OUTPUTS IN BLUE
DENSITY OF THE WATER (IN G/CM³) 1.00
VISCISITY (IN POISE) 0.0113
RISE RATE OF OIL DROPLET (IN GPM/FT²) 0.0632
PROJECTED SURFACE AREA (IN FT²/FT³) 21
REQUIRED MEDIA VOLUME (IN FT³) 112.96
HORIZONTAL SERAPATOR AREA IN FT²
REQUIRED TO ACHIEVE DESIRED OIL
REMOVAL EFFICENCY 2372
Use the formula below if you know the degrees API but not the
specific gravity of the product to be removed
Conversion from Degrees API to Specific Gravity: Formula: Sw
= (141.5 / (API + 131.5))
DEGREES API 35.000
SPECIFIC GRAVITY 0.8498498498
Formula:
Qm / (AH * 7.48) = (j2 * 1.072 x 10 –6) (Sw - So) / m
Qm = design flow, in ft3
AH = horizontal separator area, in ft2
j = oil droplet diameter in microns
Sw = specific gravity of the wastewater
So = specific gravity of the wastewater’s oil phase
m = wastewater’s absolute (dynamic viscosity, in poise)