You are on page 1of 3

Sigma Paints Saudi Arabia Ltd.

Technical Specification
Kingdom of Saudi Arabia, Dammam Branch

Date: January 24, 2018 Project: AYASH Owner: #REF!


(Sub) Con: Al- AYASH FOR STEEL INDUSTRIES Location: KSA- King Khaled Airport PSGS index 072-00015-18 REV 03-1 System: 1
Area 1000 m²
Substrate type Carbon Steel carbon steel (blast Sa 2.5) TRUE Tank or pipe coating specification (internal)
Area description External Paint system for the steel tank- Steel Oil shop Fabricated Tanks. As per Aramco Engineering Standard APCS-1F
/ exposure
Tank / pipe Cargo type(s), dedicated (yes/no) Temperatu … °C to Cathodic Pressure … to … pH range … to …
internal service (use area disc. area for additional and re … °C protection range (MPa) MPa
Minimum Wash/degrease with fresh water (and if required detergent f.i. 0800 Sigma Paint Cleaner Degreaser), abrasive blast to minimum Sa 2½ according to ISO 8501-1:1988, surface
Surface roughness Rz = 40-70μm as mentioned in product datasheet, after preparation the surface shall be cleaned from loose dust and debris. Check Information sheet 1490 for more
Preparation: information and max. allowable soluble salt content.

SYSTEM INFORMATION * FC = Full Coat, TU = Touch Up, MC = Mist Coat, SC = Stripe coat, TR = Trowel/Scrape Coat
Product Shade Type of DFT µm WFT µm volume Theoretical Min. Overcoat Max. Overcoat Estimated Application Method
Ref. Name coat * solids % Spr.r. m2/ltr 1) at 20°C at 20°C volume [L] Brush Roller Spray
7702 SigmaZinc 102 HS r-brown FC 60 91 66 11.0 6 hrs See PDS 182 FALSE FALSE TRUE
6823 SigmaCover 410 grey FC 125 156 80 6.4 8hrs unlimited* 313 FALSE FALSE TRUE
7528 SigmaDur Gloss to be advice FC 50 89 56 11.2 12 hrs unlimited* 179 FALSE FALSE TRUE
0 0 FALSE FALSE FALSE
0 0 FALSE FALSE FALSE
Total Dry Flm Thickness (DFT): 235 µm

PRODUCT INFORMATION 2)
Product Curing Mixing Pot life [h] Touch dry Mixing Airless Spray specs Flash Application restrictions
Ref. Name Agent ratio B:H at 20°C at 20°C Thinner Orifice/inch Pressure in PSI Point [°C] Max RH% Min. substrate T [°C]
7702 SigmaZinc 102 HS amide 80:20 8 2 hrs 91-92 0.017-0.019 2130 B:29/H:26 80 5°C & dewpoint +3°C
6823 SigmaCover 410 amide 80:20 6 3 hrs 91-92 0.018-0.021 2800-3500 B:22/H:28 80 5°C & dewpoint +3°C
7528 SigmaDur Gloss isocyanate 88:12 6 1 hr 21-06 0.013 2800 B:26/H:42 80 -5°C & dewpoint +3°C

NOTES/REMARKS
T) For internal tank and pipe-coating specifications exposure (chemicals, pH, pressure, temperatures, cathodic protection etc) should be approved and mentioned on the specification, refer to
individual system sheets, check the requirement for hot cure and minimum required curing time before first service, use approved tank-coating work procedure. For this specification formal approval of
the technical service department is required, a TSD reference code and stamp will be added to all approved specifications, specifications are considered a DRAFT version if not stamped.
SS) The maximum acceptable water soluble salts on treated substrate prior to painting is 60mg/m² (chloride equivalent), see sheet 1490.

1) The spreading rate is theoretical, customer should add the appropriate wastage factor.
2) Please refer to the product technical datasheet for additional information. For explanation to product data sheets please refer to informationsheet 1411.
3) To avoid any confusion that may arise through translation into other languages, the English version of the Product Data, specification and PSGS will be the governing literature and must be referred to in case
of deviations with documentation in other languages.

