALLATION OF SAFETY RUBBER IN THE OPENING ....................................................... 55

24. THE INSTALLATION OF TOP RING ....................................................................................................... 55

25. THE INSTALLATION OF THE CEILING ................................................................................................. 57

26. THE INSTALLATION OF THE BOTTOM BOARD OF THE SHOWCASE......................................... 60

27. THE INSTALLATION OF SLIDING DOOR’S RADAR AND DECORATIVE LIGHTS ...................... 60

28. DEBUGGING ILLUSTRATION ................................................................................................................. 61

1
29. THE INSTALLATION OF DECORATIVE PLATE ................................................................................... 83

30. THE INSTALLATION OF ANTI-DUST PLATE ....................................................................................... 85

31. FINAL-STAGE MAINTENANCE ............................................................................................................... 86

32. MALFUNCTION DISPOSAL ..................................................................................................................... 86

ATTACHED FORM 1: FLOOR HORIZON MEASURING RESULT ........................................................... 87

ATTACHED FORM 2: ENTRANCE MEASURING VALUE ......................................................................... 88

ATTACHED FORM 3: GROUND TRACK HORIZON MEASURING VALUE ........................................... 88

FIGURE ONE...................................................................................................................................................... 89

FIGURE TWO ..................................................................................................................................................... 90

DISPLAY 1: MAIN TOOLS FOR INSTALLATION PROCESS ................................................................... 91

2
Introduction
KBB Automated Entrances Inc. is the biggest specialized company dealing with automatic door
design, production, sales and after sales service nationally. Located in Beijing Changping
high-tech industrial park, with a production base of over 50000 square meters. KBB uses exquisite
specialized technology, advanced management methods and specialized workers hand in hand to
create first class automatic doors.

KBB Automated Entrances Inc. abbreviated as “KBB Corporation” and further abbreviated to
“KBB" and "KBB Automatic Door" are all legal names and symbols. KBB is legally acknowledged
in accordance with laws stipulating legal liability of un-permitted use of company trademarks.

The information in this manual has been compiled in accordance with the Peoples Republic of
China's information regulations. This manual includes information from cut-off to time of print. KBB
Corporation is fully responsible for the revisions and explanations of this manual. KBB reserves
the right to change products after the print date of the manual without notification. Pictures,
schematic diagrams and effect charts are in place for reference only. in comparison of a diagram
and the object, the object shall be taken as standard.

The copyright for this manual is owned by KBB Automated Entrances Inc.
Copyright protected.

3
1. The basic structure of the door

The basic structure of KA022-2*4 series as shown in Figure 1-1

图 1-1

2. The requirements for installation

2.1
Ground
2.1.1
The requirements of ground
Finished floor with hard and smooth surface is required and the thickness of the floor must be greater than
150mm

The Max. flatness tolerance shall not be more than±3mm.

2.1.2
Measure ground
Confirm the central point according to installation requirement. Draw a circle regarding R as radius, the
radius of this circle is the same as the ground rail outer curve, please refer to the figure 2-1. Mark 21 points
on the ground as shown in figure 2-1, No.11 is central point.

4
Table 2-1 R data ㎜

KA022-2364 KA022-2424 KA022-2484


R 1834 2134 2434

Figure 2-1
Place the gradienter on the position (indoor or outdoor),5-7 m far from the center point of revolving door.
First , measure the height of point 11, regard its height as the standard , then measure the height of other 20
points, and fill the measure data in the Table 1 (to file this table with installation and maintenance parts).
According to the ground requirements, check the ground.

2.2
Opening dimension
2.2.1
The requirements of opening dimension

Refer to Figure 2-2,the deflection requirements of opening dimension:Width deflection is+5~+15mm,

Height deflection is +5~+10mm,Verticality error at one side is 0~5mm,that is:B1≥D+5,B2≤D+15,

H1≥H+5,H2≤H+10,T≤5。

According to the products specification and the deflection requirements, opening dimension should accord
with table 2-2.

Figure 2-2

H 5
H1

Max DT of the door(D)


Table 2—2 The data sheet for measuring opening dimensions (mm)

Products Model KA022-2364 KA022-2424 KA022-2484


Max. DT of the door 3688 4288 4888

body(D)

Total height of the door 2540 2540 2540


body (H)
Min. clear width B1 of
≥3693 ≥4293 ≥4893
opening (B1)
Max. clear width B2 of
≤3703 ≤4303 ≤4903
opening (B2)
Min. clear height H1 of
≥2545 ≥2545 ≥2545
opening (H1)
Max. clear height H2
≤2550 ≤2550 ≤2550
of opening (H2)
Verticality error at one
≤5 ≤5 ≤5
side (T)

Notice:Above data accord with the revolving door of surface anodizing treatment,If need to be decorated,

please add double thickness of metal board on the dimension of width direction.
2.2.2
Measure the dimension of opening

Measure the opening dimension with Steel Tape-measure,and fill the data in the table2.

According to 2.2.1 the requirements of opening dimension,check the opening dimension.

Please go to the next step after the above items are qualified.

3. The installation of the ground rail.

3.1

Draw a beeline which is vertical with the door opening direction through the center point,the beeline

intersects with the (radius R) circle at A.B (Figure 3-1)

6
Figure 3-1

3.2

Measure with Steel Tape-measure,Find out one center point on each outer curve of the ground rail.

And make mark lines.

3.3

Place the ground rail,and put the mark lines that you made at the symmetry center exactly at the points A

and B, and the outer round of ground rail must be symmetrical with the finished round on the ground.

Figure 3-2

Figure 3-3 is layout of the B point.

7
Figure 3-3

3.4

Check the opening width, the deflection should be ≤3 ㎜.

3.5

Drill twelve holes which depth is about 170mm by using an aiguilles of ¢15 according to the holes of two

pieces of ground rails on the ground.. Clean earth in the holes after drilling , clean floor and insert plastic
pipe of floor fixed screws into the these holes , and put the ground rail on the original place, then insert

twelve pieces of floor fixed screws(ST7×160)into two pieces of ground rail.(Figure 3-4)。

8
Figure 3-4

3.6
Place the gradienter on the position (indoor or outdoor), 5-7 m far from the center point, measure the
flatness of ground rails, to measure 5 points of each piece, then mark 10 points number as the Figure 3-5
shows.

Figure 3-5

3.7
Adjust the flatness of the ground rail by using spacers; the tolerance must be less than 1mm.

Figure3-6

9
3.8
After fixing the twelve pieces of screws, please measure the flatness of the ground rails again and make

sure that the tolerance is ≤ 1mm. And please fill the data in the table 3. (File this table in the maintenance

part)

4. Assembly the sidewall segments.

If the assembly of sidewall segments has finished before leaving factory, please skip this part.

4.1
The sidewall segments have 4 pieces. The product has been pre-assembly before leaving factory, every
piece of segments is the “semi-manufactured goods “, every spare part couldn’t be mixed. Therefore, the
same spare part will have the same group number, the group number of sidewall segments is 1----4 group,
that is: all the spare parts with the same number “1” are used to assembly the sidewall segments of the first
group.
The position of the group number is: in the glass groove close to the ends of the upper and lower curve
frame, in the glass groove close to the lower end of the left mullion and the right mullion and the central
mullion. (Attention: The central mullion couldn’t be assembled upside down).
Find out the spare parts with the same group number, and place them group by group.

4.2
There should be the protection layer to prevent scathe on the process of assembly.

4.3

Insert the central mullion into the mid-groove of the upper curve frame, adjust the assembly gaps≤0.3 mm,

the radial deflection of upper curve frame and central mullion≤0.3 mm, then fix the central mullion and

upper curve frame with two pieces of inner hexagon self-tapping screw with anaerobic glue.(Figure 4-1)

10
Upper curve frame

Central mullion

Figure 4-1

Upper curve frame

Central mullion

Lower curve frame

Figure 4-2

4.4

Connect the lower curve frame to central mullion with the same way.(Figure 4-2)。

4.5
Insert the left and right mullion of sidewall segments into the groove of the upper and lower curve frame,

11
adjust the assembly gaps≤0.3 mm, the radial error of curved frame and mullion≤0.3 mm, then fix all the

curve frame and the mullion with ST6.3×38 inner hexagon self-tapping screw. Figure 4-4 shows the

finished sidewall segments.

Figure 4-3

Upper curve frame

Central mullion

Right mullion
Left mullion

Lower curve frame

Figure 4-4

4.6

Check:Check the diagonal dimension of sidewall segments with tape-measure, the tolerance≤2 mm; check

12
the assembly gaps with stopple ruler, the assembly gap≤0.3 mm, check the radial error of the curve frame

and mullion, the radial error≤0.3 mm .

4.7 Repeat the steps 4.1~4.6,install the other three segments.

5. The assembly of sidewall segments

5.1
Place sidewall segments of the same side on the ground rail, please keep more than 200mm distance in the
middle.
Attention: The mullion with a few operation buttons should be placed indoor, the position can't be
exchanged.

5.2
Install the rubber strip. Insert the two connection surfaces of sidewall segments with dual tape and rubber

strip. (Figure 5-1)。

Figure 5-1

5.3
Insert and fix the two sidewall segments with 3 or 4 pieces of inner hexagon self-tapping screw (model of

ceiling height 2300mm has 4 pieces) , and ensure the joint gap≤0.3mm, radial error≤0.3mm, adjust the

central gap to overlap with the midline of revolving door, deflection ±1mm(Figure 5-2)。

13
Figure 5-2

5.4

Repeat steps 5.1~5.3.Install the other side sidewall segment(Figure 5-3)。Measure and adjust the

opening dimension L of sidewall.

