Professional Documents
Culture Documents
MLFB-Ordering data
6SL3210-1KE21-7UP1
Figure similar
Number of phases 3 AC
Offset factor cos φ 0.95
Technical data are subject to change! There may be discrepancies between calculated and rating plate values.
Page 1 of 3 Generated Wed Nov 11 10:43:26 CET 2020
Data sheet for SINAMICS G120C
MLFB-Ordering data
6SL3210-1KE21-7UP1
Figure similar
Size FSB
Connections
Net weight 2.30 kg (5.07 lb) Signal cable
Width 100 mm (3.94 in) Conductor cross-section 0.15 ... 1.50 mm² (AWG 24 ... AWG 16)
Inputs / outputs Conductor cross-section 4.00 ... 6.00 mm² (AWG 12 ... AWG 10)
Switching level: 0→1 11 V Conductor cross-section 4.00 ... 6.00 mm² (AWG 12 ... AWG 10)
0→1 4V
1→0 1.6 V
Analog outputs
1 motor temperature sensor input, sensors that can be connected: PTC, KTY
and Thermo-Click, accuracy ±5 °C
Technical data are subject to change! There may be discrepancies between calculated and rating plate values.
Page 2 of 3 Generated Wed Nov 11 10:43:26 CET 2020
Data sheet for SINAMICS G120C
MLFB-Ordering data
6SL3210-1KE21-7UP1
Figure similar
Efficiency class
IE2
I
175.0 W (1.53 %) 200.0 W (1.75 %) 241.0 W (2.11 %)
100%
50% 90% f
The percentage values show the losses in relation to the rated apparent power of the converter.
The diagram shows the losses for the points (as per standard EN 50598) of the relative torque
generating current (I) over the relative motor stator frequency(f). The values are valid for the basic
version of the converter without options/components.
*converted values
Technical data are subject to change! There may be discrepancies between calculated and rating plate values.