Disclaimer:
This painting specification has been prepared to the best of our knowledge to ensure good workmanship. However, the responsibility for executing the work stays with the yard/ (sub) contractor. The role of our Technical Services
Representative is to provide onsite technical assistance/ advice. The presence and/ or the technical advice of our technical representatives shall not relieve the yard/ (sub) contractor and owners of their responsibility for correct
execution and quality assurance of the coating work and the Paint Manufacturer (Sigma) shall at all times be held harmless and indemnified against all third party claims.
Technical Services Department: (signature/stamp): template version 23-Nov-15 database version: 31-Oct-17

For additional information contact Technical Service Department (TSD) Tel: + 966 3 847 3100 / Fax + 966 3 847 1734
or PC Sales Tel:+966 3 847 1333 / Fax: +966-3 847 4209
Sigma Paints Saudi Arabia Ltd. Technical Specification
Kingdom of Saudi Arabia, Dammam Branch

Date: May 9, 2018 Project: #REF! Owner: SWCC


(Sub) Con: SWCC Location: KSA PSGS index 072-00196-REV02-18-1 System: 1
Area 1000 m²
Substrate type Carbon Steel carbon steel (blast Sa 3) FALSE Tank or pipe coating specification (internal)
Area TANK INTERNAL
description / (SHELL PLATE, BOTTOM PLATE, ROOF PLATE UNDERSIDE, INSIDE SURFACES OF NOZZLES & MANHOLES, EXTERNAL SURFACE OF STRUCTURALS)
Minimum TANK INTERNAL
Wash/degrease with fresh water (and if required detergent f.i. 0800 Sigma Paint Cleaner Degreaser), abrasive blast to minimum Sa 3 according to ISO 8501-1:1988, no remaining
Surface contamination shall be visible through magnification, substrate shall have a uniform metallic colour, surface roughness Rz = 30-75µm as mentioned in product datasheet, after preparation the
Preparation: surface shall be cleaned from loose dust and debris. Check Information sheet 1490 for more information and max. allowable soluble salt content.

SYSTEM INFORMATION * FC = Full Coat, TU = Touch Up, MC = Mist Coat, SC = Stripe coat, TR = Trowel/Scrape Coat
Product Shade Type of DFT µm WFT µm volume Theoretical Min. Overcoat Max. Overcoat Estimated Application Method
Ref. Name coat * see note σ solids % Spr.r. m2/ltr 1) at 20°C at 20°C volume [L] Brush Roller Spray
7417 SigmaCover 280- use for shop yel-green/r-brown FC 50 88 57 11.4 8 hrs See PDS 146 FALSE FALSE TRUE
7785 SigmaGuard CSF 585 lt blue, white FC 225 225 100 4.4 24 hrs 20 days 375 FALSE FALSE TRUE
7785 SigmaGuard CSF 585 lt blue, white FC 225 225 100 4.4 24 hrs 20 days 375 FALSE FALSE TRUE
0 0 FALSE FALSE FALSE
0 0 FALSE FALSE FALSE
Total Dry Flm Thickness (DFT): 500 µm
2)
PRODUCT INFORMATION
Product Curing Mixing Pot life [h] Touch dry Mixing Airless Spray specs Flash Application restrictions
Ref. Name Agent ratio B:H at 20°C at 20°C Thinner Orifice/inch Pressure in PSI Point [°C] Max RH% Min. substrate T [°C]
7417 SigmaCover 280- use for shop amide-adduct 80:20 8 1.5 hrs 91-92 0.018 2130 B:26/H:26 80 5°C & dewpoint +3°C
7785 SigmaGuard CSF 585 amine 77.5:22.5 1.5 5 hrs none 0.021 See PDS >65 80 10°C & dewpoint +3°C
7785 SigmaGuard CSF 585 amine 77.5:22.5 1.5 5 hrs none 0.021 See PDS >65 80 10°C & dewpoint +3°C

NOTES/REMARKS
σ1) Specifications below datasheet DFT may result in pinholes and require extra thinning, extra thinning can result in reduced sag resistance.
SF) Solvent free products have additional requirements regarding airless equipment and require extra care re. Potlife and WFT checks, please see datasheets.
1) The spreading rate is theoretical, customer should add the appropriate wastage factor.
2) Please refer to the product technical datasheet for additional information. For explanation to product data sheets please refer to informationsheet 1411.
3) To avoid any confusion that may arise through translation into other languages, the English version of the Product Data, specification and PSGS will be the governing literature and must be referred to in case
of deviations with documentation in other languages.