Requirements: the upper and lower opening dimension difference in the same side≤3mm, the same height

opening dimension difference on the both sides ≤3mm

Figure 5-3

14
Lower curved frame

Ground rail

Figure 5-4

5.5

Fixing the sidewall segments into the ground rail with 8 pieces of ST5.5×12 inner hexagon self-tapping

screw(Figure 5-4)。

6. The installation of canopy ring

6.1
Place the two canopy rings (without Radar holes) on the two sidewall frames, To fix the ends of canopy
ring on the sidewall frame with 4 sets of inner hexagon self-tapping screws and 8x24 thickness spacers
( thickness 5mm).(Figure 6-1).
Figure 6-2 is layout of position I.

15
Figure 6-1

Figure 6-2

6.2


Install the other two canopy rings with the same way.(Figure 6-3)

16
Figure 6-3

6.3

Measure the distance between the edge of the canopy ring and the outer curve of sidewall segments with

Depth—measure Ruler, measure 6 points on the circle, adjust the canopy ring, and the data is : surface

paint or anodized 4±0.5mm、cladding 5~6 mm ( Figure 6 ). Measuring with stopple ruler, adjust the

assembly gap of canopy ring ≤0.3 mm.

RALcoating or anodized 4+0.5mm

Figure 6-4

17
7. The installation of “Z”- shape supporting rack

To fix 10 pieces of “Z”- shape supporting racks on the canopy ring, (located on the top of 10 mullions of
the sidewall frame separately). Refer to figure 7-1. To fix 4 pieces of “Z”- shape supporting racks on the
sidewall, located on the top of middle mullions of the sidewall with 2 sets of ST6.3 x 38 inner hexagon
screws and 8 x 24 (thickness 5mm) spacers for each piece. The rest 6 pieces fixed with 2 sets of M8 x 40
inner hexagon screws and 8 x 16 (thickness 1mm) spacers for each piece. Figure 7-2 is the enlarged
drawing of “Z”- shape supporting racks ins

Figure 7-1

Figure 7-2

18
8. The installation of “C”- shape rail

8.1
The installation of long “C”- shape rail. Total are four pieces, two long, two short. Before leaves the factory,
2 brackets has installed on every long “C”- shape rail. And place these two long ones on the installation

location. (figure 8-1), each bracket fixed on the “Z”- shape supporting racks with 2 sets of M8×40 inner

hexagon screws, 8×24 (thickness 5mm) spacers ,nuts, 8×24 (thickness 1mm) spacers and spring spacers.

Please tighten screws properly to ensure the brackets slid on the “Z”- shape supporting racks.

Figure 8—1

8.2
Please install two brackets separately on the middle of two short “C”- shape rails (figure 8-2), each bracket

is fixed on the “C”- shape rail with 8 sets of M8x 25 inner hexagon screws and 8×16 (thickness 1mm)

spacers Please tighten the screws of “C”- shape rails’ undersurface firmly first, to make sure it’s no gap
between “C”- shape rails’ undersurface and the bracket, then tighten the screws of “C”- shape rails’ upper
surface firmly.
Notice: Upward the face marked “UP " of “C”- shape rail, do not put upside down.

19
Figure 8-2

8.3
To place these two short “C”- shape rails on the installation location. (Figure 8-3). Please fix the bracket on the
“Z”- shape supporting rack. with the same way.

Figure 8-3

8.4
To connect the long “C”- shape rail and short one with the rest 4 brackets ( Figure 8-4), each bracket is

fixed on “C”- shape rail with 16 sets of M8×25 inner hexagon screws, 8×16 (thickness 1mm) spacers, do

not tighten them firmly first. To adjust both sides of “C”- shape rails’ joint,and to make sure the level

flatness tolerance≤0.3mm. To measure with the stopple ruler, and to adjust the gap:1.5~2mm(Figure

20
8-5). Please tighten the screws which located on the side of “C”- shape rails’ undersurface firmly first, to

make sure it’s no gap between “C”- shape rails’ undersurface and the bracket, then tighten the screws of
“C”- shape rails’ upper surface firmly. At last to fixed four brackets on the “Z”- shape supporting brackets

with 8 sets of M8×40 inner hexagon screws, 8×24 (thickness 5mm) spacers ,nuts, 8×24 (thickness 1mm)

spacers and spring spacers. Please tighten screws properly to ensure the brackets slid on the “Z”- shape
supporting rack.

Figure 8-4

21
Figure 8-5

8.5
To adjust “C”- shape rail to be concentric with canopy ring. Measure 10 points along the circle. To adjust
the gap on the measure points between “C”- shape rail and canopy ring is 45mm utilizing oval-shaped holes

of “Z”- shape supporting racks and bracket by removing “C”- shape rails(Figure8-6),to ensure it to be

concentric with canopy ring. After adjustment, tighten connected screws of brackets and “Z”- shape
supporting rack.

Working face

Figure 8-6

8.6
To adjust the working face flatness of “C”- shape rails (see figure8-6). Please place the gradienter on the
position ,5~7 meters far from the central of the door, measure the height value of “C”- shape rail’s working
face located on these 10 brackets. Increase/ decrease spacers of “Z”- shape supporting rack. to ensure the
height deflection of these 10 points is less than 1mm.

9. The installation of hanging spokes

Please fix two pieces of hanging spokes on the top of door entrance‘s bracket with 4 sets of M8x30 inner

hexagon screws, nuts, spacers and spring spacers.(Figure 9-1)。

22
Figure 9-1

10. The installation of the main beam

10.1
Please check if the composing parts of the beam are completed according to the following figure.

① main beam 1 piece ② brake unit assembly 2 pieces ( including wheels)

③ drive unit assembly 2 pieces ( including one reducer, one motor, two belt wheels, one belt, one

wheel) (Figure 10-1)

Drive unit assembly Brake unit assembly

Figure 10-1

23
10.2
To check the flexibility of each wheel. Drive unit and brake unit should push back to the retractile position
along the arrow direction.(Figure 10-2). To loosen properly 8 pieces of M12x35 screws to ensure the fixed
board to slid on the main beam.

Figure 10-2

10.3
To take down the 8 pieces of M12 x 3 screws which are fixed on the connected board beforehand for later

use(Figure 10-3)。

Figure 10-3

10.4
Please remove the main beam assembly from the door opening into the installed sidewall segments.

10.5
Please hang the hoisting pothook of hoist tackle on the hanging spokes.

10.6

Please hang the sling hook on the bottom of the main beam.(Figure 10-4)。

24
Notice:Please tie the hook on the bottom of the main beam reliably. Do not appear safety problem.

Figure 10-4

10.7
Please hang the beam with hoist tackle, and push the driver and brake to the rail direction along the arrow
shows, the wheels put inside of “C”- shape rail’s face, and make the directional screw on the fixed board to
fit with the screw eye on the main beam. And install 8 pieces of M12 x 35 bolts that just took down, and

then tighten the directional screws.(Figure 10-5)

25
Figure 10-5

10.8
To loosen hoist tackle, let the beam down, to observe whether the 4 wheels are jointed with the rail
completely, if any wheel doesn’t, we should tighten up the other wheels, then loosen the fixed screw of this
wheel. To adjust the wheel to joint with the “C”- shape rail by the gap between screw and screw eye.
Meanwhile adjust each wheel to make its axes cross the beam center. Tighten it firmly after adjustment.

Figure 10-6

11. The installation of the spokes

To connect the bearing base and bracket with 6 pieces of the spokes, one end of every spoke is fixed on the

bracket with 1 set of M8 x 30 inner hexagon screw, two pieces of flat spacers, spring spacer and nut,

another end is connected to the bearing base with 1 set of M8 x 50 inner hexagon screw (adjustment screw),

spacer and two pieces of nuts.(Figure 11-1). Figure 11-2 is the layout figure of the six spokes. While

installation, do not tighten the spoke’s locked screw on the bearing base firmly.

26
Figure 11-1

Figure 11-2

12. The adjustment of circle

There are four connection boards on the end of the main beam, to mark one point on the undersurface of
any connection board. Push the main beam to rotate, measure the distance from the marked counterpoints
of the six spokes to canopy ring, then make the comparison between the measured values of each point. If

the difference between Max. and Min <2mm, please tighten the adjustment locked nut on the bearing base

( Refer Figure 11-1);If the difference>2mm,please tighten the bolt of Max. Value, loosen the bolt of

Min. value until the difference<2mm, then tight the nut. Repeat the steps above. Please tighten all the

27
locked nuts if confirm the difference<2mm.

Please push the main beam to make trial –rotation, require for flexibility and noiseless.

13. The installation of sealed nylon short brush

The whole circle is filled with sealed nylon short brush of canopy ring. Please plug the brush into the gap of

canopy ring.(Figure 13-1).

Figure 13-1

14. The installation of ceiling support ring

14.1
Totally is four pieces, two are with oblong hole. Please fix these two on the bottom of main beam
connection board with 6 sets of M8x25 inner hexagon screws, spacer and spring spacer, (Figure 14-1). Do
not tighten the screws firmly first.

28
Figure 14-1

14.2

Please fix 6 accessorial wheels, 6 spacers on another two ceiling support ring with M8×25 screws, spacer

and spring spacer separately .(Figure 14-2)。

Figure 14-2

14.3
Please install the two above ceiling support ring. Connect to the two pre-installed ceiling support ring

through connection board of accessorial wheels. The gap between them should be≤0.3mm.

14.4
Measure 10 points along the circle, and adjust the radial gap between ceiling support ring and canopy ring

11±2mm. To adjust the radial gap by using one black plastic spacer ( thickness 3mm)、one yellow plastic

spacer ( thickness 4mm)and one red plastic spacer ( thickness 2mm)to fill into it. To adjust undersurface of
ceiling support ring and canopy ring to a same level by increasing/ decreasing spacers between

accessorial wheels’ connection board and ceiling support ring,(Figure 14-3).Tighten all screws firmly

after adjustment.

