You are on page 1of 1

Site Conditions Considered*

1 Pressure : 1.033 kg/cm2 g

2 Temperature : 45 Deg C

3 Humidity : 95%

4 Capacity : 3000 Nm3/Hr

Calculations :

V m3/hr : V nm3/min X [ { ( 273 + Ts ) / 273} X {Pn / (Ps - Pvs.Rh.)} ]

Parameters :

1 V m3 / hr : Volune in m3/min to be calculated


2 V nm3/hr : Volume in nm3/min 50
3 Ts : Site Temperature 318
4 Pn : Nominal working Pressure 1.033
5 Tn : Nominal Temp 273
6 Ps : Site Pressure 1.033
7 P vs : Site Vapour Pressure 0.09596
8 Rh. : Relative humidity 0.95

( The Site Pressure and Pvs values are taken from Vapour Pressure Chart )

Actual Calculations :

V m3/min : V nm3/min X [ { ( 273 + Ts ) / 273} X {Pn / (Ps - Pvs.Rh.)} ]

: 50 X 1.164835 X 1.096792

: 63.88

V m3/min : 63.88

cfm : Vm3/min X 35.31

2255.57

cfm : 2255.57