Professional Documents
Culture Documents
Note:
1. Recommended torque values are based on using weld-neck (integral) flanges).
2. Bilnd other flange types may require different sealing loads.
3. Bolt Torque values listed assume a lubrecated stud bolt resulting in a 0.15 friction factor.
9
Torque Values for ICP Flange Insulation Gaskets
CLASS 1500
NPS Nº Bolt Dia. Suggested Torque
[inch] Bolts [in] Ft.Lbs. Kgf.cm
1 4 ⅞ 110 1521
1¼ 4 ⅞ 170 2350
1½ 4 1 240 3318
2 8 ⅞ 170 2350
2½ 8 1 240 3318
3 8 1⅛ 370 5115
4 8 1¼ 650 8987
5 8 1½ 1000 13826
6 12 1⅜ 820 11337
8 12 1⅝ 1400 19356
10 12 1⅞ 2100 29034
12 16 2 2300 31799
14 16 2¼ 3400 47007
16 16 2½ 4300 59450
18 16 2¾ 6200 85718
20 16 3 7800 107839
24 16 3½ 13000 179732
CLASS 2500
NPS Suggested Torque
Nº Bolt Dia.
[inch] Bolts [in]
Ft.Lbs. Kgf.cm
1 4 ⅞ 170 2350
1¼ 4 1 300 4148
1½ 4 1⅛ 400 5530
2 8 1 300 4148
2½ 8 1⅛ 400 5530
3 8 1¼ 600 8295
4 8 1½ 650 8987
5 8 1¾ 1500 20738
6 8 2 2300 31799
8 12 2 2400 33181
10 12 2½ 4900 67745
12 12 2¾ 7900 109222
Note:
1. Recommended torque values are based on using weld-neck (integral) flanges).
2. Bilnd other flange types may require different sealing loads.
3. Bolt Torque values listed assume a lubrecated stud bolt resulting in a 0.15 friction factor.
10