29
Figure 14-3

15. The assembly of revolving-wing segments

The revolving-wing totally have two segments with the same construction. If the assembly has finished
before leaving the factory, please skip part. The installation process of one piece is described below:

15.1
Same as the sidewall segments, the assembly of the revolving-wing has finished before leaving the factory,
group numbers are 5 and 6 , the mark position of group number is as the same as the sidewall segments.

Also, assembly gap≤0.3mm,radial error≤0.3mm.

Find out the spare parts of same group number, place them by groups.

15.2
To fix upper/ lower curved frame and middle mullion of the revolving-wing together with 8 pieces of ST6.3

×38 inner hexagon screws.(Figure 15-1)。

Notice: two middle mullions are different, one is with 4 small holes (for the installation of lock frame),
another one is without hole, and the position can’t be exchanged. Also, the four holes should be

located on one side of the mullion’s middle line.(Figure 15-2 is the magnifying drawing of A)。

30
Figure 15—1

Figure 15-2

15.3

To fix the front mullion of the revolving-wing on the upper/ lower curved frame with 4 pieces of ST6.3×38

inner hexagon screws(Figure 15-3)。

31
Figure 15—3

15.4
The installation of the revolving wings’ back mullion. Please firstly lead 3 wires through the gap of the
revolving wings’ back mullion and lower curved frame out of the three holes separately ,These 3 wires are
the connection for safety beam, and then fix the back mullion of the revolving wings on the upper/ lower

curved frame with 4 pieces of ST6.3×38 inner hexagon screws. Figure 15-4 shows the condition after

installation completion.

Figure 15-4

32
15.5

Check the diagonal of the revolving-wing ≤2mm,connection gap≤0.3mm,radial error≤0.3mm.

15.6
The installation of locked frame. To fix locked frame on the middle mullion with 4 holes of the revolving


wings with 4 pieces of ST5.5×12 self-tapping screws(Figure 15-5)

Figure 15-5

15.7
The installation of the revolving wings’ connection sheet. To fix it on the back mullion of the revolving

wings with 3 sets of M6×20 inner hexagon screws, flat spacer and spring spacer.(Figure 15-6)

33
Figure 15-6

15.8
The installation of lower brush. To bend the lower brush (width 50mm) of revolving wing to arc refer to the

revolving wing’s radian. To fix it on the lower curved frame with 7 pieces of ST5.5×22 inner hexagon

screw and 7 thick spacers ( Figure 15-7).

Notice: Lower brush (width 50mm) of revolving wing is installed close to the revolving wing’ outer
arc.

Figure 15-7

34
15.9
The installation of revolving wing’s front brush. Please plug a piece of brush (width 63mm) into the groove

of revolving wing’s front mullion.(Figure 15-8)。

Figure 15-8

15.10
The installation of revolving wing’s back brush. Please plug a piece of brush (width 63mm) into the groove
of revolving wing’s pinch plate, plug corner brush into the bottom of groove, and fasten the pinch plate

with the back mullion of revolving wing.(Figure 15-9). When install the pinch plate, it should install one

side first, then beat lightly another side with rubber hammer.

35
Figure 15-9

16. The installation of the revolving wing

16.1
To fix the revolving wing on the main beam connection board and an accessorial wheel connection board

with 7 sets of M8×80 inner hexagon screws, 8×24 ( thickness 5mm) spacers and spring spacers. Please

tighten the screws properly. To tighten the bolt of revolving wing on the connection sheet(the position of
connection sheet see figure15-6). To fix the bolt of revolving wing on the accessorial wheel connection

board with one set of M8 nuts(2 pieces), flat spacer and spring spacer(Figure 16-1). Do not tighten the

nut first. To adjust the distance between revolving wing and sidewall segment about 50mm±2mm by the
long hole of connection board, and then tighten all the bolts and nuts firmly.

Figure 16-1

16.2
The installation of the safety switch of revolving wing. Refer to Figure16-2, to install one side of the safety
switch first, and then beat the other side lightly by rubber hummer. After the installation completed, check
the tightness of safety switch, if any looseness is found, remove the safety switch, and maintain the bayonet.
Choose 4 points along the direction of length, maintain the bayonet to the outer side with plier, and then
reinstall the safety switch.

Notice: The “NO Knocking” signs will be sticking on the two ends of the safety switch. Please read

carefully, and install the safety switch according to the requirements. Take off the signs when the
installation is finished.

36
Figure 16-2

16.3

To check the distance between the lower curved frame and ground. 28mm±3mm

16.4
To repeat steps 16.1-16.3, install the other revolving wing.

17. The installation of the showcase

There are two sets of showcase, showing door and sliding evacuation door, the structure and the installation
process for both sets are completed the same. The installation process of one piece is described below:

17.1
The installation of brush. Put one end of the brush (width: 50mm) into the groove of brush, and pull until
the other end in the same line with the groove of brush. (Figure 17-1)
Notice: Brush is installed on the side which closes to the outer side of showcase.

Showcase outer side

Brush groove

Lower frame of showcase

Brush

37
Figure 17-1

17.2
To remove the pinch plate that installed on the showcase before leaving the factory (Figure 17-2). Method:
knock one side lightly with rubber hummer.

Figure 17-2

17.3

To hang the showcase to the connection board under the main beam with 2 sets of inner hexagon screws, 8

×24 (thickness 5mm) spacers and spring spacers.

Figure 17-3

17.4
To connect the lower frame of showcase and the lower curved frame of revolving wing with the connection
board of showcase and revolving wing, and fix showcase connection sheet on the lower frame with 2 sets
of M8×22 inner hexagon screws and spacers. The installation method refers to Figure 17-4.

38
Figure 17-4

18. The installation of the showing door

18.1
The installation of the brush. To fix the brush (Width: 50mm) on the buckle of the brush of the showing

door with 6 pieces of ST5.5×12 inner hexagon self-tapping screws and 6 brush thick spacers of swing

door.(Figure 18-1)

Thick spacers of swing door

brush

Figure 18-1
Notice: The brush should be installed on the side which closes to the outer side of showing door.

18.2
To fix the showing door on the showcase through the upper / lower connection pedestal of showing door

with 4 pieces of M6×20 inner hexagon screws. (Figure 18-2)

39
Figure 18-2

18.3
To install 2 showcase connection sheet and 1 revolving wing connection sheet on the showcase or curved

sidewall with 4 sets of M8×22 inner hexagon screws and spacers. Refer to Figure 18-3.

Figure 18-3

18.4
To install the ground frame of showing door. Refer to Figure 18-4, to fix ground frame units with 2 sets of

M8×25 inner hexagon screws, nuts and spacers.

40
Figure 18-4

18.5

To fix showcase triangle frame to showcase with 5 pieces of ST5.5×12 inner hexagon screws. (Figure

18-5)

Figure 18-5

41
18.6
To fix two sets of showcase locks on the lock frame. (If is already installed before leaving the factory, skip
this part)

Figure 18-6

18.7
To adjust the gap of showing door
To close the showing door and insert the leading cone into the hole, observe whether the door gap is even.
Please adjust the position of installing screw and leading cone of the ground frame to make door gap even,
about 4mm width. The lock of showing door can be easily operated. (Figure 18-7)

Figure18-7

42
19. The installation of sliding door

19.1
The installation of brush

To fix 2 pieces of brushes (width 50mm) into the buckle of brush with 8 pieces of ST5.5×12 inner hexagon

self-topping screws and 8 brush thick spacers of swing door .(The method is similar as the showing door’s
brush installation).
Notice: For the two sliding doors, the brush is installed in different sides to make the brush in the
same line after the installation of the sliding door.

19.2
To remove the pinch plate. (Figure 17-2).

19.3
Screw out 3 pieces of M8 screws to remove central-axis cover of the sliding door. (Figure 19-1)

Figure 19-1

19.4
To check the tightness of toothed belt, if find any looseness, release the fixed screws of the stretching pulley.
Move the stretching pulley to the outer side to make the proper tightness of toothed belt, and then tighten
the screws firmly.

19.5

To connect the pulley and sliding door body with 4 sets of M8×30 hexagon screws and spacers. To adjust

the gap between door body and showcase to be 10mm.Tighten the bolts firmly. To re-install the central-axis
cover that was just removed (Figure 19-2)

43
Pulley

Sliding door body

Showcase

Figure 19-2

19.6
To release 2 pieces of hexagon bolts and locked nut of adjusting screw. Please adjust the screws to ensure
the gap between sliding door body and the ground to be 36mm. Then twist the bolts and nuts. (Figure
19-3).

Locked nuts

Adjusted screw
Hexagon screw

Figure 19-3

19.7
To insert the bearing of the sliding door’s stop piece into brush groove from one end of showcase and fix it

on the thick spacer of the sliding door’s stop piece with 2 pieces of M5×10 inner hexagon screws.(Figure

44
19-4) To adjust the position of stop piece by adding/decreasing flat spacers between stop piece and the
thick spacers; To adjust the angle of stop piece according to the arrow direction to adjust the gap between
stop piece and sliding groove by the gap between screw and screw hole.

Thick spacers

Showcase brush groove

Stop piece bearing

Figure 19-4

19.8
To install the other door leaf with the same steps above.

19.9
To adjust the sliding door. Refer to Figure 19-5 and Table 19-1, adjust sliding door by following steps.
When the door is closed, the gap between the both sliding door body is 6 mm.

