Nyfgby 2 X (1.5-300) MM 0.6/1 KV
Nyfgby 2 X (1.5-300) MM 0.6/1 KV
NYFGbY 22xx(1.5-300)
(1.5-300) mm²
mm² 0.6/1
0.6/1 kV kV
Cu / PVC / SFWA / PVC
(Copper Conductor, PVC Insulated, Galvanized Steel Flat Wire Armor, PVC Sheathed)
Standard Specification : IEC 60502-1
Construction Data
Application :
Nom. Overall Cable Copper Conductor
For installation in the ground, indoors, cable
Cross Diameter Weight trunking and outdoors if increased mechanical
Section PVC Insulation
protection is required or where high-pulling
Area approx. approx. stresses may occur during installation or
PVC Inner Sheath
mm² mm kg/km operation.
1.5 17.9 611 Special Features on Request : Galvanized Steel Flat Wire Armor
• Fire Resistance Galvanized Steel Tape
2.5 18.0 630
• Oil Resistance PVC Sheath
4 17.8 648 • UV Resistance
6 18.1 687 • Flame Retardant Cat. A, B, C
• Flame Retardant Non Category
10 20.5 881
• Heat Resistance
16 22.5 1,085 • Anti Termite
25 25.5 1,428 • Anti Rodent
• Low Smoke Zero Halogen
35 27.5 1,753
50 31.0 2,120
70 35.0 2,716
Note :
95 39.5 3,528 Conductor Shape
120 43.0 4,177 1.5 - 10 sqmm supplied in solid (re) or non compacted circular stranded (rm)
conductor shape
150 47.0 5,012 16 sqmm supplied in non compacted circular stranded (rm) conductor shape
185 52.0 6,116 25 - 300 sqmm supplied in compacted circular stranded (cm) conductor shape
240 58.0 7,695
Standard Packing
300 64.0 9,384 1.5 - 95 sqmm supplied in wooden drum @ 1000 m
120 - 300 sqmm will be suplied in wooden drum on available length
Length Tolerance per drum ± 2%
Electrical Data
Conductor Inductance Current - Carrying Short
Capacity circuit current
Nom. DC AC
at 30°C * at
Cross Resistance Resistance 1 sec
Sect. at 20°C at 70°C in air in ground
www.kmi.co.id
PT KMI Wire and Cable Tbk reserves the right to change the data content without prior notification
NYFGbY
NYFGbY 33xx(1.5-300)
(1.5-300) mm²
mm² 0.6/1
0.6/1 kV kV
Cu / PVC / SFWA / PVC
(Copper Conductor, PVC Insulated, Galvanized Steel Flat Wire Armor, PVC Sheathed)
Standard Specification : IEC 60502-1
Construction Data
Application :
Nom. Overall Cable Copper Conductor
For installation in the ground, indoors, cable
Cross Diameter Weight
trunking and outdoors if increased mechanical
Section protection is required or where high-pulling
PVC Insulation
Area approx. approx. stresses may occur during installation or
operation. PVC Inner Sheath
mm² mm kg/km
Galvanized Steel Flat Wire Armor
1.5 17.8 620 Special Features on Request : Galvanized Steel Tape
2.5 18.0 648 • Fire Resistance
• Oil Resistance PVC Sheath
4 18.0 681 • UV Resistance
6 19.0 789 • Flame Retardant Cat. A, B, C
• Flame Retardant Non Category
10 21.5 997 • Heat Resistance
16 23.5 1,280 • Anti Termite
• Anti Rodent
25 27.0 1,709 • Low Smoke Zero Halogen
35 29.5 2,123
50 32.0 2,444
Note :
70 36.0 3,217
Conductor Shape
95 40.5 4,171 1.5 - 10 sqmm supplied in solid (re) or non compacted circular stranded (rm)
conductor shape
120 43.5 4,957
16 sqmm supplied in non compacted circular stranded (rm) conductor shape
150 48.0 6,011 25 - 35 sqmm supplied in compacted circular stranded (cm) conductor shape
50 - 300 sqmm supplied in sector shaped stranded (sm) conductor
185 52.5 7,319
240 59.0 9,324 Standard Packing
1.5 - 70 sqmm supplied in wooden drum @ 1000 m
300 64.5 11,344
95 - 300 sqmm will be suplied in wooden drum on available length
Length Tolerance per drum ± 2%
Electrical Data
Conductor Inductance Current - Carrying Short
Capacity circuit current
Nom. DC AC
at 30°C * at
Cross Resistance Resistance 1 sec
Sect. at 20°C at 70°C in air in ground
