You are on page 1of 1

KEY PLAN

NORTH

WEST EAST

SOUTH
(MAKKAH)
.55

24

LEGEND
E-01 SOUTH ELEVATION 1:100 E-02 WEST ELEVATION 1:100
580.290 = 0.00 AMSL

-23.85 F.F.L.
29' 30' 31' 32' 33' 34' 35' Q' R' S' T' U' Elevations - mt - finishing floor level
370 3200 7325 10295 10525 370
370 6160 5400 5400 5400 4475 8545 2419 1000
Linear dimensions - mm

S-01
+15.80 F.P.L. +15.80 F.P.L. 21
Section lines - see section drawings
ROOF LEVEL M-AOW-3E2TS0-CAEW-EDR-192001
ROOF LEVEL

FINISHING TAGS
finishing code - see finishing schedule report
REN-11
M-AOW-3E2TS0-CAIF-ESH-190005

DOOR/WINDOWS TAGS
door code - see door schedule report & drawings
FD-000 M-AOW-3E2TS0-CAID-ESH-190010
M-AOW-3E2TS0-CAST-EDR-192016
+10.65 F.F.L. +10.65 F.F.L. window code - see window drawings
FW-000
MEP/CHILLER PLANT MEP/CHILLER PLANT
M-AOW-3E2TS0-CAST-EDR-192016
LEVEL LEVEL
DETAIL TAGS

2
-0 0
2
1

2
-00
D-01

-00

-00
Detail number

FW
FW
FW

FW

1
-00
1

1
2

1
-00

-00
-00

-00

-00

FW
2
FW

FW
FW

FW

FW

1
-00
See note "x" for drawing number

-00
X

FW

2
1

FW

00
-0 0
2

-
00

FW
FW

-00
-
FW

FW
1

1
1

2
-00

-00

-00

-00
-00

-00
1

2
FW

FW

FW

FW
FW

1
2

1
-00

-00

-00

-00

-00

FW

-00
-00

-00

-00

-00
FW

FW

FW

FW

FW

FW
FW

FW

FW

FW
FACADE FINISHES
2
-00
FW

EWS-21
+5.25 F.F.L. +5.25 F.F.L. Engineered Stone Cladding
ref: EWS-81 (finish brushed)
FIRST FLOOR LEVEL FIRST FLOOR LEVEL
2

2
2
-00

-00

-00
-00
FW

FW

FW
FW

1
1

2
-00

-00
-00

-00

-00
EWS-81
FW

FW
FW

FW

FW
EWS-81

1
EWS-81 EWS-81 Engineered Stone Cladding

-00
2
-00

FW
FW

ref: EWS-81 (finish fine bush hammered)

2
-00
EWS-21

FW
1
1

-00
-00

2
FW
FW

1
-00

-00
FW

FW
FD-007 FD-007 FD-011
Engineered Stone Cladding
ref: EWS-81 (finish bush hammered)
+1.10 F.F.L. +0.90 F.F.L.
+0.60 F.F.L. +0.59 F.F.L. +0.59 F.F.L. +0.60 F.F.L. +0.59 F.F.L. +0.59 F.F.L. +0.59 F.F.L. +0.60 F.F.L.
GROUND FLOOR LEVEL WINDOW
GROUND FLOOR LEVEL
DRS-12 DRS-12 DRS-12 ref: EWS-21

D-03 D-03 D-03


8 8 8
(similar)

E-03 NORTH ELEVATION 1:100 E-04 EAST ELEVATION 1:100

35' 34' 33' 32' 31' 30' 29' S' Q'


U' T' R'
2419 8545 4475 5400 5400 5400 6160 370
370 10525 10295 7325 3200 370

+15.80 F.P.L. +15.80 F.P.L.


ROOF LEVEL ROOF LEVEL

NOTES
+10.65 F.F.L. +10.65 F.F.L. 1.This drawing has to be read contemporary with structural and plant
MEP/CHILLER PLANT
design (drawings and specifications)
MEP/CHILLER PLANT
LEVEL LEVEL 2. In case of discordance between written dimensions and directly
measured, dimensions, written dimensions are always predominant.
3. In case of discordance between different design documents, more
1

1
00

-00
2
-

detailed drawings have to be predominant (in order scale 1:1, 1:5, 1:20,
FW

FW
00

1
1

1
-
FW

-00
-00

-00

1:50 etc).
1
2

FW
FW

FW

00
00

-
-

FW
FW

4.This drawing has to be read contemporary with site survey information


1

provided. The accuracy of all information provided is subject to review upon


00

00

00

2
-

-
FW

FW

FW

-00

receipt of further surveys, visual inspection on site and measurement


FW

1
-00

-00
1

setting out.
-00

EWS-21
FW

FW
FW

EWS-81
5. It is the contractor and subcontractor responsibility to check all
dimensions prior to commencing any work and to satisfy themselves that
+5.25 F.F.L. EWS-81 the works comply with the architects dimensions shown in this drawing.
+5.25 F.F.L.
6. All drawings to be read in conjunction with all Architectural, MEP,
FIRST FLOOR LEVEL FIRST FLOOR LEVEL Structural stage reports.
1
00

1
2

EWS-81
-
FW

-00

-00
-00

7. Refer to drawing M-AOW-3E2TS0-CAFS-EDR-192018


2
FW

FW
FW

00
1

2
2

-
FW

8. Refer to drawing M-AOW-3E2TS0-CAST-EDR-192016


-00

-00

-00
-00

EWS-81
FW

FW

FW
FW

2
-00
2
2

FW
-00
-00

FD-007
FW
FW

Refer to Ext. Ablution drawing:


M-AOW-3E2TS0-CLFU-EDR-191017
FD-011
Refer to
Ext. Ablution drawing:
M-AOW-3E2TS0-CLFU-EDR-191017
+1.53 +1.48 F.F.L. +1.50 F.F.L. +1.52 F.F.L.
+1.17 F.F.L. D 05/03/2018 ISSUED_FOR_APPROVAL_(IFA) M.F.
+1.10 F.F.L.
DRS-12
+0.60 F.F.L. +0.60 F.F.L. +0.60 F.F.L. +0.60 F.F.L. C 10/06/2017 ISSUED_FOR_APPROVAL_(IFA) M.F.
DRS-12
GROUND FLOOR LEVEL GROUND FLOOR LEVEL B 31/10/2016 ISSUED_FOR_APPROVAL_(IFA) M.F.
EWS-771

A 30/06/2016 ISSUED_FOR_APPROVAL_(IFA) M.F.


D-03 D-02 D-01 P1 20/11/2015 INTRA_AND_INTERDISCIPLINARY_CHECKS_(IDC) L.C.
E-01
8 8 8 REV. DATE DESCRIPTION APP.

7 PROJECT

RIYADH METRO PROJECT


PACKAGE 2. LINE 3

ARRIYADH NEW MOBILITY

+ +
ORIGINATOR CHECK REVIEW APPROVAL
S.CITRONE M.BECKERT L.CREMONESI M.FAGGIANI
DATE SCALES ORIGINAL SIZE A0
A0= 1:100
MARCH 2018 A3=
0 250 500

SUBJECT TITLE
90% DETAILED ARCHITECTURAL DESIGN
3E 2-1F 7 DOWNTOWN STATION
MOSQUE ELEVATIONS

ANM DRAWING REFERENCE NUMBER REVISION SHEET


M-AOW-3E2TS0-CAEW-EDR-192002 D 1 of 1

ALTERNATE DOCUMENT NUMBER REVISION SHEET


M-AOW-3E2TS0-CAEW-EDR-192002 D 1 of 1