45
Figure 19-5

Table 19-1 Reference data of sliding door adjustment

Specifications L1 L2(close width of sliding door) L3(open width of sliding door)

KA022-2364 2008 2144 ≥3240

KA022-2424 2308 2444 ≥3840

KA022-2484 2610 2744 ≥4440

19.9.1
Please close the sliding leaves, to aim the door gap at the revolving center.
19.9.2
Please move inner-side moving stopper to make it closed to pulley units, and twist the inner hexagon
screws of moving stopper.
19.9.3
To push the sliding leaves to the opening width to ensure the equal sliding distance of both leaves.
19.9.4
To move outer-side moving stopper to make it closed to pulley units, and tighten the inner hexagon screws
of moving stopper firmly.

46
20. The installation of electric control system

20.1
The installation of main control box.
20.1.1

To fix connection board of main control box to the upper surface of “C shape” rail with M8×35 inner

hexagon screws, and the distance between connection board and the side of outer arc will be 15-50mm.
(Figure 20-1)

Figure 20-1
20.1.2

To hang the main control box to the connection board with M8×22 inner hexagon screws.

20.1.3
To connect input power wire of main control box to power box , and to connect output power wire to slip
ring.

Notice: To ensure good connection between ground wire of main control box and door body.

20.2
The installation of power box
To fix power box to the side of outer arc of “C shape” rail with M4 inner hexagon screws (Figure 20-2).

According to the sign, connect the standard power (AC220V±10%) to the connecting bar (brown line L,

mixed line E, blue line N)

47
Figure 20-2

20.3
The installation of connection wires of spoke
Refer to the number, connect one end of spoke wire to the stretched wire of slip ring of revolving door
center, and connect the other end to the adaptor of main control box through the spoke.
Notice: Spoke wires after connection should be lay in the spoke groove and fixed with bonding wire
and sticking piece.

20.4
The installation of revolving door’s radar

1. To fix radar on the bracket with M4×16 inner hexagon screws, and ensure the radar detector to be

gradient outwards the door area.

2. To fix bracket on the canopy ring with M6×20 outer hexagon screws

3. According to the number (J06), connect one end of extension wire to radar and the other end to side
socket of main control box.
4. To install the other three radars in the same way mentioned above.

Figure 20-3

20.5
The installation of anti-squeezing sensor

1. To fix anti-squeezing sensor on the bracket with M4×16 inner hexagon screws.

2. To fix bracket on the canopy ring with outer hexagon screws.


3. According to the number (J04), connect one end of sensor extension wire to radar and the other end to
the side socket of main control box.

48
Figure 20-4

20.6
The installation of anti-strike sensor
1. To fix the anti-strike sensor to the bigger ceiling supporting ring in front of revolving wing.
2. Connect four-core wires, white, brown, green and yellow with 1,2,3,5 separately.

Figure 20-5

20.7
The installation of operation panel

1. To fix panel tray on the right side column of the inner opening with 4 pieces of M4×16 inner hexagon

screws (Figure 20-6).

2. To fix panel on the panel tray with M4×16 inner hexagon screw.

3. To fix one end of panel wire to main control box and the other end to the installation place of panel from
the top of inner-side column and through the hole. the wiring diagram refer to Figure 20.

Figure 20-6

49
20.8
The installation of handicap button
1. To fix handicap button panel tray on the right side column of the inner opening and outer opening with 4

pieces of M4×16 inner hexagon screws.

2. To fix handicap button panel to the panel tray with M4×16 inner hexagon screw.

3. To fix one end of panel wire to main control box and the other end to the installation place of panel from
the top of inner-side column and through the hole. the wiring diagram refer to Figure 20.

Figure 20-7

20.9
The installation of UPS

1. To fix UPS bracket on “H ” beam with 4 pieces of M8×40 inner hexagon screws.

2. To place UPS flatly on the bracket, and to fix the fixing strip on the bracket with M6×20 inner hexagon

screw, figure 20-8.


3. To connect UPS input wire to C05 socket of patch panel, and to connect output wire to C14 socket.
4. Please ensure the ground wire of UPS box and door body well-connected.

Figure 20-8
20.10 The installation of safety beam
To plug safety beam adapters into
the adapters from the hole of safety beam, and then put

50
the safety beam into installing hole properly.

Figure 20-10 shows the position of one side’s safety beam after installation.
(Single numbers indicate transmitting, and double numbers indicate receiving). Figure 20-9
G1, G6, G7 are the installed positions of anther side revolving wing. G10, G13, G16 are the positions
of showcase.

Figure 20-10
To lead wires of 6 sets of safety beam to safety beam control box along the wire groove located on “H”
beam inner side.
The order from left to right is: G2, G1, G10, G9, G6, G5,
G14, G13, G8, G7, G16, G15. (Figure 20-14)

Figure 20-14
Figure 20-14

21. The installation of electro-mechanical lock.

It is optional, if no this item, please skip.

21.1
To check electro-mechanical lock, and confirm the normal condition and wiring of electric-mechanical
lock.

21.2
To fix electro-mechanical lock to the lock board. (Figure 21-1)

51
Figure 21-1

21.3
Install electro-mechanical lock on the bracket which located on the top of left mullion in the inner opening
(Figure 21-2). Screw out two fixing screws of bracket and “Z shape” supporting rack first, and install the
lock on the bracket, re-twist the screws. (Don’t screw too tightly.)

Figure 21-2

21.4
To fix lock bank on connection board of accessorial wheel that locates on the top of revolving wing’s back
mullion. (Figure 21-3) To screw out two connection screws of two ends of the accessorial wheel, and to
place the lock bank on the connection board of accessorial wheel, and to re-twist screws.

52
Figure 21-3

21.5
To push the revolving wing to the door-locked position, stretch the dead bolt by switch. Adjust the placing
angle of lock installation board to ensure the radial position of electric-mechanical lock by oval-shaped
hole of the bracket and board, to make dead bolt in the lock bank. Then twist the two fixing screws tightly.

Figure 21-4

53
22. The installation of glass

22.1
The installation of curved glass of sidewall segment
22.1.1
To place 2 pieces of glass gaskets (4mm) into glass groove of lower curved frame of the sidewall segment
that locates 100mm from two mullions. To place 3 pieces of glass gaskets in the both outer mullion groove
(not for middle mullion with pinch plate), fixed with two-side glue. (Figure 22-1)

Figure 22-1

22.1.2
To place stow-wood on the floor inside entrance as support. Please install the glass to the specified position
by glass suck disc and check the equal space of two sides of glass.
22.1.3
To put pinch plate into the middle mullion and beat the other side with the rubber hammer from one end to
the other end slightly. While beating, someone else push the back of the middle mullion to prevent
shape-changing.
22.1.4
The installation of glass rubber strip. It should be 30-50mm longer than the length of the frame. To install
the level strip first, then the upright one. The upright strip presses on the level one. To place the upright

strip to 45°and spurt glass with soap liquid, insert the two ends first, then the middle. Notice: Don’t stretch

the glass rubber strip. (Figure 22-2),the same method to install others glass rubber strip.

54
Figure 22-2

22.1.5
To check the appearance of stripe: no sinking, no scrolling.

22.2
The installation of curved glass of revolving wing
The same way with installation of sidewall glass

23. The installation of safety rubber in the opening

To insert 4 pieces of safety rubber into 4 mullions located in the doorway separately (Figure 23-1). Refer to
the installation method of safety switch.(see the section 16.2).

Figure 23-1

24. The installation of top ring

To place 4 pieces of top ring on the brackets along the midline of the entrance symmetrically, and the 4

pieces are the same(Figure 24-1). To fix the top ring on the bracket with 10 pieces of fixing board(Figure

24-2). Connect each fixing board to top ring with two sets of M8 x 22 inner hexagon screws and spacers.

Connect to the bracket with a set of M8X30 inner hexagon screws, 2 spacers, spring spacers and nuts.
Don’t tighten the all screws firmly.

55
Layout of position of A

Figure 24-1

24.2
In the middle of entrance , to connect the 2 pieces of top ring with 2 pieces of fixing board on the side, and
each fixing board is fixed with 2 sets of M8x22 inner hexagon screws and spacers. Don’t screw them
tightly. To connect 2 pieces of top ring with 2 pieces of fixing board on the bottom, and each fixing board is
fixed with 4 sets of M8x22 inner hexagon screws and spacers. Don’t screw them tightly (figure 24-3).

24.3

To connect the top ring and canopy ring with 2 sets of canopy ring’s connection board 、adjustable screw 、

nut(3 pieces ). (Figure 24-3). Don’t tighten the nuts firmly.

56
24.4

To adjust the joint of top ring≤0.3mm,the distance between the top ring’s

Upper level and ceiling supporting ring’s lower level is 340 mm, and then tighten them firmly.
Layout of position B

Figure 24-2

25. The installation of the ceiling

There are two kinds of ceilings: nonmetal and metal. Please select the installation methods according to the
material:

25.1
Install the nonmetal ceiling
25.1.1
Check the ceiling and decorative strip , to confirm the appearance is completed.
25.1.2
The ceilings of KA022 have 14 sections. Positions as shown in figure 25-1.
To place the ceiling and decorative strip of ceiling on the position, there are 3 kinds of decorative strip,

located at the ①、②marks of figure25-1, the section drawing of decorative strip as shown as figure 25-2,

each decorative strip is connected to ceiling with 2 pieces of ceiling’s sealed strips. The installation
numbers of the ceiling are from No.1 to No.7 to place the ceilings on the two ceiling support ring (bigger

57
and smaller) and support strip of ceiling on the upper of sliding door and showcase. After finishing the
No.2 ceiling, install the short support strip of ceiling on the upper of showing door, Refers to the figure
25-3, to fix the short support strip of ceiling on the 2 pieces of connection board which located on the
bottom of main beam (for door diameter 42 and 48, fix one end to the connection board, the other end is
fixed to the main beam with 10mm thickness spacer) , and then, install the ceilings from No.3 to No.7 .
After finishing one ceiling, thread out the line from the hole of decorative lamp. The other installation
method is the same with above steps.

