No exit meeting was held at the time the audit was concluded. Follow-up meeting to review non-
conformance and observations to be scheduled.
Observation: No formal process in place to issue supplier corrective action or how to preclude
the use of disapproved suppliers.
Requirement 7.4.2 Purchasing Information
Purchasing information shall describe the product to be purchased, including where appropriate
a) requirements for approval of product, procedures, processes and equipment,
b) requirements for qualification of personnel, and
c) quality management system requirements.
Finding: No evidence that adequate information covering these requirements is being flowed
down to suppliers of calibration services, especially in regards to ISO9001 7.6 a) requirement
“Where necessary ensure valid results, measuring equipment shall…
a) be calibrated or verified at specified intervals, or prior to use, against measurement
standards traceable to international or national measurement standards; where no such
standards exist, the basis used for calibration or verification shall be recorded;.” No
evidence that requirements are flowed down to calibration supplier to allow compliance to
requiring calibration “…against certified equipment having a known valid relationship to
internationally or nationally recognized standards.”
Requirement 4.1 General Requirements: and 7.4.2 Purchasing Information (see above)
Where an organization chooses to outsource any process that affects product conformity with
requirements, the organization shall ensure control over such processes. Control of such
outsourced processes shall be identified within the quality management system.
Finding: Methods of control for any outsourced processes such as embossing or calibration need to be
identified in the quality manual (see 4.2.2) or other documentation such as purchasing information.