Disclaimer:
This painting specification has been prepared to the best of our knowledge to ensure good workmanship. However, the responsibility for executing the work stays with the yard/ (sub) contractor. The role of our Technical Services
Representative is to provide onsite technical assistance/ advice. The presence and/ or the technical advice of our technical representatives shall not relieve the yard/ (sub) contractor and owners of their responsibility for correct
execution and quality assurance of the coating work and the Paint Manufacturer (Sigma) shall at all times be held harmless and indemnified against all third party claims.
template version 11-Oct-16 database version: 8-Feb-18
Technical Services Department: (signature/stamp):

For additional information contact Technical Service Department (TSD) Tel: + 966 3 847 3100 / Fax + 966 3 847 1734
or PC Sales Tel:+966 3 847 1333 / Fax: +966-3 847 4209
Sigma Paints Saudi Arabia Ltd. Technical Specification
Kingdom of Saudi Arabia, Dammam Branch

Date: December 24, 2017 Project: PP12- SEC Owner:


(Sub) Con: Ayash steel Location: KSA PSGS index 072-00177-17-3 System: 3
Area 1000 m²
Substrate type Carbon Steel carbon steel (blast Sa 2.5) FALSE Tank or pipe coating specification (internal)
Area description BOTTOM PLATE UNDERSIDE system
/ exposure
Minimum Wash/degrease with fresh water (and if required detergent f.i. 0800 Sigma Paint Cleaner Degreaser), abrasive blast to minimum Sa 2½ according to ISO 8501-1:1988, surface roughness Rz =
Surface 35-50µm unless otherwise mentioned in product datasheet, after preparation the surface shall be cleaned from loose dust and debris. Check Information sheet 1490 for more information and
Preparation: max. allowable soluble salt content.

SYSTEM INFORMATION * FC = Full Coat, TU = Touch Up, MC = Mist Coat, SC = Stripe coat, TR = Trowel/Scrape Coat
Product Shade Type of DFT µm WFT µm volume Theoretical Min. Overcoat Max. Overcoat Estimated Application Method
Ref. Name coat * solids % Spr.r. m2/ltr 1) at 20°C at 20°C volume [L] Brush Roller Spray
3307 Sigma C200a Coal Tar black FC 200 256 78 3.9 6 hrs 5 days 427 FALSE FALSE TRUE
3307 Sigma C200a Coal Tar black FC 200 256 78 3.9 6 hrs 5 days 427 FALSE FALSE TRUE
0 0 FALSE FALSE FALSE
0 0 FALSE FALSE FALSE
0 0 FALSE FALSE FALSE
Total Dry Flm Thickness (DFT): 400 µm
2)
PRODUCT INFORMATION
Product Curing Mixing Pot life [h] Touch dry Mixing Airless Spray specs Flash Application restrictions
Ref. Name Agent ratio B:H at 20°C at 20°C Thinner Orifice/inch Pressure in PSI Point [°C] Max RH% Min. substrate T [°C]
3307 Sigma C200a Coal Tar amide 86:14 6 4 hrs 21-06 0.019-0.023 2500-2700 B:27/H:25 80 10°C & dewpoint +3°C
3307 Sigma C200a Coal Tar amide 86:14 6 4 hrs 21-06 0.019-0.023 2500-2700 B:27/H:25 80 10°C & dewpoint +3°C

NOTES/REMARKS
1) The spreading rate is theoretical, customer should add the appropriate wastage factor.
2) Please refer to the product technical datasheet for additional information. For explanation to product data sheets please refer to informationsheet 1411.
3) To avoid any confusion that may arise through translation into other languages, the English version of the Product Data, specification and PSGS will be the governing literature and must be referred to in case
of deviations with documentation in other languages.

Disclaimer:
This painting specification has been prepared to the best of our knowledge to ensure good workmanship. However, the responsibility for executing the work stays with the yard/ (sub) contractor. The role of our Technical Services
Representative is to provide onsite technical assistance/ advice. The presence and/ or the technical advice of our technical representatives shall not relieve the yard/ (sub) contractor and owners of their responsibility for correct
execution and quality assurance of the coating work and the Paint Manufacturer (Sigma) shall at all times be held harmless and indemnified against all third party claims.
template version 11-Oct-16 database version: 28-Jun-17
Technical Services Department: (signature/stamp):

For additional information contact Technical Service Department (TSD) Tel: + 966 3 847 3100 / Fax + 966 3 847 1734
or PC Sales Tel:+966 3 847 1333 / Fax: +966-3 847 4209