Figure 25-1

Figure 25-2

58
Figure 25-3

25.1.3
To check the ceiling. The appearance of ceiling is without white stubble and double-face tape , and the gap

between the two ends of decorative strip and ceiling support ring( bigger/smaller) <0.5mm。

25.1.4
Installation of fixing plate
There are two kinds of ceiling fixing plate, refer to figure 25-1 , the sectional plane of A point as shown in
figure25-4 , totally are 28 points; the sectional plane of B point like figure 25-5 , totally are 18 points.

25.2
25.2.1
The overall position of ceiling refers to the figure 25-1. The installation order is the same with this figure.
After finishing one ceiling, thread out the line from the hole of decorative lamp.
25.2.2

To check the gap of ceiling <1mm

25.2.3
Installation of fixing plate
It is similar with the nonmetal ceiling fixing plate, the only difference is adding the spacer under the fixing

59
plate.

26. The installation of the bottom board of the showcase

Refer to the figure 26-1, install the bottom board of showcase.

Figure 26-1

27. The installation of sliding door’s radar and decorative lights

27.1
The installation of sliding door’s radar
Get the sliding door’s Rader, connect the 4-core wire from longitudinal direction of “H” beam with
radar’s terminal , white wire with terminal 1, brown wire with terminal 2, green wire with terminal 3,
yellow wire with terminal 4 (Figure 27-1).
Notice: 1. To ensure 4-core wire and terminals well-connected.
2. This is applied only for metal ceiling.

Figure 27-1
To lead the wire through the installing hole, and place the radar upward in the hole of the ceiling (terminals
facing doorway). To make the hole of radar’s black bracket meet the fixing hole of ceiling. To fix radar on

60
the ceiling with 2 pieces of M4×12 (Figure 27-2).

Figure 27-2

27.2
The installation of the decorative lights
Draw the 12 pieces of light transformer wires on the main beam from the ceiling holes. Take the spotlight
and plug into the two connectors. Press the clasp and put the light into the hole vertically.

Figure 27-3 Figure 27-4


Loosen the clasp. Please lock up the clasp behind the hole of decorative lights. (Figure 27-4 shows the
upper of the ceiling).

28. Debugging illustration

The illustration introduces the debugging method and attention items. To ensure the normal operation,
please debug the products according to the following steps. Otherwise may cause product can’t work
properly, even occur serious accident.

Notice: the 28(Ⅰ) is the debugging method of SIEMENS system ,and the 28(Ⅱ) is the debugging

method of PANISONIC system, the no mark (Ⅰ) and (Ⅱ) is all-purpose ,when debugging please

choose the corresponding one.

28 (Ⅰ) the debugging of SIEMENS system

28.1

(Ⅰ) Connect all the components to the relevant wires. After checking again, tidy up and fix them.

28.2

(Ⅰ)Check the insulating resistance between the input power supply (AC220V) and door body should be

61
more than 1 M Ω, ensure it’s no short circuit of live line & null line. Check and ensure there’s no short
circuit between the DC 24V power supply module and door body. DC 0V power supply module should be
well-connected to door body. Grounding protection is required for door body. Please check all the
connections if found any abnormalities.
28.3

(Ⅰ)Check and ensure power supply is AC 220V±10%, 50Hz, 10A, and no heavy inductance in loop.

28.4

(Ⅰ) Turn on the power and check the validity of each input signal according the following Form.

Physical meanings of CPU port:


CPU INPUT SIGNAL
No. Signal origin function 1 remarks
1 I0.0 handicap button
2 I0.1 Program selector “1”
3 I0.2
4 I0.3 speed-down sensor
5 I0.4 Brake sensor
6 I0.5 Reset
7 I0.6 A pulse
8 I0.7 B pulse
9 I1.0 safety beam (photocell)
10 I1.1 unlocking position
11 I1.2 inner and outer anti-strike sensor signal
12 I1.3 electricity current limit
13 I1.4 inner and outer radars
14 I1.5 Program selector “5”
15 I1.6 Program selector “6”
16 I1.7 UPS fire alarm signal
17 I2.0 Program selector “2”
18 I2.1 Program selector “3”
19 I2.2 Program selector “4”
20 I2.3
21 I2.4 ‘Z’ pulse
22 I2.5
23 I2.6 function selectable signal
24 I2.7 emergency button
CPU OUTPUT SIGNAL
25 Q0.0
26 Q0.1 Sliding door partial open
27 Q0.2 Sliding door radar
28 Q0.3 Malfunction display signal L4

62
29 Q0.4 Electronic lock
30 Q0.5 Malfunction display signal L3
31 Q0.6 Malfunction display signal L0
32 Q0.7 L1 Malfunction display signal L1
33 Q1.0 Operation signal
34 Q1.1 Reverse signal
35 Q1.2
36 Q1.3 Electronic signal
37 Q1.4 Malfunction display signal L2
38 Q1.5 high speed/ low speed
39 Q1.6 sliding door full open
40 Q1.7 Decelerator
28.5

(Ⅰ)The data check and transducer parameters setting

Replace the SDP display plate by BOP control plate. Press “P” to go into parameter setting mode and

then the LED displays the present parameter. Use the button “△”and “▽” to increase or decrease the data.

Then press the button “P” to save data.

BOP operation panel

SDP display panel


Notice: These parameters are based on the drive unit which is made of quadruple AC motor (name
plate indicates “240v, 0.37KW”) and decelerator (decelerated rate is 10.5: 1). The parameters of the
other motors need extra adjustment.
Reference value of transducer parameters:

1、 P0010=30,P0970=1

2、 P0010=1

3、 P0100=0

4、 P0300=1

63
5、 P0304=240

6、 P0305=1.8 * 2

7、 P0307=0.37 * 2

8、 P0308=0.8

9、 P0309=0.8

10、 P0310=50

11、 P0311=1400

12、 P0640=300

13、 P0700=2

14、 P701=1

15、 P702=12

16、 P703=4

17、 P731=53.3

18、 P1000=2

19、 P1080=12

20、 P1082=50

21、 P1120=2.0-4.0

22、 P1121=1.0-2.0

23、 P1135=0.3-1.0

24、 P1300=0

25、 P1310=50

26、 P1311=50

64
27、 P1312=150-200

28、 P3900=3

29、 P1910=1

28.6

(Ⅰ) Adjustment of parameters

Refer to the following Figure of TD200 profile: 9 buttons and 1 LED display
LCD

SIEMENS TD200

F5 F6 F7 F8
F1 F2 F3 F4

SHIFT ESC ENTER

TD200 panel
There are two operating mode: operating mode and parameter editing mode. The system runs under
operating mode automatically when power on. Observe every stop position by adjusting program selector
and record the distance (unit: mm) between actual stop position and standard one. Press the button “F5/F1”
and read the message on LCD display “amend parameter”. Press “ENTER” and input the password
according to register message. Input the parameter number and amend the parameter.
Parameter sequence refers to the following form:
No Variable name Remarks
1 Activation position of maintaining message 1. Revolving door adjustment: Adjust the deflection on
2 Stop on the lock position stop position.
3 Stop on the Opening position 2. Sliding door adjustment: Adjust the stop position error.
4 Revolving door adjustment 3. PDR brake reference point: PDR position.
5 Sliding door adjustment 4. PDR braked scope: PDR effective scope
6 Malfunction diagnosis time: from sending 5. Safety beam (photocell) reverse scope: safety beam
normal operation signal to cannot start-up effective scope.
7 Alternation time of revolving and opposite 6. Malfunction diagnosis time: time between sending
revolving: from the stop of revolving to the normal operation signal and cannot start-up
beginning of opposite revolving. 7. Alternation time between revolving and opposite
8 Safety beam (photocell) reverse scope revolving: time from the stop of revolving to the beginning
9 Reorientation and emendation of opposite revolving.
10 Malfunction diagnosis time 8. Opposite revolving time: operation time of opposite
11 Restart time revolving
9. Restart time: from the end of opposite revolving to the
12 Opposite revolving time
beginning of revolving
13 Restart times

65
14 Alternation time between revolving and 10. Restart times: times of system trial-start
opposite revolving
The LCD display shows one amendable parameter every time. The parameter information is shining until
enter into editing mode. Press “Enter” to enter into editing mode. Let the cursor stop on the parameter.
When the parameter is not shining, amend it by pressing the button “ ” or “ ”. Press the button “ ” or
“ ” one time to change the parameter 1 pulse. For different diameters of doors the distance and the
relevant pulse is as following:
Diameter pulse distance
3.6m 1 8mm
4.2m 1 9mm
4.8m 1 10.5mm

(For example: The parameter “POSITION_1” for the doorФ3.6M is 435, and the distance to the standard

stop position is 40MM. Then there is 40/8=5 pulse needed to add to the parameter. So adjust it to 440.)
Adjust each parameter to reasonable value based on the relevant report of distance. Press “ENTER” to exit
editing mode.
For example:
1. Set the door to stop in the lock position
Press F1/F5 to activate parameters.
Press “ENTER” and input the password “1111” if needed, then amend the second parameter.
Press “ENTER”, amend the parameter to the required stop pulse value.
Press “ENTER” to exit editing mode.
1. Reset and amend parameter:
(1) Put the selector to position “2” (For KA023: Put the switch to the position “ON”.), press the
emergency button when the door runs to the panic break-out position (For KA023: the lock position). Push
the door wings to the required stop position manually. Press the button F1/F5 to activate the information
and amend the ninth parameter.
(2) Set the parameter to be “1”.
(3) After 15 seconds, release the emergency stop button. This position would be the “0” position and to
reset all the other stop positions.
(4) The automatic adjustment is over when the door stops near the opening position.
(5) Check each stop position and adjust the relevant parameters if needed.
(6) Check up the effective scope of the PDR and the safety beam (photocell) respectively. Adjust the
relevant parameters if scope changes are needed.
(7) Adjustment is over.
Notice: The door would amend some parameters and adjust the stop position automatically after the
first power on or reset parameters. It is normal that the stop position is random in the preliminary
revolving. The door would stop in the opening position when the adjustment is over.
28.7