www.kmi.co.id
PT KMI Wire and Cable Tbk reserves the right to change the data content without prior notification
NYFGbY
NYFGbY 44xx(1.5-300)
(1.5-300) mm²
mm² 0.6/1
0.6/1 kV kV
Cu / PVC / SFWA / PVC
(Copper Conductor, PVC Insulated, Galvanized Steel Flat Wire Armor, PVC Sheathed)
Standard Specification : IEC 60502-1
Construction Data
Application :
Nom. Overall Cable
For installation in the ground, indoors, cable
Cross Diameter Weight Copper Conductor
trunking and outdoors if increased mechanical
Section protection is required or where high-pulling PVC Insulation
Area approx. approx. stresses may occur during installation or
operation. PVC Inner Sheath
mm² mm kg/km
1.5 17.9 630 Special Features on Request : Galvanized Steel Flat Wire Armor
2.5 18.0 662 • Fire Resistance Galvanized Steel Tape
• Oil Resistance
4 19.0 773 PVC Sheath
• UV Resistance
6 20.5 912 • Flame Retardant Cat. A, B, C
• Flame Retardant Non Category
10 23.0 1,174
• Heat Resistance
16 25.5 1,520 • Anti Termite
25 29.0 2,053 • Anti Rodent
• Low Smoke Zero Halogen
35 32.0 2,584
50 37.5 3,173
70 40.5 4,087 Note :
95 46.5 5,359 Conductor Shape
120 50.5 6,459 1.5 - 10 sqmm supplied in solid (re) or non compacted circular stranded (rm)
conductor shape
150 56.5 7,868 16 sqmm supplied in non compacted circular stranded (rm) conductor shape
185 61.0 9,556 25 - 35 sqmm supplied in compacted circular stranded (cm) conductor shape
50 - 300 sqmm supplied in sector shaped stranded (sm) conductor
240 68.0 12,138
300 74.5 14,773 Standard Packing
1.5 - 50 sqmm supplied in wooden drum @ 1000 m
70 - 300 sqmm will be suplied in wooden drum on available length
Length Tolerance per drum ± 2%
Electrical Data
Conductor Inductance Current - Carrying Short
Capacity circuit current
Nom. DC AC
at 30°C * at
Cross Resistance Resistance 1 sec
Sect. at 20°C at 70°C in air in ground
www.kmi.co.id
PT KMI Wire and Cable Tbk reserves the right to change the data content without prior notification
NYFGbY
NYFGbY 55xx(1.5-50)
(1.5-50) mm²
mm² 0.6/1
0.6/1 kV kV
Cu / PVC / SFWA / PVC
(Copper Conductor, PVC Insulated, Galvanized Steel Flat Wire Armor, PVC Sheathed)
Standard Specification : IEC 60502-1
Construction Data
Application : PVC Filler
Nom. Overall Cable
For installation in the ground, indoors, cable Copper Conductor
Cross Diameter Weight
trunking and outdoors if increased mechanical
Section protection is required or where high-pulling PVC Insulation
Area approx. approx. stresses may occur during installation or
operation. PVC Inner Sheath
mm² mm kg/km
Galvanized Steel Flat Wire Armor
1.5 17.8 642 Special Features on Request :
Galvanized Steel Tape
• Fire Resistance
2.5 17.9 682 • Oil Resistance
PVC Sheath
4 20.5 891 • UV Resistance
• Flame Retardant Cat. A, B, C
6 22.0 1,056 • Flame Retardant Non Category
• Heat Resistance
10 24.5 1,391 • Anti Termite
16 27.5 1,778 • Anti Rodent
• Low Smoke Zero Halogen
25 32.0 2,463
35 35.0 3,106
50 40.0 3,904 Note :
Conductor Shape
1.5 - 10 sqmm supplied in solid (re) or non compacted circular stranded (rm)
conductor shape
16 sqmm supplied in non compacted circular stranded (rm) conductor shape
25 - 50 sqmm supplied in compacted circular stranded (cm) conductor shape
Standard Packing
1.5 - 50 sqmm supplied in wooden drum @ 1000 m
Length Tolerance per drum ± 2%
Electrical Data
Conductor Inductance Current - Carrying Short
Capacity circuit current
Nom. DC AC
at 30°C * at
Cross Resistance Resistance 1 sec
Sect. at 20°C at 70°C in air in ground
www.kmi.co.id
PT KMI Wire and Cable Tbk reserves the right to change the data content without prior notification