Guide
Casio & Datacap
Programming 9 - 14
Network Commands 15 - 16
2
SE Series Datacap Setup
In order to interface the Datacap terminal to the SE Series a new IPL might need
to be loaded into the machine. The IPL naming for these machines will be
SE3000. . The IPL is loaded through a SD Card and the slot for the card is
located on the left hand side of the machine. Opening the small door on the left
side of the machine will expose the SD Card slot. The IPL file can be requested
from Casio America or downloaded from the dealer section of the
www.casio4business.com web site.
Through a PC load the TE3000.IPL file into the root directory of the SD card.
Once the IPL is on the card it can be loaded into a machine through a key
sequence discussed afterwards.
The Casio cash register has a seven (7) position mode lock switch located below
the operator display as shown below:
There are two different types of keys, operator (grey) and a program key (black).
The program key will turn to any position in the mode lock. The operator key will
only go to OFF, REG and X positions. The steps discussed in this manual will
require the program (black) key and the key to be in the PGM position. Starting
from the OFF position turn the program key counter clock wise down to PGM.
The following section will outline the use of the SD card for upgrading the cash
register’s software (which is called an IPL- Initial Program Load) and backing
up/loading customer programs.
3
Backing up Customer Program
1) Turning the Mode Lock key to the PGM position will display the following
screen:
2) Using the Down Arrow key or Enter highlight the SDCard line and
depressing the CA/AMT TEND key will display the SD Card options as
following screen shows:
3) Make sure there is an card in the SD Card slot on the left hand side of the
machine and depress the CA/AMT TEND key with the Backup line
highlighted and the machine will proceed to back up the program
4) When the program back up is completed depress the Subtotal key twice to
return to the main program screen
4
How to Load the IPL from SD Card to ECR
8) At this time the machine will proceed to load the IPL off the RAC Card
9) Upon IPL uploading completion the following screen will appear:
INIT
00000000000000
11) Enter
the initialization code of “2DD40” and depress SUBTOTAL - DD= # of
departments
SE-C3500/450 enter 27240 SE-S3000 enter 23040
5
Load Customer Program from Card to Machine
2) Using the Down Arrow key or Enter highlight the SD Card line and
depressing the CA/AMT TEND key will display the SD Card options as
following screen shows:
6
Connecting Your Equipment
NOTE: Before connecting anything to the cash register unplug the cash
register’s power source. Connecting equipment together while power is still
being supplied can result in equipment damage (component & equipment
failure).
1) On the right hand side of your Casio cash register where power cord
comes out there is a cover. Between the cash drawer and the cabinet
there is a small slot, put your fingers in this slot to pull the cover off. Once
the cover off you will see the following:
2) Removing the cover exposes the Communication ports. There are two (2)
DB 9, male connector COM ports that are labeled COM 1 (PC) and COM
2 (scanner). The Datacap terminal will be connected to COM 1, the cable
with the 9 pin connector (see sample COM port picture below) will plug
into this connection.
7
3) Take the other end of the cable, an 8 pin din round connector and plug it
into the round connector in the back of the Datacap credit device.
NOTE: Please be careful when plugging the connector in, do not force, the
cable connector and the connector itself are keyed. Carefully examine and line
up the pins and key of both the cable and connector before plugging in.
4) Next plug the Datacap power supply into the power connector in the back
of the credit device (shown below) but do not plug in the power at this
time.
5) When all the cables are connected, turn ON the power for both your Casio
cash register and the Datacap credit card device (we strongly suggest that
both devices be plugged into the same power strip so that both device’s
power come on at the same time)
8
Programming
The following pages will contain the Electronic Payment Processing setup
parameters for the Casio ECR’s. The ECR’s COM port must be configured in
order for the ECR to communicate with the Datacap device and process
Credit/Debit/Gift card transactions.
SE Series
SE-C3500 SE-S3000
The following pages will contain the Electronic Payment Processing setup
parameters for the Casio ECR’s to communicate and operate with the Datacap
device.
9
Program Communication Port
1) Turn the mode lock key to the PGM position and the following screen
will appear:
2) Depress the Enter key to page down to the System Setting option and
depress the CAAMT Tend key
3) The following screen will appear:
4) The first item to program is the communication port that the PAX
device is connected to (COM #1 or COM #2).
5) Enter 3 at this point and depress the Subtotal key
10
6) Enter 198 (for Com port #1) or 298 (for COM #2) and depress the
Subtotal key
7) Enter the one of the Program values below, depress the Cash Key
and then the Subtotal Key
NOTE: Upon the Subtotal key depression the cash register will go out the
COM port designated above and look for the credit card device. The cash
register will display “INITIALIZING”.
If the cash register connects with the credit card device then “Initialized”
message will appear.
If the cash register fails to connect with the credit card device the message
“Init Fail!” message will appear.
11
Tender Key Programming
SE-S3000 Keyboard
12
Key Operation to Assign Function Keys to the Keyboard
NOTE: The three (3) online processing tender keys above are the
CREDIT, CHECK and CHARGE keys
2) In the PGM 4 mode entering the three (3) digit function code and
then depress the desired key location will assign this function to
that location (repeat this step for each key to be assigned to the
keyboard).
3) When the key assignments have been completed depress the
Subtotal key
13
Example - To program the standard credit function key to be a credit card
electronic payment key:
PGM Mode
Enter 3 and depress Subtotal
Enter 10000 and depress the CREDIT function key
Depress Subtotal to end the process
Currently, most of the basic EFT General Function Programming options are in
PGM 3 - record 2222.
Program
Description Choice Code
Credit Chit Amount (if authorized amount is less than this (0-99) D6-D5
$, no chit)
Allow “Partial Authorization” for Gift Card a) 1=”Yes” D4
Ask for Cashier # during Charge TIP a) 1=”Yes”
Print a chit for the Charge TIP b) 2=”Yes” D3
Print TIP line on EFT receipt c) 4=”Yes” (a+b+c)
Currently Not Used 0 D2
TX Port used a) 1=”Yes” D1
14
Network Commands
The network commands are key sequences designed to communicate with the
Datacap device for various functions. Below is the list of commands and key
sequences:
Executing in X or Z position turn the Mode Lock key to that position. Enter the
desired command below followed by the CASH key depression.
15
VOID/POST AUTHORIZATION – this has a dual function,
first it allows you to VOID a transaction in the batch file,
secondly it allows you to input transactions that were post
authorized (authorization that was done if the credit card
system was down).
CHECK GIFT CARD BALANCE – allows you to check the
balance remaining a customer’s gift card.
Special Commands
4311 = Dial In
4312 = Dial Out
4313 = List Installed Networks
4314 = Local Totals
4315 = Clear Batch