(Ⅰ) Meanings of digital display (○: light)

Relevant meanings
code Q0.3 Q0.5 Q0.7 Q0.4 Q0.6

66
01 ○ Position_1 in Lock position

02 ○ Position_2 operating in opening position

03 ○ ○ Position_3 operating in closing position

04 ○ Position_4 continuous revolving

05 ○ ○ Position_5 manual positive direction

06 ○ ○ Position_6 manual opposite direction

07 ○ ○ ○ sliding door

10 ○ decelerated sensor

11 ○ ○ brake sensor

12 ○ ○ anti-squeezing PDR

13 ○ ○ ○ Safety beam (photocell)

14 ○ ○ Emergency button

15 ○ ○ ○ Fire alarm or power cut

16 ○ ○ ○ Handicap pressed

17 ○ ○ ○ ○ high current protection

20 ○ radar

28

(Ⅱ) the debugging of PANISONIC system

The control unit is consist of a PLC, a inverter drive and a tri-phase DC motor, and combine with the

touch-screen to do the system debugging. Refers to Figure28(Ⅱ)-1.

67
Mode switch inverter
变频器

Notice: don’t plug with power on between PLC


注意:
and PLC 与触摸屏之间的
touch-screen, to avoid to communication
portal of PLC and touch-screen.
插头不能带电插拔 以防损

1
2
3
KBB 4
凯必盛 5
6
7
8

Fi 28( Ⅱ ) 1
When the installation is completed, inspect the wire and the adaptor; connect the communication wire of
touch-screen and PLC after confirmation. Turn on the mode switch on the PLC to “RUN”; refer to

Figure28(Ⅱ)-1, then switch on UPS power.

28.1
(II) Adjust the parameter of the transducer
Notice: Please press the emergency stop button, and then switch on UPS power

TRANSDUCER PANEL AS SHOWN AS FOLLOWING FIGURE:

68
Please follow the steps shown below to adjust the parameters; the rest parameters are default value.
1. Make sure the transducer is in inactive position, the screen shows “000”.
2. Press “MODE” button (3 time), the transducer in on set position, the screen shows “P01”’
3. Press or button, the screen will show one of the functional numbers, which could
find out from the table shows below;
4. Press “SET” button to show the parameter “Pxx”;
5. Press or button to increase or decrease the data same as the enactment data’
6. Press “ SET” to save the data;
7. The screen will show next data. Follow steps “3,4,5,6” to set other data. Press “ MODE”
button, the transducer turns to “ Output frequency-Output electric current,” and then the
transducer start to work.
Data Function Extension Parameter
P66 Initialization 0.1 1

Fr First frequency(Hz)—low speed 0.1~50 12

P01 First accelerated time(s) 0.1~999 1.5


P02 First decelerated time(s) 0.1~999 1.5

P05 Increase of moment(%) 0~40 10

P07 Thermal electric current 0.1~100 Rated electric current


P08 Select order 0~5 2

P09 Frequency setting(Hz) 0~5 1

P12 Stop frequency 0.5~60 1


P13 DC apply the brake time 0~120 1.5
P14 DC apply the brake electrical level 0~100 50
P20 Select SW2 function 0~7 7

P32 Second frequency(Hz)—high speed 0.5~250 28

P40 Second decelerated time (s) 0.1~999 0.5


P47 Limit electric current function (s) 0.1~9.9 0.1
P50 Waiting time (s) 0.1~100 5
P51 Select restart 0~3 3
P52 Restart times 1~10 1
7 kind of
P64 Carrier frequency 10.0
selection
28.2

(Ⅱ)The adjustment of motor turning direction and the setting of low speed and high speed.

69
28.2.1

(Ⅱ)The adjustment of motor turning direction.

First, press the emergency stop button, and then remove motor belt.
Turn the functional switch to revolving position and program selection switch to position 4, remove
emergency stop button to make motor operate. Observe turning direction of the two motors, and adjust the
wiring to make the motors revolves anti-clockwise.
Notice: The adjustment of wiring should be done after cutting UPS for at least 5 minutes,
otherwise may cause electric shock and death.

28.2.2

(Ⅱ)The setting of low speed and high speed.

Cut the UPS and mount the motor belt. Connect UPS and turn program selection switch to position 4.
Activate repeat to make door revolves at a high speed. Observe the high speed is qualified or not. If
qualified, do none adjustment and skip to B item to continue. If is not qualified, press emergency stop
button to adjust the second speed frequency P32 of the transducer. To repeat the process “ release
emergency stop button and observe high speed—press emergency stop button and adjust high speed
frequency until high speed is qualified.
Release emergency stop button, the revolving door should be rotate continuous ,If it is qualified, do none
adjustment. Skip to the third item to continue. If doesn’t meet the requirements, adjust the first speed
frequency Fr of transducer after pressing the emergency stop button. To repeat the process “release
emergency stop button, press handicap button and observe low speed---press emergency stop button and
adjust low speed frequency, until the low speed meets the requirements.
28.3
(II) The adjustment of the connection wire of coder A and B and settings of system offset.

KA021
凯必盛 KA022

Figure-1 Figure-2

KBB

Lock position 0

Model
Opening position 1 锁门位 0
状态

Opening position 2 开门位 1 0 下页 Next page


70
Figure -3

Closing position 1
Up page

Closing position 2 关门位 1 0 上页

关门位 2 0
锁门优先 下页
Next page
Lock is priority

Figure -4

Braking delay
Up page
制动延时 0
Current position 上页

当前位 0 下页 Next page


Offset

Figure -5

Max balance position 1


Up page
疏散位 1 0
Max balance position 2 上页

疏散位 2 0 状态 Model
Anti-squeezing position

Figure -6

Fire alarm
Emergency stop

急停 火警 设定
Set
Braked safety beam
制动电子眼 下页
Next page

Figure -7

Up page
Overload of transducer 71
变频器过载 上页

Safety switch 安全开关 设定 Set


Figure -8

There are 8 interfaces on the touch screen. The relations between them are shown below:

KBB “KA021 Model Figure -7


Figure -1 Figure -2 Figure -3
Next page Figure -4

Set Figure -3 Up page Figure -7


Figure -7 Figure -8
Next page Figure -8 Set Figure -3

Up page Figure -3
Up page Figure -4
Figure -4
Figure -5
Next page Figure -5
Next page Figure -6

Up page Figure -4
Figure -6
Model Figure -7

1. The adjustment of the connection wire A and B of the coder


Turn the function switch to the revolving door position and program option switch to 6, and press the
reset button to make the door revolve anti-clock at a low speed. Please change the interface of touch screen
to Figure-5, and observe whether the changing trend of the number corresponds to the “current position” is
upward. If it is upward, do none adjustment and skip to item 2 to continue and if the trend is downward,
exchange wire A and B of the coder.
Notice: For the consideration of safety, cut off the power before exchanging the wires, and
reconnect UPS after adjustment.
2. The setting of system offset
Turn the functional switch to the revolving position, and turn the program selection switch to 6. Press
the reset button to make the door revolve anti-clock at a low speed. When the door revolves at least a circle

and reaches at the max balance door position (the “current position” of interface in Figure-5 should be<

72
512, otherwise revolve at least 180°and seek for max balance position one more time), release reset button

and then input the numbers that “current position” corresponds into the numbers that “offset” corresponds.
The details: take down the numbers that “current position” corresponds firstly, and then touch the number
that “offset” corresponds. Figure 9 shows the keyboard on the surface. Press the numbers that “current
position” corresponds one by one, and then press ENTER.

Figure -9

28.4
(II) The adjustment of lock position, opening position, closing position, max balance position and
anti-squeezing distance, see figure-10.

Max balance position1 Max balance position 2

Opening positon1 Opening position2

Closing position1 (lock position) Closing positon2

73
Figure -10

1. The adjustment of lock position: Turn program selection switch to 1 (Notice: the personnel in charge
of adjustment should not be in the revolving door to prevent to be locked in). The automatic door should
stop at the lock position. The adjustment personnel will observe outside the door. If the deflection is in the
allowed scope, do none adjustment and skip to item 2 to continue. If the deflection is not qualified, turn the
program selection switch to 2. When the door revolves to opening position, press the emergency stop
button, the personnel will go into the door to do adjustment. Input the deflection value to the numbers that
“lock position” corresponds. The adjustment scope: -15 pulse to +15 pulse. Repeat the above steps until the
lock position is qualified.
2. The adjustment of opening position 1 and 2: After adjusting lock position, turn the program
selection switch from 1 to 2. The door should stop at opening position (opening position 1 or2), and now
activate radar time for time to make the stop position exchange at opening position 1 (The “current

position” shown on Figure 5 <512) and opening position 2 (The “current position”>512). Observe the

opening position 1 and 2 respectively to see whether the closing position is qualified. If it is qualified, skip
to item 3. If it is not qualified, press the emergency stop button and then touch the numbers that opening
position 1 and 2 corresponds on the touch screen to do adjustment work. The adjustment range: -15 pulse to
+15 pulses. After the adjustment, release emergency stop button and activate the radar to see whether the
stop position is qualified. Repeat the above steps until the deflection meets the demands.
3. The adjustment of closing position 1 and 2: Turn the program selection switch to 3 (Notice: the
adjustment personnel cannot be in the door to prevent to be locked in). Activate the radar to make the door
revolve and stop the door at closing position (closing position 1or 2). Activate the radar time by time to

exchange the stop position at position 1 (The “current position”<512) and position 2 (The “current

position”>512). The adjustment personnel will observe outside the door. If the deflection is in the allowed

scope, do none adjustment and skip to item 4 to continue. If the deflection is not qualified, turn the program
selection switch to 2. After the door stop at opening position, press the emergency stop button to do
adjustment work. Touch the number that closing position 1 and 2 corresponds on the screen (screen
figure-4) and input adjustment value. The adjustment scope: -15 pulse to +15 pulse. Repeat the above steps
until the deflection of closing position 1 and closing position 2 meets the demands.
4. The adjustment of max balance position 1 and 2: When at closing position 1 and 2, turn the program
selection switch to sliding door position, the door will stop at max balance position (balance position 1 or

