Professional Documents
Culture Documents
Air Air Cooler Air Cooler No. of Total Face Trim Cooling Water Trim Cooler Tube
Shell ID
Cooler Outlet Area/bun Bundles Area of Velocit Cooler Flow Area length
°F ft2 ft2 ft/min lb/hr USGPM ft2 in ft
AC-1 130 501.7 2 1003.4 365.4 - 0 0 0 0 0
AC-2 140 400.8 2 801.6 409.8 TC-2 2304 4.598 57.6 8 6
AC-3 150 328.6 2 657.2 387 TC-3 4882 9.743 123.2 10 8
AC-4 160 271.4 2 542.8 441.6 TC-4 7489 14.95 155 10 10
AC-5 170 234 2 468 400.2 TC-5 11000 21.95 186.8 10 12
AC-6 180 200.6 2 401.2 469.8 TC-6 12794 25.53 233.5 12 10
AC-7 190 170.9 2 341.8 495.6 TC-7 15490 30.92 281.4 12 12
AC-8 200 148.6 2 297.2 308.4 TC-8 18000 35.92 281.4 12 12
AC-9 210 126.3 2 252.6 352.2 TC-9 20500 40.91 281.4 12 12
45 1200
40
Air Cooler Bare Tube Area
& 1000
Cooling Water Supply Intersection
35
30 800
25
600
20
18 GPM
500 Ft2
15 400
10
200
5 170 Ft2
0 166°F 0
130 140 150 160 170 180 190 200 210
Air Cooler Outlet Temperatures (°F)
Cooling Water USGPM Trim Cooler Surface Area Total Bare tube Area
45 1200
35
30 800
Trim Cooler Surface Area (ft2) /
Total Air Cooler Area (ft2)
Cooling Water (USGPM)
25
600
20
15 400
280 Ft2
10
200
0 204°F 0
130 140 150 160 170 180 190 200 210
Air Cooler Outlet Temperatures (°F)
Cooling Water USGPM Trim Cooler Surface Area Total Bare tube Area