You are on page 1of 9

CONTROLLER COMMUNICATIONS

(MASTER/SLAVE & MULTIUNIT SYSTEMS)


GENERAL INFORMATION – LOGIK9

Logik9 has 1 RS485 serial communication port that allows to communicate under ;
• Master / Slave Mode : the communication between two compressors
• Multiunit : the communication between compressors up to 12 units
• Scada Systems : Logik9 can communicate with scada systems by using Modbus RTU
• Cloud Server : Logik9 can pass the information to cloud and user can follow the
compressor by using webbrowser
• Webserver : Logik9 and by using special ethernet serial gateway, user can observe the
compressor information on the webserver.
GENERAL INFORMATION – LOGIK26S

Logik26S has 2 RS485 serial communication ports. Second communication port can be used to
communicate with inverter driver itself.

The main communication port can communicate under the system described below;
• Master / Slave Mode : the communication between two compressors
• Multiunit : the communication between compressors up to 12 units
• Scada Systems : Logik26S can communicate with scada systems by using Modbus RTU
• Cloud Server : Logik26S can pass the information to cloud and user can follow the compressor by
using webbrowser
• Webserver : Logik9 and by using special ethernet serial gateway, user can observe the compressor
information on the webserver.

Note: If the compressor is not communicating with the driver, second RS485 port also can be used
to communicate with external modules & scada system as well.
GENERAL INFORMATION – LOGIK33S

Logik33S has 2 RS485 serial communication ports. Second communication port can be used to
communicate with inverter driver itself.

The main communication port can communicate under the system described below;
• Master / Slave Mode : the communication between two compressors
• Multiunit : the communication between compressors up to 12 units
• Scada Systems : Logik33S can communicate with scada systems by using Modbus RTU
• Cloud Server : Logik33S can pass the information to cloud and user can follow the compressor by
using webbrowser
• Webserver : Logik9 and by using special ethernet serial gateway, user can observe the compressor
information on the webserver.

Note: If the compressor is not communicating with the driver, second RS485 port also can be used
to communicate with external modules & scada system as well.
Communication / Master - Slave

Master / Slave communication functions :


• Balance Hours : Two compressors can be managed to balance the working hours
• Cascade working system with two compressors : By proper parameter settings user can
design cascade system where one compressor capacity is not sufficient to provide
pressurized air.
• Two inverter controller compressor can modulate at the same time by using special
inverter twin function (Logik 26S & Logik33S systems).

RS485 line RS485 line


Modbus Rtu Protocol Modbus Rtu Protocol

RS485 line
Modbus Rtu Protocol
LOGIK 33S – Communication / Multiunit

Multiunit Communication Functions:


• Logik33S also have multiunit function and can manage the compressor plant

Logik33S Multiunit

RS485 line Logik33S


Modbus Rtu Protocol

Logik9
Logik33S Logik26S

Up to 5 (1 is master) units can be controlled


LOGIK 200 – Communication / Multiunit

Multiunit Communication Functions:


• Balance Hours : the working hours can be balanced
• Priority : Its possible to assing to compressor a priority
• Smart Mode : According to air consumption, the multiunit system selects the energy
saving combination with the compressor capacities.

Logik200 Multiunit Controller

RS232-RS485
Converter

RS485 line
Modbus Rtu Protocol

Logik9 Logik33S Logik26S


Up to 12 units can be controlled
Communication / Ethernet Serial Gateway

Ethernet Serial Gateway:


• Embedded webserver mode: the compressor plant monitoring
• Cloud based mode : the compressor plant monitoring by using internet connection
• Modbus RTU -> Modbus TCP converter

Serial Ethernet Interface TCP/IP – WebServer Interface

Modbus RTU / Modbus TCP

RS485 line
Modbus Rtu Protocol Cloud – Server

TCP/IP – WebServer Interface

Logik9 Logik33S Logik26S

Up to 12 units can be connected


Thank You …