2).The “current value” of balance position 1<512, and the “current value” of balance position 2<

512.Observe the deflection and see it whether in the allowed scope. If the deflection is in the allowed scope,
do none adjustment and skip to item 5 to continue. If it is not qualified, touch the number that balance
position 1 and 2 corresponds on the screen (screen figure-6) and input adjustment value. The adjustment
scope: -15 pulse to +15 pulse. Turn the functional switch to the revolving position and program selection
switch to 3. Turn the functional switch to the sliding position when at stop position, closing position 1 and
closing position 2. Observe the whether the deflection of balance position 1 and balance position 2 is in the
allowed scope. Repeat the above steps until the deflection of balance position meets the demands.
5. The adjustment of anti-squeezing distance: Turn the operation way to revolving position and

74
program selection switch to 4, and activate anti-squeezing PDR. Observe the anti-squeezing distance is
qualified or not when the door stops. If is qualified, do none adjustment and skip to item 6 to continue. If it
is not qualified, touch the number that anti-squeezing corresponds on the screen (screen figure-6) and input
adjustment value. The adjustment scope: -15 pulse to +15 pulse.
Leave the anti-squeezing sensor in the state of no activation and active the anti-squeezing sensor again
when the door revolves through the anti-squeezing area. Observe the anti-squeezing distance again when
the door stops. Repeat the above steps until the deflection of anti-squeezing PDR meets the demands.
28.5
(II) Condition display
You can observe the condition of emergency stop button, fire alarm signal, braked safety beam and
safety switch and the overload of transducer. Exam the wiring is right or not.
Appendix-A the meanings shown on LCD

Code Corresponding meanings remarks

01 “1” –locking

02 “2”-start at opening position

03 “3” - start at closing position

04 “4” - continuous revolving

05 “5” - manual clockwise

06 “6” - manual anti-clockwise

07 Sliding door
10 speed reduction safety beam
11 Braked safety beam
12 Anti-squeezing PDR
13 Safety switch
14 Emergency stop button
15 Fire alarm or power cut
16 handicap button pressed
17 Overload protection
20 radar
00 Be adjusting
21 sliding door radar
22 sensor
3X remote control mode

31 “1” –locking

75
32 “2” –start at opening position

33 “3” - start at closing position

34 “4” -continuous revolving

37 Sliding door function/sliding door opening/ sliding door half-opening

28.6

(II)The PRI setting of lock and fire alarm

As customers’ request, we set the PRI relations of lock and fire alarm in the surface shown as Figure-4.
If the PRI of locking: no matter how the fire alarm is, the door stops at the lock position when functional
switch is turned to revolving position and PSA is turned to 1. The door will not revolve when radar is
activated. If the PRI of fire alarm: no matter the condition of functional switch and PSA (including lock
condition), the door will stop when revolves to sliding door position and the sliding door will half open
automatically.
28.7

(Ⅱ) Physical meaning PLC terminals:

PLC FPO-32T input signal terminal


No Signal adds Function instruction Through slip ring Remarks

1 X0 N
PIC-RDY

2 X1 N
PIC-DATA

3 X2 N
PLC-RDY feedback signal

4 X3 A pulse N
5 X4 B pulse N
6 X5 Z pulse N
7 X6 speeding reduction safety beam Y
8 X7 braked safety beam Y
9 COM Ground wire N
10 COM Ground wire N
11 X8 Safety switch Y
12 X9 Inner/outer PDR signal N
13 XA Inner/outer radar N
14 XB currency limit Y
15 XC fire alarm signal Y
16 XD Manual button N
17 XE handicap button N

76
18 XF emergency stop button N
19 COM Ground wire N
20 COM Ground wire N
FPO-E8X input signal terminal
21 X0 N
Program selector“1”

22 X1 N
Program selector “2”

23 X2 N
Program selector “3”

24 X3 N
Program selector “5”

25 X4 N
Program selector “6”

26 X5 Program selection signal N


27 X6 Program selector N
28 X7 Program selector N
29 COM Ground wire N
30 COM Ground wire N
FPO-32T output signal terminal
31 Y0 N
PIC-RDY

32 Y1 N
PIC-DATA

33 Y2 communication power signal N


34 Y3 malfunction display signal L0 N
35 Y4 malfunction display signal L1 N
36 Y5 malfunction display signal L2 N
37 Y6 malfunction display signal H0 N
38 Y7 malfunction display signal H1 N
39 COM(+) 24V Power supply Y
40 0V Y
COM(-)

41 Y8 Y
transformer signal—5

42 Y9 Y
transformer signal—6

43 YA Y
transformer signal—7

44 YB Y
transformer signal—8

45 YC sliding door radar Y


46 YD sliding door opening Y

77
47 YE sliding door half-opening Y
48 YF Brake unit Y
49 COM(+) 24V power supply Y
50 0V Y
COM(-)

28.1
Adjustment of radar detecting scope
28.1.1
Adjustment of radar
Adjust the radar detecting scope to be 2.5m. There are two adjustment methods:
(1) Adjust radar bracket to make radar outward gradient to be about 15° (eyeballing).
(2) Set DIP switch as following:
DIPSwitch ON OFF Set in factory
1 High sensitive Low sensitive ON
2 Passive way Initiative way OFF
3 OFF
Keep time:2s Keep time:0.5s

DIP switch layout(Figure28-1-1):


O

OFF 1 2 3

Figure 28-1-1

28.1.2

ADJUSTMENT OF ANTI-STRIKING SENSOR

To adjust the reaction height of anti-striking sensor through rotating the potentiometer(Figure 17-4)
anticlockwise. To adjust the reaction height of the anti-striking sensor to make the distance to lower
ceiling support rings of revolving wing should be ≥1500mm.

Figure28-1-2
Take off the panel, and adjust the position and ensure the radar’s sensitive height (between sensor and
ground) should be less than 100mm. Meanwhile, cover the anti-squeezing sensor, the revolving wing
should stop revolving, the distance between stop position and outer mullion should be more than 700mm.

78
Figure 28-1-3

Adjust potentiometer

28.2 Adjustment of automatic sliding door


28.2.1
Refer to Figure 28-2-1. To connect the stretched wires from PSA Terminal 1 and Terminal 2 with Terminal
25 and Terminal 26 (on the main board).

Terminal

25 26

1
2
3
4
Wiring layout of back PSA

Figure 28-2-1
28.2.2
Functions setting (the second class)
The functions are displayed by abbreviation words on the right side of the PSA control unit. Press the
button “+” or “-” to choose the required function. The function comes into effect when press the button “+”
and “-” at the same time. The setting of functions is indicated by splashing of LED. (High frequency = high
speed / short opening keep time) The buttons of “+” and “-” are used to amend the value of setting. (“+”:
faster and longer; “-”: slower and shorter)
There are two ways for returning to the first class: 1.Press the two buttons at the same time; 2. No
operation will be done within 1 minute on the PSA control plate.
1. Reset: LED 32
Resetting is to restart equipment. If operate “reset” in the condition of UPS battery power supply,
drive unit stops and control unit turns off.
2. Door opening speed: LED16
Adjustable opening speed: 40~100%; Standard: 100%
3. Closing speed: LED 8
Adjustable closing speed: 25~66%; Standard: 65%.
4. Opening width (winter): LED 4
Adjustable opening width: 25~90%; Standard: 65%.
5. Opening keep time (Standard): LED 2
Adjustable opening keep time: 0~10s; Standard: 2s.
6. Adjust keep opening time (night) (0~30 seconds) LED 1
Standard setting is based on the first operation of the door.
If execute order “reset” in the second class function, the setting such as opening speed, closing speed

79
and partial open will reset to standard setting.

28.8(Ⅱ) User’s instruction of remote control (only for panisonic system)

Select the “remote control” position on the Working mode selector, the automatic door will cancel the
former working mode automatically (At this moment, the working mode will base on the display of remote
control), automatic door should be operated through the remote control.
The operation steps are as following:

1 --------position1,when the digital tube is flashing, please press this key, loosen it after one second,
the data of this key will be sent. If the left digits of the digital tube are not 07 or 14, well then, the former
data will become 01.

2 --------position2, when the digital tube is flashing, please press this key, loosen it after one second,
the data of this key will be sent. If the left digits of the digital tube are not 07 or 14, well then, the former
data will become 02.

3 --------- position3, when the digital tube is flashing, please press this key, loosen it after one second,
the data of this key will be sent. If the left digits of the digital tube are not 07 or 14, well then, the former
data will become 03.

4 --------- position4, when the digital tube is flashing, please press this key, loosen it after one second,
the data of this key will be sent. If the left digits of the digital tube are not 07 or 14, well then, the former
data will become 04.

