You are on page 1of 1

Hydro-Flo Technologies, Inc.

The Art and Science... of Wastewater Treatment

Company
Location

USER INPUTS IN YELLOW


DESIGN FLOW RATE (IN GPM) 150.000
TEMPERATURE (IN DEGREES F) 60.000
SPECIFIC GRAVITY OF THE OIL (IN G/CM³) 0.900
OIL DROPLET SIZE (IN MICRONS) 30.000
MEDIA SPACING ( 0.5 0.75 or 1.20 ) 0.750

For more detailed information go to www.HydroFloTech.com

HOPPER BOTTOM 0.000 LIST OF OPTIONS


SKIMMER 0.000 MARK
COVERS 0.000 0 FOR NO
AUGER 0.000 1 FOR YES

MODEL NUMBER 132 - FB - NS - NC - NA

Call 630-762-0380 to talk to a Hydro-Flo application engineer

OUTPUTS IN BLUE
DENSITY OF THE WATER (IN G/CM³) 1.00
VISCISITY (IN POISE) 0.0113
RISE RATE OF OIL DROPLET (IN GPM/FT²) 0.0632
PROJECTED SURFACE AREA (IN FT²/FT³) 21
REQUIRED MEDIA VOLUME (IN FT³) 112.96
HORIZONTAL SERAPATOR AREA IN FT²
REQUIRED TO ACHIEVE DESIRED OIL
REMOVAL EFFICENCY 2372

Use the formula below if you know the degrees API but not the
specific gravity of the product to be removed
Conversion from Degrees API to Specific Gravity: Formula: Sw
= (141.5 / (API + 131.5))
DEGREES API 35.000
SPECIFIC GRAVITY 0.8498498498

Formula:
Qm / (AH * 7.48) = (j2 * 1.072 x 10 –6) (Sw - So) / m
Qm = design flow, in ft3
AH = horizontal separator area, in ft2
j = oil droplet diameter in microns
Sw = specific gravity of the wastewater
So = specific gravity of the wastewater’s oil phase
m = wastewater’s absolute (dynamic viscosity, in poise)