EM-103L
9/30/11

LF Vent Pac & Rod Temperature


Objective and Test Setup 
A test was performed on the Cook test compressor to compare heat generation of the 
LF Vent Pac versus that of BD and WAT vent rings. The compressor was run at 1200 RPM 
with a suction pressure of about 800 PSI and a discharge pressure of about 1150 PSI. 
The same set of pressure packing was used with all vent rings. The test ring was placed 
in the flange, immediately downstream from the vent. Five (5) each of the different style 
of vent rings were tested. 

Conclusion 
On average, WAT rings generate more frictional heat than either BD rings or the LF Vent 
Pac. In addition, BD rings generate more frictional heat than the LF Vent Pac. Average 
rod temperatures produced during the test are shown in the chart below. 

Frictional Heat Generation
250

245
Piston Rod Temperature, °F

240

235

230

225

220

215
WAT BD LF Vent Pac
Vent Ring
 