5 --------- position5, when the digital tube is flashing, please press this key, loosen it after one second,
the data of this key will be sent. If the left digits of the digital tube are not 07 or 14, well then, the former
data will become 05. Subsequently, press the RESET, the door will revolve anti-clockwise, loosen RESET,
the door will stop.

6 ------- position6, when the digital tube is flashing, please press this key, loosen it after one second,
the data of this key will be sent. If the left digits of the digital tube are not 07 or 14, well then , the former
data will become 06. Subsequently, press the RESET, the door will revolve clockwise, loosen RESET, the
door will stop.

7 -------handicap, when the digital tube is flash, please press this key, the door will revolve slowly,
loosen this key, the door speed will be order after one circle of low-speed.

8 -------sliding door/the change of revolving door, when the digital tube is flashing, please press this
key, the data of this key will be sent. If the left digits of the digital tube are not 14, well then, the former
data will become 07. The door will go to the position of sliding door. Alternate 30 seconds at least, the
digital tube is flash, press this key again, if the left digits of the digital tube are not 14, well then , and the
digital tube will display the new position, if the left digits of the digital tube are 14, the sliding states still be
canceled, but there is no display change. If the emergency stop is canceled, the digital tube will display the

80
new position.

9 --------light 1, when the digital tube is flashing, please press this key, loosen it after one second, the
data of this key will be sent. Before now, the lights of both groups will be not flashing (the right digits of
the digital tube are 90), at this time, the right digits of the digital tube will display 91, the frist group of
ceiling lights will be flashing; Before now, the lights of the second group have been flashing (the right
digits of the digital tube will display 92), at this time, the right digits of the digital tube will display 93. The
first group of ceiling lights will be flashing. Alternate 30 seconds at least, the digital tube is flashing, press
this key again, before it, if the second group of lights is not flashing, the right digits of the digital tube will
display 90; if the second group of lights is flashing, and the right digits of the digital tube will display 92. In
addition, under the state of non-controlled, we can also control the lights. The non-controlled state is that
select the revolving or sliding door position on the working selector.

10 -------light 2, when the digital tube is flashing, please press this key, loosen it after one second,
the data of this key will be sent. Before that, if the lights of both groups will be not flashing (the right
digits of the digital tube are 90), at this time, the right digits of the digital tube will display 92, the second
groups of ceiling lights will be flashing; Erenow, the lights of the first group have been flashing (the right
digits of the digital tube will display 91), at this time, the right digits of the digital tube will display 93.
The second group of ceiling lights will be flashing. Alternate30 seconds at least, the digital tube is flashing,
press this key again, Erenow, if the first group of lights are not flashing, the right digits of the digital tube
will display 90; Erenow, if the first group of lights have been flashing, at this time, the right digits of the
digital tube will display 91. In addition, under the state of non-controlled, we can also control the lights.
The non-controlled state is that select the revolving or sliding door position on the working selector.

11 -------emergency stop, when the digital tube is flashing, please press this key, loosen it after one
second, the data of this key will be sent. Alternate 30 seconds at least, when the digital tube is flashing,
please press this key again, the emergency stop will be canceled, at this time, if the door is not under the
state of sliding door, the digital tube will display the door are on the new position. Contrarily, the left digits
of the digital tube will display 07.

12 ------Reset, when the digital tube is flashing, and the left digits of the digital tube display 05 or
06, please press this key, the door will revolve clockwise, loosen RESET, and the door will stop.

13 ---------Display, before operating the door or check the operation state of controlling state, please
press this key , loosen it after about 1 second, the digital tube will display the latest results of operating the
controller, and the digital tube will be under the state of displaying. Contrarily, the digital tube will not be
under the state of displaying, please press the “displaying”.

14 ------- A、B、C,at present , the three keys are not available.


Attention:
A. please don’t press the keys continuously and apace, on the operation.

81
B. The Min. switch time is 1 second, the Max. Controlling distance is 30 m.
28.3
The adjustment of monitor control (optional)

Check the connection of communication board、mobile phone、antenna、data line and so on, switch on the

mobile phone , operate the PLC program , observe the power supply connection of the communication
board.
28.3.1
According to the “remote control and states inquire” flow, check functions.
Remote control and states inquire flow chart
Pick up the phone

Select language, Chinese -1, English-2 (once for each)

Consumer and products code (ten digits)

N
Please input password, press # key to end Because of mistake, please input the password again

Y Y
Romote operation, press 1 Check the state, please press 2, press # to end

Sliding door Revolving door Code operation, Status indication, Number of circles
operation, press 1 operation, press 2 press 3 press 1 press 2

Opening press 1
System normal Inquire sliding
Input
Closing press 2 Transducer trouble door press1
operation
Safety beam activation Inquire revolving
code, press
Lock door press 1 Safety switch activation door press2
# end
Emergency button press Press # end
Barrier trouble
Opening position startup press2 Inquire
System power off
product
Fire alarm
Closing position startup Input # *******times

Continues rotate press4

Put down phone after three


automatic repeats
82
XXXXXXXXXX operate,press * to confirm,press # to

cancel(receive*or other orders except* skip to the upper

Put down phone(receive* to confirm phonetic indication)


28.3.2
Remote alarm
When the door has malfunctions, it will send a short message to the manufacturer, the monitor server
will record the data and date, the alarm server will sound, and tell principal the problem.
When the short message is finished, the exchanged model will select the alarm number from the data
bag and dial this phone number automatically, when the line’s busy, power off or not in the service area, put
down the phone automatically and dial this number again after 10 minutes, when the line’s normal, tell
consumer, product code and the faults style in English and Chinese, when receive the confirmation * or the
canceling # from the other side, put down the phone automatically and confirm the alarm function. If don’t
receive the confirmation, the door will confirm the alarm failed, please dial this number again after 10
minutes.

29. The installation of decorative plate

The decorative plate should be installed after function adjustment. There are 6 or 7 pieces of decorative
plate based on different specifications (usually there are 6 pieces of decorative plates for metal decorative
automatic doors). The installation steps are similar. The difference is the locations of the decorative plates.

29.1
Check all the decorative plates and decorative plate strips. Make sure they are all in good condition.

Top ring

Decorative plate

Canopy ring

83
Figure 29-1

29.2
Put the decorative plates into the decorative plate grooves. Firstly, put the decorative plates into grooves of
the top ring decorative plate. Then, put them into grooves of the canopy ring decorative plate.

29.3
Manually push the decorative plates to the installation locations along the decorative plate grooves. There
are 2 pieces of short plates and 5 pieces of long ones for total the 7. Install the decorative plate strip to the
joint of each two decorative plates. Refer to Figure 29-2 that shows installation locations of the 7
decorative plates. There are 2 pieces of straight ones and 4 pieces of one-side-bend ones for total 6
decorative plates. Refer to Figure 29-3 that shows installation locations of the 6 decorative plates).

Decorative board Short decorative plate

室内
Indoor
Decorative plate strip

Magnify

放大

Outdoor
室外

Figure 29-2

Straight decorative plate

Magnify
放大
室内
Indoor

Outdoor
室外

Straight decorative plate 84


Figure 29-3

30. The installation of anti-dust plate

There are 6 pieces of anti-dust plates for size 36, and 8 pieces for size 42 and size 48. Refer to Figure 30-1.
Place the anti-dust plates on the top ring, then insert the anti-dust plate strips into joint of each two pieces
of anti-dust plates.

Figure 30-1

Figure 30-2

Top board Top board

85

Anti-dust plate strip


Figure 30-3

31. Final-stage maintenance

31.1
Disperse the black glass glue evenly between sidewall panels, door shaft tray and the floor.

31.2
Plaster the showcase glass with yellow caution labels – “Caution: Automatic Door”.

31.3
Peel the protective film and clear the door body, wings and the construction location.

32. Malfunction disposal

1) Treatment for simple malfunctions

malfunctions Reasons of malfunctions Treatment


Not connected to power supply Check it and connect it to power
Something in front of brake sensor Check and clear it
vertical safety switch works Check it up.
Be unable to Emergency button is pressed Release emergency button
revolve Anti-squeezing PDR works Check it up.
Check it up. If found block between revolving
Resistance on revolving wings
wings and floor or sidewalls, clear it.
Press reset button to let system self-diagnosis
Software malfunctions
again.
Revolving Check it. If found block between revolving
speed slows Resistance on revolving wings wings and floor or sidewalls, clear it. Check
down the brush seals.
Noise arise Friction between revolving wings and floor or
Avoid or reduce friction.
when works sidewalls.
2) Treatment for complex malfunctions
If there is malfunction which is not included in the form above, please inform our professional
personnel about the malfunction. We will settle your problem promptly and give you a satisfying answer.

86
Attached Form 1: Floor horizon measuring result

Measuring point Measuring value benchmark value Difference between benchmark and measuring value
1
2
3
4
5
6
7
8
9
10
11. benchmark
12
13
14
15
16
17
18
19
20
21
Result: □ qualification □disqualification

87
Attached Form 2: Entrance measuring value

Model Min. net width of entrance (B1) Max. net width of entrance (B2)

Min. net height of entrance (H1) Max. net height of entrance (H2) Unilateral vertical allowance (T)

Result: □ qualification □disqualification

Attached Form 3: ground track horizon measuring value

No. Measuring value


1
2
3
4
5
6
7
8
9
10

88
Only for SIEMENS system

Figure One

89
Only for PANISONIC system

Figure Two

90
Display 1: Main tools for installation process

Needle nose pliers Allen wrench

Wire cutters Hex key set

Multi meter Rubber mallet

91
Screw drivers Measuring tape

Surveyors level Glass suction disks

Stop watch Hammer drill

92
Open ended spanners Depth gauge

Power hand drill Vertical weight line

Clearance gauge Poke needles

93
Scissors Glass cement gun

Files

94